Cargando…

Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker

Despite the use of near-infrared thoracoscopy with intravenous indocyanine green, intraoperative assessment of the surgical margin for the resection of non-palpable tumors located near the intersegmental plane requires highly advanced surgical skill for the prevention of local recurrence. Because th...

Descripción completa

Detalles Bibliográficos
Autores principales: Yutaka, Yojiro, Ohsumi, Akihiro, Nakajima, Daisuke, Hamaji, Masatsugu, Menju, Toshi, Date, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9016051/
https://www.ncbi.nlm.nih.gov/pubmed/35064473
http://dx.doi.org/10.1007/s11748-021-01762-7
_version_ 1784688445946331136
author Yutaka, Yojiro
Ohsumi, Akihiro
Nakajima, Daisuke
Hamaji, Masatsugu
Menju, Toshi
Date, Hiroshi
author_facet Yutaka, Yojiro
Ohsumi, Akihiro
Nakajima, Daisuke
Hamaji, Masatsugu
Menju, Toshi
Date, Hiroshi
author_sort Yutaka, Yojiro
collection PubMed
description Despite the use of near-infrared thoracoscopy with intravenous indocyanine green, intraoperative assessment of the surgical margin for the resection of non-palpable tumors located near the intersegmental plane requires highly advanced surgical skill for the prevention of local recurrence. Because the demarcation line is limited to the pleural surface, to overcome uncertainty in tumor palpation for deeply located small-sized lesions, other supplemental localization techniques have been proposed. Here, we present a novel surgical technique using radiofrequency identification markers for intraoperative assessment of the lateral surgical margin in segmentectomy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11748-021-01762-7.
format Online
Article
Text
id pubmed-9016051
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Nature Singapore
record_format MEDLINE/PubMed
spelling pubmed-90160512022-05-02 Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker Yutaka, Yojiro Ohsumi, Akihiro Nakajima, Daisuke Hamaji, Masatsugu Menju, Toshi Date, Hiroshi Gen Thorac Cardiovasc Surg How to Do It Despite the use of near-infrared thoracoscopy with intravenous indocyanine green, intraoperative assessment of the surgical margin for the resection of non-palpable tumors located near the intersegmental plane requires highly advanced surgical skill for the prevention of local recurrence. Because the demarcation line is limited to the pleural surface, to overcome uncertainty in tumor palpation for deeply located small-sized lesions, other supplemental localization techniques have been proposed. Here, we present a novel surgical technique using radiofrequency identification markers for intraoperative assessment of the lateral surgical margin in segmentectomy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11748-021-01762-7. Springer Nature Singapore 2022-01-22 2022 /pmc/articles/PMC9016051/ /pubmed/35064473 http://dx.doi.org/10.1007/s11748-021-01762-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle How to Do It
Yutaka, Yojiro
Ohsumi, Akihiro
Nakajima, Daisuke
Hamaji, Masatsugu
Menju, Toshi
Date, Hiroshi
Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title_full Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title_fullStr Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title_full_unstemmed Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title_short Intraoperative margin assessment by wireless signals in thoracoscopic anterior (S3) segmentectomy using a radiofrequency identification marker
title_sort intraoperative margin assessment by wireless signals in thoracoscopic anterior (s3) segmentectomy using a radiofrequency identification marker
topic How to Do It
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9016051/
https://www.ncbi.nlm.nih.gov/pubmed/35064473
http://dx.doi.org/10.1007/s11748-021-01762-7
work_keys_str_mv AT yutakayojiro intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker
AT ohsumiakihiro intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker
AT nakajimadaisuke intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker
AT hamajimasatsugu intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker
AT menjutoshi intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker
AT datehiroshi intraoperativemarginassessmentbywirelesssignalsinthoracoscopicanteriors3segmentectomyusingaradiofrequencyidentificationmarker