Cargando…

Clock drawing test: comparison between the Pfizer and the Shulman systems

Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and...

Descripción completa

Detalles Bibliográficos
Autores principales: Graeff, Daniela Bertol, Lui, Jéssica Maldaner, Zucco, Nathália Dal Prá, Alves, Ana Luisa Sant’Anna, Forcelini, Cassiano Mateus, Dalmolin, Bernadete Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação de Neurologia Cognitiva e do Comportamento 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9018089/
https://www.ncbi.nlm.nih.gov/pubmed/35509798
http://dx.doi.org/10.1590/1980-57642021dn15-040009
_version_ 1784688933836161024
author Graeff, Daniela Bertol
Lui, Jéssica Maldaner
Zucco, Nathália Dal Prá
Alves, Ana Luisa Sant’Anna
Forcelini, Cassiano Mateus
Dalmolin, Bernadete Maria
author_facet Graeff, Daniela Bertol
Lui, Jéssica Maldaner
Zucco, Nathália Dal Prá
Alves, Ana Luisa Sant’Anna
Forcelini, Cassiano Mateus
Dalmolin, Bernadete Maria
author_sort Graeff, Daniela Bertol
collection PubMed
description Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and comprised 404 subjects. Two raters underwent previous training and scored the subjects’ CDT according to both the Pfizer and Shulman systems. The inter-observer and intra-observer concordance within each method was analyzed with the Spearman’s rank correlation coefficient, as well as the concordance of the scores between the two methods. Age and scholarity were also correlated with the scores. RESULTS: Most of the participants were women (93.8%) and Caucasian (84.6%), with a mean age of 66.9 (±7.8) years and a scholarity of 10.9 years (±5.6). There was significant inter-observer (Pfizer: r=0.739, p£0.001; Shulman: r=0.727, p£0.001) and intra-observer correlation (Pfizer: rater 1, r=0.628, p≤0.001; rater 2, r=0.821, p≤0.001; Shulman: rater 1, r=0.843, p≤0.001; rater 2: r=0.819; p≤0.001). Intra-observer correlation was also observed comparing Pfizer and Shulman methods (rater 1: r=0.744; p≤0.001; rater 2: r=0.702; p≤0.001). There was weak correlation of the scores with scholarity (Pfizer: r=0.283, p£0.001; Shulman: r=0.244, p£0.001) and age (Pfizer: r=-0.174, p£0.001; Shulman: r=-0.170, p£0.001). More participants were classified with decreased cognition through the Pfizer system (rater 1: 44.3 vs. 26.5%; rater 2: 42.1 vs. 16.3%; p≤0.001). CONCLUSIONS: For this population, our results suggest that the Pfizer system of scoring CDT is more suitable for screening cognitive decline.
format Online
Article
Text
id pubmed-9018089
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Associação de Neurologia Cognitiva e do Comportamento
record_format MEDLINE/PubMed
spelling pubmed-90180892022-05-03 Clock drawing test: comparison between the Pfizer and the Shulman systems Graeff, Daniela Bertol Lui, Jéssica Maldaner Zucco, Nathália Dal Prá Alves, Ana Luisa Sant’Anna Forcelini, Cassiano Mateus Dalmolin, Bernadete Maria Dement Neuropsychol Original Article Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and comprised 404 subjects. Two raters underwent previous training and scored the subjects’ CDT according to both the Pfizer and Shulman systems. The inter-observer and intra-observer concordance within each method was analyzed with the Spearman’s rank correlation coefficient, as well as the concordance of the scores between the two methods. Age and scholarity were also correlated with the scores. RESULTS: Most of the participants were women (93.8%) and Caucasian (84.6%), with a mean age of 66.9 (±7.8) years and a scholarity of 10.9 years (±5.6). There was significant inter-observer (Pfizer: r=0.739, p£0.001; Shulman: r=0.727, p£0.001) and intra-observer correlation (Pfizer: rater 1, r=0.628, p≤0.001; rater 2, r=0.821, p≤0.001; Shulman: rater 1, r=0.843, p≤0.001; rater 2: r=0.819; p≤0.001). Intra-observer correlation was also observed comparing Pfizer and Shulman methods (rater 1: r=0.744; p≤0.001; rater 2: r=0.702; p≤0.001). There was weak correlation of the scores with scholarity (Pfizer: r=0.283, p£0.001; Shulman: r=0.244, p£0.001) and age (Pfizer: r=-0.174, p£0.001; Shulman: r=-0.170, p£0.001). More participants were classified with decreased cognition through the Pfizer system (rater 1: 44.3 vs. 26.5%; rater 2: 42.1 vs. 16.3%; p≤0.001). CONCLUSIONS: For this population, our results suggest that the Pfizer system of scoring CDT is more suitable for screening cognitive decline. Associação de Neurologia Cognitiva e do Comportamento 2021 /pmc/articles/PMC9018089/ /pubmed/35509798 http://dx.doi.org/10.1590/1980-57642021dn15-040009 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
Graeff, Daniela Bertol
Lui, Jéssica Maldaner
Zucco, Nathália Dal Prá
Alves, Ana Luisa Sant’Anna
Forcelini, Cassiano Mateus
Dalmolin, Bernadete Maria
Clock drawing test: comparison between the Pfizer and the Shulman systems
title Clock drawing test: comparison between the Pfizer and the Shulman systems
title_full Clock drawing test: comparison between the Pfizer and the Shulman systems
title_fullStr Clock drawing test: comparison between the Pfizer and the Shulman systems
title_full_unstemmed Clock drawing test: comparison between the Pfizer and the Shulman systems
title_short Clock drawing test: comparison between the Pfizer and the Shulman systems
title_sort clock drawing test: comparison between the pfizer and the shulman systems
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9018089/
https://www.ncbi.nlm.nih.gov/pubmed/35509798
http://dx.doi.org/10.1590/1980-57642021dn15-040009
work_keys_str_mv AT graeffdanielabertol clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems
AT luijessicamaldaner clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems
AT zucconathaliadalpra clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems
AT alvesanaluisasantanna clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems
AT forcelinicassianomateus clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems
AT dalmolinbernadetemaria clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems