Cargando…

ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study

BACKGROUND: Cortical suspensory fixation (CSF) devices gain more and more popularity as a reliable alternative to interference screws for graft fixation in anterior cruciate ligament (ACL) reconstruction. Adjustable-loop fixation may be associated with increased anterior laxity and inferior clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Schützenberger, Sebastian, Keller, F., Grabner, S., Kontic, D., Schallmayer, D., Komjati, M., Fialka, C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020032/
https://www.ncbi.nlm.nih.gov/pubmed/35440030
http://dx.doi.org/10.1186/s13018-022-03128-y
_version_ 1784689438076436480
author Schützenberger, Sebastian
Keller, F.
Grabner, S.
Kontic, D.
Schallmayer, D.
Komjati, M.
Fialka, C.
author_facet Schützenberger, Sebastian
Keller, F.
Grabner, S.
Kontic, D.
Schallmayer, D.
Komjati, M.
Fialka, C.
author_sort Schützenberger, Sebastian
collection PubMed
description BACKGROUND: Cortical suspensory fixation (CSF) devices gain more and more popularity as a reliable alternative to interference screws for graft fixation in anterior cruciate ligament (ACL) reconstruction. Adjustable-loop fixation may be associated with increased anterior laxity and inferior clinical outcome. The purpose of the study was to compare anterior laxity and clinical outcome after minimally invasive all-inside ACL reconstruction using an adjustable-loop (AL) to a standard technique with a fixed-loop (FL) CSF device. METHODS: Patients who underwent primary single-bundle ACL reconstruction with a quadrupled hamstring autograft at a single institution between 2012 and 2016 were reviewed. In the AL group minimally invasive popliteal tendon harvesting was performed with an all-inside approach (femoral and tibial sockets). In the FL group a traditional anteromedial approach was used for tendon harvesting and a femoral socket and full tibial tunnel were drilled. An objective clinical assessment was performed with Telos x-rays and the International Knee Documentation Committee (IKDC) Objective Score. Patient-reported outcomes (PRO) included the IKDC Subjective Score, the Lysholm Knee Score, the Knee Injury and Osteoarthritis Score (KOOS) and the Tegner Activity Scale. RESULTS: A total of 67 patients were enrolled in this retrospective study with a mean follow-up of 4 (± 1.5) years. The groups were homogenous at baseline regarding age, gender, and the time to surgery. At follow-up, no statistically significant differences were found regarding anterior laxity (AL: 2.3 ± 3 mm vs. FL: 2.3 ± 2.6 mm, p = 0.981). PRO scores were comparable between the AL and FL groups (IKDC score, 84.8 vs. 88.8, p = 0.185; Lysholm 87.3 vs. 89.9, p = 0.380; KOOS 90.7 vs. 91.4, p = 0.720; Tegner 5.5 vs. 6.2, p = 0.085). The rate of saphenous nerve lesions was significantly lower in the AL group with popliteal harvesting of the tendon (8.3% vs. 35.5%, p = 0.014). CONCLUSION: The use of an adjustable-loop device on the femoral and tibial side led to similar stability and clinical results compared to a fixed-loop device.
format Online
Article
Text
id pubmed-9020032
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-90200322022-04-21 ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study Schützenberger, Sebastian Keller, F. Grabner, S. Kontic, D. Schallmayer, D. Komjati, M. Fialka, C. J Orthop Surg Res Research BACKGROUND: Cortical suspensory fixation (CSF) devices gain more and more popularity as a reliable alternative to interference screws for graft fixation in anterior cruciate ligament (ACL) reconstruction. Adjustable-loop fixation may be associated with increased anterior laxity and inferior clinical outcome. The purpose of the study was to compare anterior laxity and clinical outcome after minimally invasive all-inside ACL reconstruction using an adjustable-loop (AL) to a standard technique with a fixed-loop (FL) CSF device. METHODS: Patients who underwent primary single-bundle ACL reconstruction with a quadrupled hamstring autograft at a single institution between 2012 and 2016 were reviewed. In the AL group minimally invasive popliteal tendon harvesting was performed with an all-inside approach (femoral and tibial sockets). In the FL group a traditional anteromedial approach was used for tendon harvesting and a femoral socket and full tibial tunnel were drilled. An objective clinical assessment was performed with Telos x-rays and the International Knee Documentation Committee (IKDC) Objective Score. Patient-reported outcomes (PRO) included the IKDC Subjective Score, the Lysholm Knee Score, the Knee Injury and Osteoarthritis Score (KOOS) and the Tegner Activity Scale. RESULTS: A total of 67 patients were enrolled in this retrospective study with a mean follow-up of 4 (± 1.5) years. The groups were homogenous at baseline regarding age, gender, and the time to surgery. At follow-up, no statistically significant differences were found regarding anterior laxity (AL: 2.3 ± 3 mm vs. FL: 2.3 ± 2.6 mm, p = 0.981). PRO scores were comparable between the AL and FL groups (IKDC score, 84.8 vs. 88.8, p = 0.185; Lysholm 87.3 vs. 89.9, p = 0.380; KOOS 90.7 vs. 91.4, p = 0.720; Tegner 5.5 vs. 6.2, p = 0.085). The rate of saphenous nerve lesions was significantly lower in the AL group with popliteal harvesting of the tendon (8.3% vs. 35.5%, p = 0.014). CONCLUSION: The use of an adjustable-loop device on the femoral and tibial side led to similar stability and clinical results compared to a fixed-loop device. BioMed Central 2022-04-19 /pmc/articles/PMC9020032/ /pubmed/35440030 http://dx.doi.org/10.1186/s13018-022-03128-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Schützenberger, Sebastian
Keller, F.
Grabner, S.
Kontic, D.
Schallmayer, D.
Komjati, M.
Fialka, C.
ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title_full ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title_fullStr ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title_full_unstemmed ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title_short ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
title_sort acl reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020032/
https://www.ncbi.nlm.nih.gov/pubmed/35440030
http://dx.doi.org/10.1186/s13018-022-03128-y
work_keys_str_mv AT schutzenbergersebastian aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT kellerf aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT grabners aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT konticd aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT schallmayerd aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT komjatim aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy
AT fialkac aclreconstructionwithfemoralandtibialadjustableversusfixedloopsuspensoryfixationaretrospectivecohortstudy