Cargando…
Clock drawing test: comparison between the Pfizer and the Shulman systems
Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Associação de Neurologia Cognitiva e do Comportamento
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9018089/ https://www.ncbi.nlm.nih.gov/pubmed/35509798 http://dx.doi.org/10.1590/1980-57642021dn15-040009 |
_version_ | 1784688933836161024 |
---|---|
author | Graeff, Daniela Bertol Lui, Jéssica Maldaner Zucco, Nathália Dal Prá Alves, Ana Luisa Sant’Anna Forcelini, Cassiano Mateus Dalmolin, Bernadete Maria |
author_facet | Graeff, Daniela Bertol Lui, Jéssica Maldaner Zucco, Nathália Dal Prá Alves, Ana Luisa Sant’Anna Forcelini, Cassiano Mateus Dalmolin, Bernadete Maria |
author_sort | Graeff, Daniela Bertol |
collection | PubMed |
description | Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and comprised 404 subjects. Two raters underwent previous training and scored the subjects’ CDT according to both the Pfizer and Shulman systems. The inter-observer and intra-observer concordance within each method was analyzed with the Spearman’s rank correlation coefficient, as well as the concordance of the scores between the two methods. Age and scholarity were also correlated with the scores. RESULTS: Most of the participants were women (93.8%) and Caucasian (84.6%), with a mean age of 66.9 (±7.8) years and a scholarity of 10.9 years (±5.6). There was significant inter-observer (Pfizer: r=0.739, p£0.001; Shulman: r=0.727, p£0.001) and intra-observer correlation (Pfizer: rater 1, r=0.628, p≤0.001; rater 2, r=0.821, p≤0.001; Shulman: rater 1, r=0.843, p≤0.001; rater 2: r=0.819; p≤0.001). Intra-observer correlation was also observed comparing Pfizer and Shulman methods (rater 1: r=0.744; p≤0.001; rater 2: r=0.702; p≤0.001). There was weak correlation of the scores with scholarity (Pfizer: r=0.283, p£0.001; Shulman: r=0.244, p£0.001) and age (Pfizer: r=-0.174, p£0.001; Shulman: r=-0.170, p£0.001). More participants were classified with decreased cognition through the Pfizer system (rater 1: 44.3 vs. 26.5%; rater 2: 42.1 vs. 16.3%; p≤0.001). CONCLUSIONS: For this population, our results suggest that the Pfizer system of scoring CDT is more suitable for screening cognitive decline. |
format | Online Article Text |
id | pubmed-9018089 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Associação de Neurologia Cognitiva e do Comportamento |
record_format | MEDLINE/PubMed |
spelling | pubmed-90180892022-05-03 Clock drawing test: comparison between the Pfizer and the Shulman systems Graeff, Daniela Bertol Lui, Jéssica Maldaner Zucco, Nathália Dal Prá Alves, Ana Luisa Sant’Anna Forcelini, Cassiano Mateus Dalmolin, Bernadete Maria Dement Neuropsychol Original Article Cognitive decline can be screened by the clock drawing test (CDT), which has several versions. OBJECTIVE: This survey aimed to analyze the correlation between two simple methods for scoring the CDT. METHODS: This cross-sectional study was nested in the Elo-Creati cohort from Passo Fundo, Brazil and comprised 404 subjects. Two raters underwent previous training and scored the subjects’ CDT according to both the Pfizer and Shulman systems. The inter-observer and intra-observer concordance within each method was analyzed with the Spearman’s rank correlation coefficient, as well as the concordance of the scores between the two methods. Age and scholarity were also correlated with the scores. RESULTS: Most of the participants were women (93.8%) and Caucasian (84.6%), with a mean age of 66.9 (±7.8) years and a scholarity of 10.9 years (±5.6). There was significant inter-observer (Pfizer: r=0.739, p£0.001; Shulman: r=0.727, p£0.001) and intra-observer correlation (Pfizer: rater 1, r=0.628, p≤0.001; rater 2, r=0.821, p≤0.001; Shulman: rater 1, r=0.843, p≤0.001; rater 2: r=0.819; p≤0.001). Intra-observer correlation was also observed comparing Pfizer and Shulman methods (rater 1: r=0.744; p≤0.001; rater 2: r=0.702; p≤0.001). There was weak correlation of the scores with scholarity (Pfizer: r=0.283, p£0.001; Shulman: r=0.244, p£0.001) and age (Pfizer: r=-0.174, p£0.001; Shulman: r=-0.170, p£0.001). More participants were classified with decreased cognition through the Pfizer system (rater 1: 44.3 vs. 26.5%; rater 2: 42.1 vs. 16.3%; p≤0.001). CONCLUSIONS: For this population, our results suggest that the Pfizer system of scoring CDT is more suitable for screening cognitive decline. Associação de Neurologia Cognitiva e do Comportamento 2021 /pmc/articles/PMC9018089/ /pubmed/35509798 http://dx.doi.org/10.1590/1980-57642021dn15-040009 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | Original Article Graeff, Daniela Bertol Lui, Jéssica Maldaner Zucco, Nathália Dal Prá Alves, Ana Luisa Sant’Anna Forcelini, Cassiano Mateus Dalmolin, Bernadete Maria Clock drawing test: comparison between the Pfizer and the Shulman systems |
title | Clock drawing test: comparison between the Pfizer and the Shulman systems |
title_full | Clock drawing test: comparison between the Pfizer and the Shulman systems |
title_fullStr | Clock drawing test: comparison between the Pfizer and the Shulman systems |
title_full_unstemmed | Clock drawing test: comparison between the Pfizer and the Shulman systems |
title_short | Clock drawing test: comparison between the Pfizer and the Shulman systems |
title_sort | clock drawing test: comparison between the pfizer and the shulman systems |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9018089/ https://www.ncbi.nlm.nih.gov/pubmed/35509798 http://dx.doi.org/10.1590/1980-57642021dn15-040009 |
work_keys_str_mv | AT graeffdanielabertol clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems AT luijessicamaldaner clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems AT zucconathaliadalpra clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems AT alvesanaluisasantanna clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems AT forcelinicassianomateus clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems AT dalmolinbernadetemaria clockdrawingtestcomparisonbetweenthepfizerandtheshulmansystems |