Cargando…

Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia

OBJECTIVE: To explore the value of combining optical coherence tomography (OCT) with fundus photography in screening retinopathy in patients with high myopia. METHODS: By means of retrospective study, 40 high myopia patients with retinopathy treated in our hospital from January 2020 to January 2021...

Descripción completa

Detalles Bibliográficos
Autores principales: Hao, Yingjuan, Liu, Shiyang, Yu, Zhimin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017439/
https://www.ncbi.nlm.nih.gov/pubmed/35449843
http://dx.doi.org/10.1155/2022/6556867
_version_ 1784688762533445632
author Hao, Yingjuan
Liu, Shiyang
Yu, Zhimin
author_facet Hao, Yingjuan
Liu, Shiyang
Yu, Zhimin
author_sort Hao, Yingjuan
collection PubMed
description OBJECTIVE: To explore the value of combining optical coherence tomography (OCT) with fundus photography in screening retinopathy in patients with high myopia. METHODS: By means of retrospective study, 40 high myopia patients with retinopathy treated in our hospital from January 2020 to January 2021 were selected as the study group, and 40 healthy individuals in the same period were included in the control group. All patients received traditional ophthalmic examination, and accepted fundus fluorescence imaging, OCT, and fundus photography examination step by step by the same operator. After that, three physicians read the slides by the double blind method, and took the results of fundus fluorescence imaging as the gold standard to analyze the diagnostic efficacy of OCT, fundus photography and their combination. RESULTS: The clinical data and examination results showed that no statistical differences in general data including patients' mean age, gender ratio, and educational degree between the study group and the control group were observed (P > 0.05), and the nerve thickness above/below the optic disk and temporal/nasal nerve thickness of the optic disk of the study group were significantly different from those of the control group (P < 0.001); the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy rate of diagnosis of combining OCT with fundus photography were respectively 95.0%, 97.5%, 97.4%, 95.1%, and 96.3%, which were significantly higher than OCT or fundus photography alone (P < 0.05); and for combined examination, AUC (95%CI) = 0.963 (0.000–1.000). CONCLUSION: Combining OCT with fundus photography can effectively identify high myopia patients with retinopathy, which is conducive to improving clinical positive ratio and providing objective basis for treatment.
format Online
Article
Text
id pubmed-9017439
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-90174392022-04-20 Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia Hao, Yingjuan Liu, Shiyang Yu, Zhimin J Healthc Eng Research Article OBJECTIVE: To explore the value of combining optical coherence tomography (OCT) with fundus photography in screening retinopathy in patients with high myopia. METHODS: By means of retrospective study, 40 high myopia patients with retinopathy treated in our hospital from January 2020 to January 2021 were selected as the study group, and 40 healthy individuals in the same period were included in the control group. All patients received traditional ophthalmic examination, and accepted fundus fluorescence imaging, OCT, and fundus photography examination step by step by the same operator. After that, three physicians read the slides by the double blind method, and took the results of fundus fluorescence imaging as the gold standard to analyze the diagnostic efficacy of OCT, fundus photography and their combination. RESULTS: The clinical data and examination results showed that no statistical differences in general data including patients' mean age, gender ratio, and educational degree between the study group and the control group were observed (P > 0.05), and the nerve thickness above/below the optic disk and temporal/nasal nerve thickness of the optic disk of the study group were significantly different from those of the control group (P < 0.001); the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy rate of diagnosis of combining OCT with fundus photography were respectively 95.0%, 97.5%, 97.4%, 95.1%, and 96.3%, which were significantly higher than OCT or fundus photography alone (P < 0.05); and for combined examination, AUC (95%CI) = 0.963 (0.000–1.000). CONCLUSION: Combining OCT with fundus photography can effectively identify high myopia patients with retinopathy, which is conducive to improving clinical positive ratio and providing objective basis for treatment. Hindawi 2022-04-11 /pmc/articles/PMC9017439/ /pubmed/35449843 http://dx.doi.org/10.1155/2022/6556867 Text en Copyright © 2022 Yingjuan Hao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hao, Yingjuan
Liu, Shiyang
Yu, Zhimin
Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title_full Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title_fullStr Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title_full_unstemmed Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title_short Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
title_sort value of combining optical coherence tomography with fundus photography in screening retinopathy in patients with high myopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017439/
https://www.ncbi.nlm.nih.gov/pubmed/35449843
http://dx.doi.org/10.1155/2022/6556867
work_keys_str_mv AT haoyingjuan valueofcombiningopticalcoherencetomographywithfundusphotographyinscreeningretinopathyinpatientswithhighmyopia
AT liushiyang valueofcombiningopticalcoherencetomographywithfundusphotographyinscreeningretinopathyinpatientswithhighmyopia
AT yuzhimin valueofcombiningopticalcoherencetomographywithfundusphotographyinscreeningretinopathyinpatientswithhighmyopia