Cargando…

Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy

This study aimed to evaluate the efficiency and safety of indocyanine green (ICG) fluorescence real-time imaging-guided technology in laparoscopic hepatectomy. A retrospective analysis of patients with primary liver cancer in the First Affiliated Hospital of USTC from January 2018 to October 2021, i...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Hao, Wang, Yumin, Xie, Zhiguo, Zhang, Luyuan, Ge, Yongsheng, Yu, Jihai, Zhang, Chuanhai, Jia, Weidong, Ma, Jinliang, Liu, Wenbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020263/
https://www.ncbi.nlm.nih.gov/pubmed/35463377
http://dx.doi.org/10.3389/fonc.2022.819960
_version_ 1784689500726755328
author Chen, Hao
Wang, Yumin
Xie, Zhiguo
Zhang, Luyuan
Ge, Yongsheng
Yu, Jihai
Zhang, Chuanhai
Jia, Weidong
Ma, Jinliang
Liu, Wenbin
author_facet Chen, Hao
Wang, Yumin
Xie, Zhiguo
Zhang, Luyuan
Ge, Yongsheng
Yu, Jihai
Zhang, Chuanhai
Jia, Weidong
Ma, Jinliang
Liu, Wenbin
author_sort Chen, Hao
collection PubMed
description This study aimed to evaluate the efficiency and safety of indocyanine green (ICG) fluorescence real-time imaging-guided technology in laparoscopic hepatectomy. A retrospective analysis of patients with primary liver cancer in the First Affiliated Hospital of USTC from January 2018 to October 2021, including 48 cases of fluorescence-guided laparoscopic hepatectomy (FGLH) and 60 cases of traditional laparoscopic hepatectomy (LH), was conducted. R0 resection rate, operation time, intraoperative blood loss, complications, hospital stay, and other intraoperative and postoperative indicators of the two groups were analyzed to determine the clinical feasibility and safety of ICG fluorescence real-time imaging-guided technology in laparoscopic hepatectomy. Related databases were searched for retrospective cohort studies and randomized controlled trials comparing FGLH with LH, studies were screened according to preset inclusion and exclusion criteria, literature quality was evaluated, and data were extracted. RevMan 5.3 software was used to conduct a meta-analysis on the extracted data. The results of our clinical data and meta-analysis showed that compared with LH, FGLH increased the R0 resection rate, shortened the operation time and postoperative hospital stay, and reduced blood loss and the occurrence of postoperative complications. Compared with LH, FGLH has a better application effect in laparoscopic hepatectomy, and it is worthy of promotion as it is safe and feasible.
format Online
Article
Text
id pubmed-9020263
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90202632022-04-21 Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy Chen, Hao Wang, Yumin Xie, Zhiguo Zhang, Luyuan Ge, Yongsheng Yu, Jihai Zhang, Chuanhai Jia, Weidong Ma, Jinliang Liu, Wenbin Front Oncol Oncology This study aimed to evaluate the efficiency and safety of indocyanine green (ICG) fluorescence real-time imaging-guided technology in laparoscopic hepatectomy. A retrospective analysis of patients with primary liver cancer in the First Affiliated Hospital of USTC from January 2018 to October 2021, including 48 cases of fluorescence-guided laparoscopic hepatectomy (FGLH) and 60 cases of traditional laparoscopic hepatectomy (LH), was conducted. R0 resection rate, operation time, intraoperative blood loss, complications, hospital stay, and other intraoperative and postoperative indicators of the two groups were analyzed to determine the clinical feasibility and safety of ICG fluorescence real-time imaging-guided technology in laparoscopic hepatectomy. Related databases were searched for retrospective cohort studies and randomized controlled trials comparing FGLH with LH, studies were screened according to preset inclusion and exclusion criteria, literature quality was evaluated, and data were extracted. RevMan 5.3 software was used to conduct a meta-analysis on the extracted data. The results of our clinical data and meta-analysis showed that compared with LH, FGLH increased the R0 resection rate, shortened the operation time and postoperative hospital stay, and reduced blood loss and the occurrence of postoperative complications. Compared with LH, FGLH has a better application effect in laparoscopic hepatectomy, and it is worthy of promotion as it is safe and feasible. Frontiers Media S.A. 2022-04-06 /pmc/articles/PMC9020263/ /pubmed/35463377 http://dx.doi.org/10.3389/fonc.2022.819960 Text en Copyright © 2022 Chen, Wang, Xie, Zhang, Ge, Yu, Zhang, Jia, Ma and Liu https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Chen, Hao
Wang, Yumin
Xie, Zhiguo
Zhang, Luyuan
Ge, Yongsheng
Yu, Jihai
Zhang, Chuanhai
Jia, Weidong
Ma, Jinliang
Liu, Wenbin
Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title_full Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title_fullStr Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title_full_unstemmed Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title_short Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy
title_sort application effect of icg fluorescence real-time imaging technology in laparoscopic hepatectomy
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020263/
https://www.ncbi.nlm.nih.gov/pubmed/35463377
http://dx.doi.org/10.3389/fonc.2022.819960
work_keys_str_mv AT chenhao applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT wangyumin applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT xiezhiguo applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT zhangluyuan applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT geyongsheng applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT yujihai applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT zhangchuanhai applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT jiaweidong applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT majinliang applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy
AT liuwenbin applicationeffectoficgfluorescencerealtimeimagingtechnologyinlaparoscopichepatectomy