Cargando…
Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever
This study aimed to compare strain around implants used as abutments for removable partial dentures with wrought wires and fixed partial dentures with ball attachments and fixed dentures with posterior cantilever. An edentulous mandibular model was constructed using epoxy resin with four parallel im...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022369/ https://www.ncbi.nlm.nih.gov/pubmed/35464659 http://dx.doi.org/10.4103/japtr.japtr_160_21 |
_version_ | 1784690067726401536 |
---|---|
author | Koodaryan, Roodabeh Yasamineh, Neda Hafezeqoran, Ali Moharrer, Sheida Monem Noorazar, Seyed Gholamreza |
author_facet | Koodaryan, Roodabeh Yasamineh, Neda Hafezeqoran, Ali Moharrer, Sheida Monem Noorazar, Seyed Gholamreza |
author_sort | Koodaryan, Roodabeh |
collection | PubMed |
description | This study aimed to compare strain around implants used as abutments for removable partial dentures with wrought wires and fixed partial dentures with ball attachments and fixed dentures with posterior cantilever. An edentulous mandibular model was constructed using epoxy resin with four parallel implants in the area between the two mental foramina. Four strain gauges were attached to the buccal, lingual, mesial, and distal aspects of each implant. One fixed prosthesis with cantilever and two removable partial dentures were considered as prosthetic treatments. A vertical 500-N force was applied with 10-N intervals. The maximum strain in the fixed prosthesis was higher than that of the partial removable denture; in the removable denture with a wrought wire arm, it was higher than that in the denture with a ball attachment (P < 0.001). The lowest rate of strain was recorded on the mesial aspect (P < 0.05). However, the highest rate of strain was recorded on the lingual and distal aspects of the removable denture with a wrought wire in the buccal aspect and the removable prosthesis with the ball attachment on the buccal and lingual aspects (P < 0.05). Finally, despite minor differences in the maximum strain rate in each implant position, the differences were not statistically significant (P > 0.05). Partial removable denture with a ball attachment decreased strain more than that by the removable portal denture with a wrought wire arm. The worst type of prosthesis in terms of the overall strain rate was the fixed prosthesis with cantilever. |
format | Online Article Text |
id | pubmed-9022369 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-90223692022-04-22 Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever Koodaryan, Roodabeh Yasamineh, Neda Hafezeqoran, Ali Moharrer, Sheida Monem Noorazar, Seyed Gholamreza J Adv Pharm Technol Res Original Article This study aimed to compare strain around implants used as abutments for removable partial dentures with wrought wires and fixed partial dentures with ball attachments and fixed dentures with posterior cantilever. An edentulous mandibular model was constructed using epoxy resin with four parallel implants in the area between the two mental foramina. Four strain gauges were attached to the buccal, lingual, mesial, and distal aspects of each implant. One fixed prosthesis with cantilever and two removable partial dentures were considered as prosthetic treatments. A vertical 500-N force was applied with 10-N intervals. The maximum strain in the fixed prosthesis was higher than that of the partial removable denture; in the removable denture with a wrought wire arm, it was higher than that in the denture with a ball attachment (P < 0.001). The lowest rate of strain was recorded on the mesial aspect (P < 0.05). However, the highest rate of strain was recorded on the lingual and distal aspects of the removable denture with a wrought wire in the buccal aspect and the removable prosthesis with the ball attachment on the buccal and lingual aspects (P < 0.05). Finally, despite minor differences in the maximum strain rate in each implant position, the differences were not statistically significant (P > 0.05). Partial removable denture with a ball attachment decreased strain more than that by the removable portal denture with a wrought wire arm. The worst type of prosthesis in terms of the overall strain rate was the fixed prosthesis with cantilever. Wolters Kluwer - Medknow 2022 2022-04-07 /pmc/articles/PMC9022369/ /pubmed/35464659 http://dx.doi.org/10.4103/japtr.japtr_160_21 Text en Copyright: © 2022 Journal of Advanced Pharmaceutical Technology & Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Koodaryan, Roodabeh Yasamineh, Neda Hafezeqoran, Ali Moharrer, Sheida Monem Noorazar, Seyed Gholamreza Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title | Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title_full | Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title_fullStr | Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title_full_unstemmed | Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title_short | Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
title_sort | determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022369/ https://www.ncbi.nlm.nih.gov/pubmed/35464659 http://dx.doi.org/10.4103/japtr.japtr_160_21 |
work_keys_str_mv | AT koodaryanroodabeh determinationofstrainarounddistalimplantsasabutmentsforpartialandfixedimplantsupportedprostheseswithposteriorcantilever AT yasaminehneda determinationofstrainarounddistalimplantsasabutmentsforpartialandfixedimplantsupportedprostheseswithposteriorcantilever AT hafezeqoranali determinationofstrainarounddistalimplantsasabutmentsforpartialandfixedimplantsupportedprostheseswithposteriorcantilever AT moharrersheidamonem determinationofstrainarounddistalimplantsasabutmentsforpartialandfixedimplantsupportedprostheseswithposteriorcantilever AT noorazarseyedgholamreza determinationofstrainarounddistalimplantsasabutmentsforpartialandfixedimplantsupportedprostheseswithposteriorcantilever |