Cargando…

Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair

Ethyl glucuronide (EtG) is a minor, non-oxidative ethanol metabolite detectable in several matrices for specific periods of time. In recent years, quantification of EtG in hair has been established as the most reliable biomarker for long-term alcohol consumption, with the Society of Hair Testing off...

Descripción completa

Detalles Bibliográficos
Autores principales: Mattia, Alessandro, Moschella, Clementina, David, Maria Chiara, Fiore, Marco, Gariglio, Sara, Salomone, Alberto, Vincenti, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9013907/
https://www.ncbi.nlm.nih.gov/pubmed/35444998
http://dx.doi.org/10.3389/fchem.2022.858205
_version_ 1784688099730653184
author Mattia, Alessandro
Moschella, Clementina
David, Maria Chiara
Fiore, Marco
Gariglio, Sara
Salomone, Alberto
Vincenti, Marco
author_facet Mattia, Alessandro
Moschella, Clementina
David, Maria Chiara
Fiore, Marco
Gariglio, Sara
Salomone, Alberto
Vincenti, Marco
author_sort Mattia, Alessandro
collection PubMed
description Ethyl glucuronide (EtG) is a minor, non-oxidative ethanol metabolite detectable in several matrices for specific periods of time. In recent years, quantification of EtG in hair has been established as the most reliable biomarker for long-term alcohol consumption, with the Society of Hair Testing offering cut-off values for assessment of both abstinence and heavy drinking. Instrumental constrains and wide inter- and intra-laboratory variability represent the ultimate barriers to widespread acceptance of hair EtG determination in the forensic context. In this study, a new analytical method for hair EtG based on gas chromatographic (GC) separation, electron impact (EI) ionization, and tandem mass spectrometry (MS/MS) detection was developed and validated. At the same time, several parameters for sample pretreatment and instrumental analysis were optimized using real hair samples obtained from different drinking subjects. A full-factorial design-of-experiment approach included procedures for hair washing, pulverization, and extraction. Rigorous multi-step washing proved not to reduce the EtG content extracted in the subsequent sample incubation. Hair pulverization with a ball mill significantly improved the EtG extraction from the keratin matrix and allowed us to reduce the time needed for the subsequent extraction step, without affecting the extraction recovery. The hair extract was derivatized with N-methyl-N-(trimethylsilyl)-trifluoroacetamide. Upon electron impact ionization of the EtG-TMS derivative, triple quadrupole mass analyzers were operated in the selected reaction monitoring (SRM) mode using the fragment m/z 405 as the precursor ion (m/z 410 for the EtG-D5 internal standard), the transitions m/z 405 → 359 and m/z 410 → 359 for quantitation, and m/z 405 → 331 and m/z 405 → 287 for qualification/confirmation, all at 10 V collision energy. The final method was fully validated and then applied to 25 real hair samples. The calibration curve proved linear between 6 and 60 pg/mg. The limit of detection (LOD) was 4 pg/mg. Intra- and inter-assay precision and accuracy tests showed a variability and bias close to 15% or lower over the entire calibration range. The new method is routinely applied in the Italian State Police’s toxicology laboratory for hair analyses addressed to exclude excessive alcohol drinking and verify the psycho-physical requirements of the personnel.
format Online
Article
Text
id pubmed-9013907
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90139072022-04-19 Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair Mattia, Alessandro Moschella, Clementina David, Maria Chiara Fiore, Marco Gariglio, Sara Salomone, Alberto Vincenti, Marco Front Chem Chemistry Ethyl glucuronide (EtG) is a minor, non-oxidative ethanol metabolite detectable in several matrices for specific periods of time. In recent years, quantification of EtG in hair has been established as the most reliable biomarker for long-term alcohol consumption, with the Society of Hair Testing offering cut-off values for assessment of both abstinence and heavy drinking. Instrumental constrains and wide inter- and intra-laboratory variability represent the ultimate barriers to widespread acceptance of hair EtG determination in the forensic context. In this study, a new analytical method for hair EtG based on gas chromatographic (GC) separation, electron impact (EI) ionization, and tandem mass spectrometry (MS/MS) detection was developed and validated. At the same time, several parameters for sample pretreatment and instrumental analysis were optimized using real hair samples obtained from different drinking subjects. A full-factorial design-of-experiment approach included procedures for hair washing, pulverization, and extraction. Rigorous multi-step washing proved not to reduce the EtG content extracted in the subsequent sample incubation. Hair pulverization with a ball mill significantly improved the EtG extraction from the keratin matrix and allowed us to reduce the time needed for the subsequent extraction step, without affecting the extraction recovery. The hair extract was derivatized with N-methyl-N-(trimethylsilyl)-trifluoroacetamide. Upon electron impact ionization of the EtG-TMS derivative, triple quadrupole mass analyzers were operated in the selected reaction monitoring (SRM) mode using the fragment m/z 405 as the precursor ion (m/z 410 for the EtG-D5 internal standard), the transitions m/z 405 → 359 and m/z 410 → 359 for quantitation, and m/z 405 → 331 and m/z 405 → 287 for qualification/confirmation, all at 10 V collision energy. The final method was fully validated and then applied to 25 real hair samples. The calibration curve proved linear between 6 and 60 pg/mg. The limit of detection (LOD) was 4 pg/mg. Intra- and inter-assay precision and accuracy tests showed a variability and bias close to 15% or lower over the entire calibration range. The new method is routinely applied in the Italian State Police’s toxicology laboratory for hair analyses addressed to exclude excessive alcohol drinking and verify the psycho-physical requirements of the personnel. Frontiers Media S.A. 2022-04-04 /pmc/articles/PMC9013907/ /pubmed/35444998 http://dx.doi.org/10.3389/fchem.2022.858205 Text en Copyright © 2022 Mattia, Moschella, David, Fiore, Gariglio, Salomone and Vincenti. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Mattia, Alessandro
Moschella, Clementina
David, Maria Chiara
Fiore, Marco
Gariglio, Sara
Salomone, Alberto
Vincenti, Marco
Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title_full Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title_fullStr Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title_full_unstemmed Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title_short Development and Validation of a GC-EI-MS/MS Method for Ethyl Glucuronide Quantification in Human Hair
title_sort development and validation of a gc-ei-ms/ms method for ethyl glucuronide quantification in human hair
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9013907/
https://www.ncbi.nlm.nih.gov/pubmed/35444998
http://dx.doi.org/10.3389/fchem.2022.858205
work_keys_str_mv AT mattiaalessandro developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT moschellaclementina developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT davidmariachiara developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT fioremarco developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT garigliosara developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT salomonealberto developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair
AT vincentimarco developmentandvalidationofagceimsmsmethodforethylglucuronidequantificationinhumanhair