Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect

In a routine cataract operation cornea tissue may be damaged when an intra-ocular lens (IOL) injector of diameter between 1.467 and 2.011 mm is inserted through an empirically designed 2.2 mm corneal incision. We aimed to model and estimate the minimal length of the incision required to avoid wound...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Nan, Lockington, David, Wang, Lei, Ramaesh, Kanna, Luo, Xiaoyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9023857/
https://www.ncbi.nlm.nih.gov/pubmed/35464073
http://dx.doi.org/10.3389/fphys.2022.834214
_version_ 1784690431579127808
author Qi, Nan
Lockington, David
Wang, Lei
Ramaesh, Kanna
Luo, Xiaoyu
author_facet Qi, Nan
Lockington, David
Wang, Lei
Ramaesh, Kanna
Luo, Xiaoyu
author_sort Qi, Nan
collection PubMed
description In a routine cataract operation cornea tissue may be damaged when an intra-ocular lens (IOL) injector of diameter between 1.467 and 2.011 mm is inserted through an empirically designed 2.2 mm corneal incision. We aimed to model and estimate the minimal length of the incision required to avoid wound tear. It was assumed that the damage was caused by tissue fracture at the tips of the incision, and this fracture could be studied using damage and fracture mechanics. The criterion of the damage was caused by a tear governed by the critical energy release rate (ERR) G ( c ), which is tissue dependent. Analytical and numerical studies were both conducted indicating the possibility of a safe and effective incision in cataract surgery. Six commonly used IOL injection systems were examined. Our results suggested that the recommended 2.2 mm incision cannot be treated as a universal threshold. Quicker IOL insertion may reduce wound damage. It was also recommended to advance IOL injector via its minor axis, and to cut the tear preferably along the circumferential direction due to tissue orthotropy. This study provides useful information and a deeper insight into the potential for mechanical damage to the corneal wound in cataract surgery.
format Online
Article
Text
id pubmed-9023857
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90238572022-04-23 Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect Qi, Nan Lockington, David Wang, Lei Ramaesh, Kanna Luo, Xiaoyu Front Physiol Physiology In a routine cataract operation cornea tissue may be damaged when an intra-ocular lens (IOL) injector of diameter between 1.467 and 2.011 mm is inserted through an empirically designed 2.2 mm corneal incision. We aimed to model and estimate the minimal length of the incision required to avoid wound tear. It was assumed that the damage was caused by tissue fracture at the tips of the incision, and this fracture could be studied using damage and fracture mechanics. The criterion of the damage was caused by a tear governed by the critical energy release rate (ERR) G ( c ), which is tissue dependent. Analytical and numerical studies were both conducted indicating the possibility of a safe and effective incision in cataract surgery. Six commonly used IOL injection systems were examined. Our results suggested that the recommended 2.2 mm incision cannot be treated as a universal threshold. Quicker IOL insertion may reduce wound damage. It was also recommended to advance IOL injector via its minor axis, and to cut the tear preferably along the circumferential direction due to tissue orthotropy. This study provides useful information and a deeper insight into the potential for mechanical damage to the corneal wound in cataract surgery. Frontiers Media S.A. 2022-04-08 /pmc/articles/PMC9023857/ /pubmed/35464073 http://dx.doi.org/10.3389/fphys.2022.834214 Text en Copyright © 2022 Qi, Lockington, Wang, Ramaesh and Luo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Qi, Nan
Lockington, David
Wang, Lei
Ramaesh, Kanna
Luo, Xiaoyu
Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title_full Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title_fullStr Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title_full_unstemmed Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title_short Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect
title_sort estimations of critical clear corneal incisions required for lens insertion in cataract surgery: a mathematical aspect
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9023857/
https://www.ncbi.nlm.nih.gov/pubmed/35464073
http://dx.doi.org/10.3389/fphys.2022.834214
work_keys_str_mv AT qinan estimationsofcriticalclearcornealincisionsrequiredforlensinsertionincataractsurgeryamathematicalaspect
AT lockingtondavid estimationsofcriticalclearcornealincisionsrequiredforlensinsertionincataractsurgeryamathematicalaspect
AT wanglei estimationsofcriticalclearcornealincisionsrequiredforlensinsertionincataractsurgeryamathematicalaspect
AT ramaeshkanna estimationsofcriticalclearcornealincisionsrequiredforlensinsertionincataractsurgeryamathematicalaspect
AT luoxiaoyu estimationsofcriticalclearcornealincisionsrequiredforlensinsertionincataractsurgeryamathematicalaspect