Cargando…

Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty

BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clin...

Descripción completa

Detalles Bibliográficos
Autores principales: PIETILÄINEN, Sakari, LINNOVAARA, Axel, VENÄLÄINEN, Mikko S, MÄNTYMÄKI, Heikki, LAAKSONEN, Inari, LANKINEN, Petteri, MÄKELÄ, Keijo T
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017114/
https://www.ncbi.nlm.nih.gov/pubmed/35438184
http://dx.doi.org/10.2340/17453674.2022.2510
_version_ 1784688711454162944
author PIETILÄINEN, Sakari
LINNOVAARA, Axel
VENÄLÄINEN, Mikko S
MÄNTYMÄKI, Heikki
LAAKSONEN, Inari
LANKINEN, Petteri
MÄKELÄ, Keijo T
author_facet PIETILÄINEN, Sakari
LINNOVAARA, Axel
VENÄLÄINEN, Mikko S
MÄNTYMÄKI, Heikki
LAAKSONEN, Inari
LANKINEN, Petteri
MÄKELÄ, Keijo T
author_sort PIETILÄINEN, Sakari
collection PubMed
description BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS: Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION: WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.
format Online
Article
Text
id pubmed-9017114
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation
record_format MEDLINE/PubMed
spelling pubmed-90171142022-04-20 Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty PIETILÄINEN, Sakari LINNOVAARA, Axel VENÄLÄINEN, Mikko S MÄNTYMÄKI, Heikki LAAKSONEN, Inari LANKINEN, Petteri MÄKELÄ, Keijo T Acta Orthop Article BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS: Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION: WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients. Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022-04-19 /pmc/articles/PMC9017114/ /pubmed/35438184 http://dx.doi.org/10.2340/17453674.2022.2510 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work.
spellingShingle Article
PIETILÄINEN, Sakari
LINNOVAARA, Axel
VENÄLÄINEN, Mikko S
MÄNTYMÄKI, Heikki
LAAKSONEN, Inari
LANKINEN, Petteri
MÄKELÄ, Keijo T
Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title_full Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title_fullStr Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title_full_unstemmed Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title_short Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
title_sort median 10-year whole blood metal ion levels and clinical outcome of recap-m2a-magnum metal-on-metal total hip arthroplasty
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017114/
https://www.ncbi.nlm.nih.gov/pubmed/35438184
http://dx.doi.org/10.2340/17453674.2022.2510
work_keys_str_mv AT pietilainensakari median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT linnovaaraaxel median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT venalainenmikkos median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT mantymakiheikki median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT laaksoneninari median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT lankinenpetteri median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty
AT makelakeijot median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty