Cargando…

The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically

The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechan...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jing-Chi, Xie, Tian-Hang, Zhang, Zhuang, Song, Zhe-Tao, Song, Yue-Ming, Zeng, Jian-Cheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9023805/
https://www.ncbi.nlm.nih.gov/pubmed/35464717
http://dx.doi.org/10.3389/fbioe.2022.862951
_version_ 1784690426333102080
author Li, Jing-Chi
Xie, Tian-Hang
Zhang, Zhuang
Song, Zhe-Tao
Song, Yue-Ming
Zeng, Jian-Cheng
author_facet Li, Jing-Chi
Xie, Tian-Hang
Zhang, Zhuang
Song, Zhe-Tao
Song, Yue-Ming
Zeng, Jian-Cheng
author_sort Li, Jing-Chi
collection PubMed
description The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechanical effects of the mismatch between BEP and GB and the related risk of screw loosening. In this study, radiographic and demographic data of 56 patients treated by single segment oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) fixation were collected retrospectively, and the match sufficiency between BEP and GB was measured and presented as the grafted bony occupancy rate (GBOR). Data in patients with and without screw loosening were compared; regression analyses identified independent risk factors. OLIF with different GBORs was simulated in a previously constructed and validated lumbosacral model, and biomechanical indicators related to screw loosening were computed in surgical models. The radiographic review and numerical simulations showed that the coronal plane’s GBOR was significantly lower in screw loosening patients both in the cranial and caudal vertebral bodies; the decrease in the coronal plane’s GBOR has been proven to be an independent risk factor for screw loosening. In addition, numerical mechanical simulations showed that the poor match between BEP and GB will lead to stress concentration on both screws and bone-screw interfaces. Therefore, we can conclude that the mismatch between the BEP and GB will increase the risk of screw loosening by deteriorating local stress levels, and the increase in the GBOR by modifying the OLIF cage’s design may be an effective method to optimize the patient’s prognosis.
format Online
Article
Text
id pubmed-9023805
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90238052022-04-23 The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically Li, Jing-Chi Xie, Tian-Hang Zhang, Zhuang Song, Zhe-Tao Song, Yue-Ming Zeng, Jian-Cheng Front Bioeng Biotechnol Bioengineering and Biotechnology The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechanical effects of the mismatch between BEP and GB and the related risk of screw loosening. In this study, radiographic and demographic data of 56 patients treated by single segment oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) fixation were collected retrospectively, and the match sufficiency between BEP and GB was measured and presented as the grafted bony occupancy rate (GBOR). Data in patients with and without screw loosening were compared; regression analyses identified independent risk factors. OLIF with different GBORs was simulated in a previously constructed and validated lumbosacral model, and biomechanical indicators related to screw loosening were computed in surgical models. The radiographic review and numerical simulations showed that the coronal plane’s GBOR was significantly lower in screw loosening patients both in the cranial and caudal vertebral bodies; the decrease in the coronal plane’s GBOR has been proven to be an independent risk factor for screw loosening. In addition, numerical mechanical simulations showed that the poor match between BEP and GB will lead to stress concentration on both screws and bone-screw interfaces. Therefore, we can conclude that the mismatch between the BEP and GB will increase the risk of screw loosening by deteriorating local stress levels, and the increase in the GBOR by modifying the OLIF cage’s design may be an effective method to optimize the patient’s prognosis. Frontiers Media S.A. 2022-04-08 /pmc/articles/PMC9023805/ /pubmed/35464717 http://dx.doi.org/10.3389/fbioe.2022.862951 Text en Copyright © 2022 Li, Xie, Zhang, Song, Song and Zeng. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Li, Jing-Chi
Xie, Tian-Hang
Zhang, Zhuang
Song, Zhe-Tao
Song, Yue-Ming
Zeng, Jian-Cheng
The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_full The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_fullStr The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_full_unstemmed The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_short The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_sort mismatch between bony endplates and grafted bone increases screw loosening risk for olif patients with alsr fixation biomechanically
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9023805/
https://www.ncbi.nlm.nih.gov/pubmed/35464717
http://dx.doi.org/10.3389/fbioe.2022.862951
work_keys_str_mv AT lijingchi themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT xietianhang themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhangzhuang themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT songzhetao themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT songyueming themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zengjiancheng themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT lijingchi mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT xietianhang mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhangzhuang mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT songzhetao mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT songyueming mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zengjiancheng mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically