Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report

Wide-awake local anaesthesia, no tourniquet (WALANT) continues to gain popularity and has been adapted for various fracture fixations proximal to the hand. A case of olecranon tension band wiring with concomitant extensor tendon repair is presented. The procedure was done with the patient awake in a...

Descripción completa

Detalles Bibliográficos
Autor principal: Magtoto, IJ
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017904/
https://www.ncbi.nlm.nih.gov/pubmed/35519520
http://dx.doi.org/10.5704/MOJ.2203.023
_version_ 1784688885046968320
author Magtoto, IJ
author_facet Magtoto, IJ
author_sort Magtoto, IJ
collection PubMed
description Wide-awake local anaesthesia, no tourniquet (WALANT) continues to gain popularity and has been adapted for various fracture fixations proximal to the hand. A case of olecranon tension band wiring with concomitant extensor tendon repair is presented. The procedure was done with the patient awake in a lateral decubitus position 30min after the injection of WALANT solution at the intended surgical sites. Pain and discomfort were felt by the patient towards the end of the procedure mainly on his volar forearm where the bolster was placed. Olecranon fixation under WALANT is a viable alternative for patients who prefer to be awake or those with contraindications to general or regional anaesthesia. Alternative patient positioning may be considered, and perioperative pain control should not be overlooked.
format Online
Article
Text
id pubmed-9017904
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-90179042022-05-04 Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report Magtoto, IJ Malays Orthop J Case Reports Wide-awake local anaesthesia, no tourniquet (WALANT) continues to gain popularity and has been adapted for various fracture fixations proximal to the hand. A case of olecranon tension band wiring with concomitant extensor tendon repair is presented. The procedure was done with the patient awake in a lateral decubitus position 30min after the injection of WALANT solution at the intended surgical sites. Pain and discomfort were felt by the patient towards the end of the procedure mainly on his volar forearm where the bolster was placed. Olecranon fixation under WALANT is a viable alternative for patients who prefer to be awake or those with contraindications to general or regional anaesthesia. Alternative patient positioning may be considered, and perioperative pain control should not be overlooked. Malaysian Orthopaedic Association 2022-03 /pmc/articles/PMC9017904/ /pubmed/35519520 http://dx.doi.org/10.5704/MOJ.2203.023 Text en © 2022 Malaysian Orthopaedic Association MOA. All Rights Reserved https://creativecommons.org/licenses/by/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Case Reports
Magtoto, IJ
Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title_full Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title_fullStr Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title_full_unstemmed Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title_short Wide-Awake Olecranon Tension Band Wiring with Ipsilateral Zone 6 Extensor Tendon Repair: A Case Report
title_sort wide-awake olecranon tension band wiring with ipsilateral zone 6 extensor tendon repair: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9017904/
https://www.ncbi.nlm.nih.gov/pubmed/35519520
http://dx.doi.org/10.5704/MOJ.2203.023
work_keys_str_mv AT magtotoij wideawakeolecranontensionbandwiringwithipsilateralzone6extensortendonrepairacasereport