Cargando…
Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology
BACKGROUND: Anthracnose of Camellia oleifera is a very destructive disease that commonly occurs in the Camellia oleifera industry, which severely restricts the development of the Camellia oleifera industry. In the early stage of the Camellia oleifera suffering from anthracnose, only the diseased par...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022339/ https://www.ncbi.nlm.nih.gov/pubmed/35443667 http://dx.doi.org/10.1186/s13007-022-00883-1 |
_version_ | 1784690060838305792 |
---|---|
author | Bin, Li Qiu, Wang Chao-hui, Zhan Zhao-yang, Han Hai, Yin Jun, Liao Yan-de, Liu |
author_facet | Bin, Li Qiu, Wang Chao-hui, Zhan Zhao-yang, Han Hai, Yin Jun, Liao Yan-de, Liu |
author_sort | Bin, Li |
collection | PubMed |
description | BACKGROUND: Anthracnose of Camellia oleifera is a very destructive disease that commonly occurs in the Camellia oleifera industry, which severely restricts the development of the Camellia oleifera industry. In the early stage of the Camellia oleifera suffering from anthracnose, only the diseased parts of the tree need to be repaired in time. With the aggravation of the disease, the diseased branches need to be eradicated, and severely diseased plants should be cut down in time. At present, aiming at the problems of complex experiments and low accuracy in detecting the degree of anthracnose of Camellia oleifera, a method is proposed to detect the degree of anthracnose of Camellia oleifera leaves by using terahertz spectroscopy (THz) combined with laser-induced breakdown spectroscopy (LIBS), so as to realize the rapid, efficient, non-destructive and high-precision determination of the degree of anthracnose of Camellia oleifera. RESULTS: Mn, Ca, Ca II, Fe and other elements in the LIBS spectrum of healthy and infected Camellia oleifera leaves with different degrees of anthracnose are significantly different, and the Terahertz absorption spectra of healthy Camellia oleifera leaves, and Camellia oleifera leaves with different degrees of anthracnose there are also significant differences. Partial least squares discriminant analysis (PLS-DA), support vector machine (SVM), and linear discriminant analysis (LDA) are used to establish the fusion spectrum anthracnose classification model of Camellia oleifera. Among them, the Root mean square error of prediction (RMSEP) and the prediction determination coefficient R(2)p of THz-LIBS-CARS-PLS-DA of prediction set are 0.110 and 0.995 respectively, and the misjudgment rate is 1.03%; The accuracy of the modeling set of THz (CARS)-LIBS (CARS)-SVM is 100%, and the accuracy of prediction set is 100%, after preprocessing of the multivariate scattering correction (MSC), the accuracy of the THz-LIBS-MSC-CARS modeling set is 100%, and the accuracy of prediction set is 100%; The accuracy rate of THz-LIBS-MSC-CARS-LDA of modeling set is 98.98%, and the accuracy rate of the prediction set is 96.87%. CONCLUSION: The experimental results show that: the SVM model has higher qualitative analysis accuracy and is more stable than the PLS-DA and LDA models. The results showed that: the THz spectrum combined with the LIBS spectrum could be used to separate healthy Camellia oleifera leaves from various grades of anthracnose Camellia oleifera leaves non-destructively, quickly and accurately. |
format | Online Article Text |
id | pubmed-9022339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-90223392022-04-22 Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology Bin, Li Qiu, Wang Chao-hui, Zhan Zhao-yang, Han Hai, Yin Jun, Liao Yan-de, Liu Plant Methods Research BACKGROUND: Anthracnose of Camellia oleifera is a very destructive disease that commonly occurs in the Camellia oleifera industry, which severely restricts the development of the Camellia oleifera industry. In the early stage of the Camellia oleifera suffering from anthracnose, only the diseased parts of the tree need to be repaired in time. With the aggravation of the disease, the diseased branches need to be eradicated, and severely diseased plants should be cut down in time. At present, aiming at the problems of complex experiments and low accuracy in detecting the degree of anthracnose of Camellia oleifera, a method is proposed to detect the degree of anthracnose of Camellia oleifera leaves by using terahertz spectroscopy (THz) combined with laser-induced breakdown spectroscopy (LIBS), so as to realize the rapid, efficient, non-destructive and high-precision determination of the degree of anthracnose of Camellia oleifera. RESULTS: Mn, Ca, Ca II, Fe and other elements in the LIBS spectrum of healthy and infected Camellia oleifera leaves with different degrees of anthracnose are significantly different, and the Terahertz absorption spectra of healthy Camellia oleifera leaves, and Camellia oleifera leaves with different degrees of anthracnose there are also significant differences. Partial least squares discriminant analysis (PLS-DA), support vector machine (SVM), and linear discriminant analysis (LDA) are used to establish the fusion spectrum anthracnose classification model of Camellia oleifera. Among them, the Root mean square error of prediction (RMSEP) and the prediction determination coefficient R(2)p of THz-LIBS-CARS-PLS-DA of prediction set are 0.110 and 0.995 respectively, and the misjudgment rate is 1.03%; The accuracy of the modeling set of THz (CARS)-LIBS (CARS)-SVM is 100%, and the accuracy of prediction set is 100%, after preprocessing of the multivariate scattering correction (MSC), the accuracy of the THz-LIBS-MSC-CARS modeling set is 100%, and the accuracy of prediction set is 100%; The accuracy rate of THz-LIBS-MSC-CARS-LDA of modeling set is 98.98%, and the accuracy rate of the prediction set is 96.87%. CONCLUSION: The experimental results show that: the SVM model has higher qualitative analysis accuracy and is more stable than the PLS-DA and LDA models. The results showed that: the THz spectrum combined with the LIBS spectrum could be used to separate healthy Camellia oleifera leaves from various grades of anthracnose Camellia oleifera leaves non-destructively, quickly and accurately. BioMed Central 2022-04-20 /pmc/articles/PMC9022339/ /pubmed/35443667 http://dx.doi.org/10.1186/s13007-022-00883-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Bin, Li Qiu, Wang Chao-hui, Zhan Zhao-yang, Han Hai, Yin Jun, Liao Yan-de, Liu Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title | Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title_full | Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title_fullStr | Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title_full_unstemmed | Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title_short | Research on anthracnose grade of Camellia oleifera based on the combined LIBS and THz technology |
title_sort | research on anthracnose grade of camellia oleifera based on the combined libs and thz technology |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022339/ https://www.ncbi.nlm.nih.gov/pubmed/35443667 http://dx.doi.org/10.1186/s13007-022-00883-1 |
work_keys_str_mv | AT binli researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT qiuwang researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT chaohuizhan researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT zhaoyanghan researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT haiyin researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT junliao researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology AT yandeliu researchonanthracnosegradeofcamelliaoleiferabasedonthecombinedlibsandthztechnology |