Cargando…

A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin

Fast, convenient, and highly sensitive detection of antibiotic is essential to avoid its overuse and the possible harm. Owing to enrichment effect and antifouling ability of ultrasmall nanochannels, the vertically ordered mesoporous silica nanochannel film (VMSF) has great potential in the developme...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Xinjie, Luo, Xuan, Xu, Shuai, Xi, Fengna, Zhao, Tingting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9019221/
https://www.ncbi.nlm.nih.gov/pubmed/35464210
http://dx.doi.org/10.3389/fchem.2022.872582
_version_ 1784689209196412928
author Wei, Xinjie
Luo, Xuan
Xu, Shuai
Xi, Fengna
Zhao, Tingting
author_facet Wei, Xinjie
Luo, Xuan
Xu, Shuai
Xi, Fengna
Zhao, Tingting
author_sort Wei, Xinjie
collection PubMed
description Fast, convenient, and highly sensitive detection of antibiotic is essential to avoid its overuse and the possible harm. Owing to enrichment effect and antifouling ability of ultrasmall nanochannels, the vertically ordered mesoporous silica nanochannel film (VMSF) has great potential in the development of the facile electrochemiluminescence (ECL) sensor for direct and sensitive analysis of antibiotics in complex samples. In this study, we demonstrated a flexible ECL sensor based on a cost-effective electrode covered with a VMSF for sensitive detection of clindamycin. Polyethylene terephthalate coated with indium tin oxide (PET-ITO) is applied as a flexible electrode to grow VMSF using the electrochemically assisted self-assembly (EASA) method. The negatively charged VMSF nanochannels exhibit significant enrichment toward the commonly used cationic ECL luminophores, tris(2,2-bipyridyl) dichlororuthenium (II) (Ru (bpy)(3) (2+)). Using the enhanced ECL of Ru (bpy)(3) (2+) by clindamycin, the developed VMSF/PET-ITO sensor can sensitively detect clindamycin. The responses were linear in the concentration range of 10 nM–25 μM and in the concentration range of 25–70 μM. Owing to the nanoscale thickness of the VMSF and the high coupling stability with the electrode substrate, the developed flexible VMSF/PET-ITO sensor exhibits high signal stability during the continuous bending process. Considering high antifouling characteristic of the VMSF, direct analysis of clindamycin in a real biological sample, human serum, is realized.
format Online
Article
Text
id pubmed-9019221
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90192212022-04-21 A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin Wei, Xinjie Luo, Xuan Xu, Shuai Xi, Fengna Zhao, Tingting Front Chem Chemistry Fast, convenient, and highly sensitive detection of antibiotic is essential to avoid its overuse and the possible harm. Owing to enrichment effect and antifouling ability of ultrasmall nanochannels, the vertically ordered mesoporous silica nanochannel film (VMSF) has great potential in the development of the facile electrochemiluminescence (ECL) sensor for direct and sensitive analysis of antibiotics in complex samples. In this study, we demonstrated a flexible ECL sensor based on a cost-effective electrode covered with a VMSF for sensitive detection of clindamycin. Polyethylene terephthalate coated with indium tin oxide (PET-ITO) is applied as a flexible electrode to grow VMSF using the electrochemically assisted self-assembly (EASA) method. The negatively charged VMSF nanochannels exhibit significant enrichment toward the commonly used cationic ECL luminophores, tris(2,2-bipyridyl) dichlororuthenium (II) (Ru (bpy)(3) (2+)). Using the enhanced ECL of Ru (bpy)(3) (2+) by clindamycin, the developed VMSF/PET-ITO sensor can sensitively detect clindamycin. The responses were linear in the concentration range of 10 nM–25 μM and in the concentration range of 25–70 μM. Owing to the nanoscale thickness of the VMSF and the high coupling stability with the electrode substrate, the developed flexible VMSF/PET-ITO sensor exhibits high signal stability during the continuous bending process. Considering high antifouling characteristic of the VMSF, direct analysis of clindamycin in a real biological sample, human serum, is realized. Frontiers Media S.A. 2022-04-06 /pmc/articles/PMC9019221/ /pubmed/35464210 http://dx.doi.org/10.3389/fchem.2022.872582 Text en Copyright © 2022 Wei, Luo, Xu, Xi and Zhao. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Wei, Xinjie
Luo, Xuan
Xu, Shuai
Xi, Fengna
Zhao, Tingting
A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title_full A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title_fullStr A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title_full_unstemmed A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title_short A Flexible Electrochemiluminescence Sensor Equipped With Vertically Ordered Mesoporous Silica Nanochannel Film for Sensitive Detection of Clindamycin
title_sort flexible electrochemiluminescence sensor equipped with vertically ordered mesoporous silica nanochannel film for sensitive detection of clindamycin
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9019221/
https://www.ncbi.nlm.nih.gov/pubmed/35464210
http://dx.doi.org/10.3389/fchem.2022.872582
work_keys_str_mv AT weixinjie aflexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT luoxuan aflexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT xushuai aflexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT xifengna aflexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT zhaotingting aflexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT weixinjie flexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT luoxuan flexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT xushuai flexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT xifengna flexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin
AT zhaotingting flexibleelectrochemiluminescencesensorequippedwithverticallyorderedmesoporoussilicananochannelfilmforsensitivedetectionofclindamycin