Cargando…

3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction

OBJECTIVES: Historically, unstable injuries to the distal tibiofibular syndesmosis have been repaired with syndesmotic screws. However, newer repair techniques with inherently flexible implants, including suture-button constructs, may be less susceptible to malreduction and more reliably restore the...

Descripción completa

Detalles Bibliográficos
Autores principales: Turnbull, Travis L., Schon, Jason, Williams, Brady T., Venderley, Melanie, Dornan, Grant, Backus, Jonathon D., LaPrade, Robert F., Clanton, Thomas O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022949/
http://dx.doi.org/10.1177/2325967116S00145
_version_ 1784690222156480512
author Turnbull, Travis L.
Schon, Jason
Williams, Brady T.
Venderley, Melanie
Dornan, Grant
Backus, Jonathon D.
LaPrade, Robert F.
Clanton, Thomas O.
author_facet Turnbull, Travis L.
Schon, Jason
Williams, Brady T.
Venderley, Melanie
Dornan, Grant
Backus, Jonathon D.
LaPrade, Robert F.
Clanton, Thomas O.
author_sort Turnbull, Travis L.
collection PubMed
description OBJECTIVES: Historically, unstable injuries to the distal tibiofibular syndesmosis have been repaired with syndesmotic screws. However, newer repair techniques with inherently flexible implants, including suture-button constructs, may be less susceptible to malreduction and more reliably restore the native anatomy. The purpose of this study was to compare the anatomic accuracy of reduction between a syndesmotic screw and suture-button constructs for syndesmosis repair using a pre-injury and postoperative 3-D model assessment. We hypothesized significant differences would be observed among repair techniques and suture-button constructs would most accurately restore the pre-injury syndesmotic volume. METHODS: Twelve matched pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury. The disrupted syndesmosis of each specimen was subsequently reduced using one of three randomly assigned repair techniques: (1) tri-cortical syndesmosis screw (3.5 x 50 mm), (2) one suture-button construct and (3) two suture-button constructs. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were created to assess restoration of the native syndesmosis (Figure 1). Volumetric joint space measurements were made starting at the distal aspect of the tibiofibular articulation and extended proximally with four 1 cm sections measured separately. RESULTS: For each of the three fixation methods, the adjusted least squares means for total post-operative volumes of the syndesmosis were significantly decreased relative to the intact state. Total overall decreases in volume compared to the intact state for the one suture-button construct, two suture-button constructs, and syndesmotic screw were -561mm(3), -964mm(3), and -377mm(3), respectively. Fixation with one suture-button construct was not significantly different from screw or two suture-button fixations. However, the total decrease in volume was significantly greater with the two suture-button repair compared to screw fixation (p < .05). CONCLUSION: The most important finding of this study was that fixation with one suture-button construct was not significantly different from screw or two suture-button fixations. All repairs significantly reduced the volume of the syndesmosis postoperatively compared to the intact state. Fixation with two suture-buttons resulted in significantly greater decreased volume than screw fixation. The data from the present study suggests that syndesmotic over-compression at time zero, particularly when using multiple suture-button implants, may be another potential factor contributing to malreduction of syndesmosis injuries that deserves further investigation.
format Online
Article
Text
id pubmed-9022949
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-90229492022-04-22 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction Turnbull, Travis L. Schon, Jason Williams, Brady T. Venderley, Melanie Dornan, Grant Backus, Jonathon D. LaPrade, Robert F. Clanton, Thomas O. Orthop J Sports Med Article OBJECTIVES: Historically, unstable injuries to the distal tibiofibular syndesmosis have been repaired with syndesmotic screws. However, newer repair techniques with inherently flexible implants, including suture-button constructs, may be less susceptible to malreduction and more reliably restore the native anatomy. The purpose of this study was to compare the anatomic accuracy of reduction between a syndesmotic screw and suture-button constructs for syndesmosis repair using a pre-injury and postoperative 3-D model assessment. We hypothesized significant differences would be observed among repair techniques and suture-button constructs would most accurately restore the pre-injury syndesmotic volume. METHODS: Twelve matched pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury. The disrupted syndesmosis of each specimen was subsequently reduced using one of three randomly assigned repair techniques: (1) tri-cortical syndesmosis screw (3.5 x 50 mm), (2) one suture-button construct and (3) two suture-button constructs. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were created to assess restoration of the native syndesmosis (Figure 1). Volumetric joint space measurements were made starting at the distal aspect of the tibiofibular articulation and extended proximally with four 1 cm sections measured separately. RESULTS: For each of the three fixation methods, the adjusted least squares means for total post-operative volumes of the syndesmosis were significantly decreased relative to the intact state. Total overall decreases in volume compared to the intact state for the one suture-button construct, two suture-button constructs, and syndesmotic screw were -561mm(3), -964mm(3), and -377mm(3), respectively. Fixation with one suture-button construct was not significantly different from screw or two suture-button fixations. However, the total decrease in volume was significantly greater with the two suture-button repair compared to screw fixation (p < .05). CONCLUSION: The most important finding of this study was that fixation with one suture-button construct was not significantly different from screw or two suture-button fixations. All repairs significantly reduced the volume of the syndesmosis postoperatively compared to the intact state. Fixation with two suture-buttons resulted in significantly greater decreased volume than screw fixation. The data from the present study suggests that syndesmotic over-compression at time zero, particularly when using multiple suture-button implants, may be another potential factor contributing to malreduction of syndesmosis injuries that deserves further investigation. SAGE Publications 2016-07-18 /pmc/articles/PMC9022949/ http://dx.doi.org/10.1177/2325967116S00145 Text en © The Author(s) 2016 https://creativecommons.org/licenses/by-nc-nd/3.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/ (https://creativecommons.org/licenses/by-nc-nd/3.0/) ), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Turnbull, Travis L.
Schon, Jason
Williams, Brady T.
Venderley, Melanie
Dornan, Grant
Backus, Jonathon D.
LaPrade, Robert F.
Clanton, Thomas O.
3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title_full 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title_fullStr 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title_full_unstemmed 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title_short 3-D Computed Tomography (CT) Comparison Of The Pre-injury And Post-repair Syndesmosis To Assess Anatomic Reduction
title_sort 3-d computed tomography (ct) comparison of the pre-injury and post-repair syndesmosis to assess anatomic reduction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9022949/
http://dx.doi.org/10.1177/2325967116S00145
work_keys_str_mv AT turnbulltravisl 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT schonjason 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT williamsbradyt 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT venderleymelanie 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT dornangrant 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT backusjonathond 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT lapraderobertf 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction
AT clantonthomaso 3dcomputedtomographyctcomparisonofthepreinjuryandpostrepairsyndesmosistoassessanatomicreduction