Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets

PURPOSE: To compare the accuracy of intraoperative aberrometry (IA) for predicting postoperative refraction between eyes with emmetropia and myopia targets. PATIENTS AND METHODS: This retrospective analysis included patients with axial myopia (axial length ≥ 25.0 mm) who underwent uncomplicated phac...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakai, Daiki, Demoto, Sakiko, Iwai, Yukako, Hirami, Yasuhiko, Nakamura, Makoto, Kurimoto, Yasuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020572/
https://www.ncbi.nlm.nih.gov/pubmed/35465196
http://dx.doi.org/10.2147/OPTH.S363228
_version_ 1784689584351739904
author Sakai, Daiki
Demoto, Sakiko
Iwai, Yukako
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
author_facet Sakai, Daiki
Demoto, Sakiko
Iwai, Yukako
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
author_sort Sakai, Daiki
collection PubMed
description PURPOSE: To compare the accuracy of intraoperative aberrometry (IA) for predicting postoperative refraction between eyes with emmetropia and myopia targets. PATIENTS AND METHODS: This retrospective analysis included patients with axial myopia (axial length ≥ 25.0 mm) who underwent uncomplicated phacoemulsification cataract surgery with IA to achieve emmetropia (plano to −0.5 D) or intentional myopia (−2.5 D to −5.0 D). Preoperative ocular biometry was performed in all eyes using an IOLMaster. Refractive prediction errors in IA were compared between eyes with emmetropia and myopia targets. Refractive prediction errors in IA for both groups were also compared with those predicted by intraocular lens power calculation formulas including the SRK/T, Holladay 1, Hoffer Q, Holladay 2, Haigis, and Barrett Universal II formulas. RESULTS: Thirty-nine eyes of 39 patients with a target of emmetropia and 22 eyes of 22 patients with a target of intentional myopia were included in the final analysis. The mean numerical error was significantly different from zero (myopic trend) in myopia-targeted eyes (−0.37 ± 0.54 D, one-sample t-test, P = 0.004, 95% confidence interval: −0.61 to −0.14), while it was close to zero in emmetropia-targeted eyes. The mean absolute error was significantly smaller in emmetropia-targeted eyes (0.28 ± 0.27 D) than in myopia-targeted eyes (0.51 ± 0.41 D, P = 0.01). IA was revealed as the most accurate method for predicting postoperative refraction in eyes with emmetropia target, whereas Barrett Universal II formula was found to be the most accurate for eyes with myopia target. CONCLUSION: In patients with axial myopia, the performance of IA was altered when targeting intentional myopia compared with emmetropia. Myopic shift in the refractive outcome should be considered when IA is used to target myopia.
format Online
Article
Text
id pubmed-9020572
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-90205722022-04-21 Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets Sakai, Daiki Demoto, Sakiko Iwai, Yukako Hirami, Yasuhiko Nakamura, Makoto Kurimoto, Yasuo Clin Ophthalmol Original Research PURPOSE: To compare the accuracy of intraoperative aberrometry (IA) for predicting postoperative refraction between eyes with emmetropia and myopia targets. PATIENTS AND METHODS: This retrospective analysis included patients with axial myopia (axial length ≥ 25.0 mm) who underwent uncomplicated phacoemulsification cataract surgery with IA to achieve emmetropia (plano to −0.5 D) or intentional myopia (−2.5 D to −5.0 D). Preoperative ocular biometry was performed in all eyes using an IOLMaster. Refractive prediction errors in IA were compared between eyes with emmetropia and myopia targets. Refractive prediction errors in IA for both groups were also compared with those predicted by intraocular lens power calculation formulas including the SRK/T, Holladay 1, Hoffer Q, Holladay 2, Haigis, and Barrett Universal II formulas. RESULTS: Thirty-nine eyes of 39 patients with a target of emmetropia and 22 eyes of 22 patients with a target of intentional myopia were included in the final analysis. The mean numerical error was significantly different from zero (myopic trend) in myopia-targeted eyes (−0.37 ± 0.54 D, one-sample t-test, P = 0.004, 95% confidence interval: −0.61 to −0.14), while it was close to zero in emmetropia-targeted eyes. The mean absolute error was significantly smaller in emmetropia-targeted eyes (0.28 ± 0.27 D) than in myopia-targeted eyes (0.51 ± 0.41 D, P = 0.01). IA was revealed as the most accurate method for predicting postoperative refraction in eyes with emmetropia target, whereas Barrett Universal II formula was found to be the most accurate for eyes with myopia target. CONCLUSION: In patients with axial myopia, the performance of IA was altered when targeting intentional myopia compared with emmetropia. Myopic shift in the refractive outcome should be considered when IA is used to target myopia. Dove 2022-04-16 /pmc/articles/PMC9020572/ /pubmed/35465196 http://dx.doi.org/10.2147/OPTH.S363228 Text en © 2022 Sakai et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Sakai, Daiki
Demoto, Sakiko
Iwai, Yukako
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title_full Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title_fullStr Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title_full_unstemmed Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title_short Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets
title_sort comparison of the accuracy of intraoperative aberrometry in intraocular lens implantation between myopic eyes with emmetropia and myopia targets
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9020572/
https://www.ncbi.nlm.nih.gov/pubmed/35465196
http://dx.doi.org/10.2147/OPTH.S363228
work_keys_str_mv AT sakaidaiki comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets
AT demotosakiko comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets
AT iwaiyukako comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets
AT hiramiyasuhiko comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets
AT nakamuramakoto comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets
AT kurimotoyasuo comparisonoftheaccuracyofintraoperativeaberrometryinintraocularlensimplantationbetweenmyopiceyeswithemmetropiaandmyopiatargets