Cargando…
Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty
BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017114/ https://www.ncbi.nlm.nih.gov/pubmed/35438184 http://dx.doi.org/10.2340/17453674.2022.2510 |
_version_ | 1784688711454162944 |
---|---|
author | PIETILÄINEN, Sakari LINNOVAARA, Axel VENÄLÄINEN, Mikko S MÄNTYMÄKI, Heikki LAAKSONEN, Inari LANKINEN, Petteri MÄKELÄ, Keijo T |
author_facet | PIETILÄINEN, Sakari LINNOVAARA, Axel VENÄLÄINEN, Mikko S MÄNTYMÄKI, Heikki LAAKSONEN, Inari LANKINEN, Petteri MÄKELÄ, Keijo T |
author_sort | PIETILÄINEN, Sakari |
collection | PubMed |
description | BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS: Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION: WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients. |
format | Online Article Text |
id | pubmed-9017114 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation |
record_format | MEDLINE/PubMed |
spelling | pubmed-90171142022-04-20 Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty PIETILÄINEN, Sakari LINNOVAARA, Axel VENÄLÄINEN, Mikko S MÄNTYMÄKI, Heikki LAAKSONEN, Inari LANKINEN, Petteri MÄKELÄ, Keijo T Acta Orthop Article BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS: Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION: WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients. Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022-04-19 /pmc/articles/PMC9017114/ /pubmed/35438184 http://dx.doi.org/10.2340/17453674.2022.2510 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work. |
spellingShingle | Article PIETILÄINEN, Sakari LINNOVAARA, Axel VENÄLÄINEN, Mikko S MÄNTYMÄKI, Heikki LAAKSONEN, Inari LANKINEN, Petteri MÄKELÄ, Keijo T Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title_full | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title_fullStr | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title_full_unstemmed | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title_short | Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty |
title_sort | median 10-year whole blood metal ion levels and clinical outcome of recap-m2a-magnum metal-on-metal total hip arthroplasty |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017114/ https://www.ncbi.nlm.nih.gov/pubmed/35438184 http://dx.doi.org/10.2340/17453674.2022.2510 |
work_keys_str_mv | AT pietilainensakari median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT linnovaaraaxel median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT venalainenmikkos median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT mantymakiheikki median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT laaksoneninari median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT lankinenpetteri median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty AT makelakeijot median10yearwholebloodmetalionlevelsandclinicaloutcomeofrecapm2amagnummetalonmetaltotalhiparthroplasty |