Cargando…

Subcutaneous Implantable Cardioverter-defibrillator Explantation—A Single Tertiary Center Experience

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an appealing alternative to transvenous ICD systems. However, data on indications for S-ICD explantations are sparse. The objective of this study was to assess the incidence and indications for S-ICD explantation at a large tertiary...

Descripción completa

Detalles Bibliográficos
Autores principales: Pothineni, Naga Venkata K., Cherian, Tharian, Patel, Neel, Smietana, Jeffrey, Frankel, David S., Deo, Rajat, Epstein, Andrew E., Marchlinski, Francis E., Schaller, Robert D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9023024/
https://www.ncbi.nlm.nih.gov/pubmed/35474857
http://dx.doi.org/10.19102/icrm.2022.130407
Descripción
Sumario:The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an appealing alternative to transvenous ICD systems. However, data on indications for S-ICD explantations are sparse. The objective of this study was to assess the incidence and indications for S-ICD explantation at a large tertiary referral center. We conducted a retrospective study of all S-ICD explantations performed from 2014–2020. Data on demographics, comorbidities, implantation characteristics, and indications for explantation were collected. A total of 64 patients underwent S-ICD explantation during the study period. During that time, there were 410 S-ICD implantations at our institution, of which 53 (12.9%) were explanted with a mean duration from implant to explant of 19.7 ± 20.1 months. The mean age of the patients at explantation was 44.8 ± 15.3 years, and 42% (n = 27) were women. The indication for S-ICD implantation was primary prevention in 58% and secondary prevention in 42% of patients, respectively. The most common reason for explantation was infection (32.8%), followed by abnormal sensing (25%) and the need for pacing (18.8%). Those who underwent S-ICD explantation for pacing indications were significantly older (55.7 ± 13.6 vs. 42.3 ± 14.6 years, P = 0.005) with a wider QRS duration (111 ± 19 vs. 98 ± 19 ms, P = 0.03) at device implantation compared to patients who underwent explantation for other indications. The incidence of S-ICD explantation in a large tertiary practice was 12.9%. While infection was the indication for one-third of the explantations, a significant number of explantations were due to sensing abnormalities and the need for pacing. These data may have implications for patient selection for S-ICD implantation.