Cargando…

A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria

This paper presents a dynamic-mode microcantilever sensor based on a gap method. The sensor has a V-shaped microcantilever and a fixed structure at a distance of 2 µm from its free end. The microcantilever is excited by applying an ac electric potential (3 V(p)) to its piezoelectric pads and vibrate...

Descripción completa

Detalles Bibliográficos
Autores principales: Fathy, Jino, Lai, Yongjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9025198/
https://www.ncbi.nlm.nih.gov/pubmed/35448254
http://dx.doi.org/10.3390/bios12040194
_version_ 1784690809766936576
author Fathy, Jino
Lai, Yongjun
author_facet Fathy, Jino
Lai, Yongjun
author_sort Fathy, Jino
collection PubMed
description This paper presents a dynamic-mode microcantilever sensor based on a gap method. The sensor has a V-shaped microcantilever and a fixed structure at a distance of 2 µm from its free end. The microcantilever is excited by applying an ac electric potential (3 V(p)) to its piezoelectric pads and vibrates at its fundamental resonant frequency. An independent ac electric potential (200 kHz, 15 V(pp)) is applied to the fixed structure. This creates a non-uniform electric field with its maxima at the gap and exerts a dielectrophoresis (DEP) force. The DEP force attracts and adsorbs the E. coli bacteria to the cantilever edge at the gap. The binding of the bacteria to the cantilever creates a shift in the resonant frequency of the microcantilever sensor, which is detected by a laser vibrometer. The real-time detection of E. coli bacteria samples, diluted in distilled water, was performed for concentrations of 10(5)–10(3) cells/mL and the real-time frequency shifts were −2264.3 to −755 Hz in 4 min, respectively. The tests were expanded to study the effect of the electric potential amplitude (10, 12, 15 V(pp)) and higher frequency shifts were observed for higher amplitudes.
format Online
Article
Text
id pubmed-9025198
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90251982022-04-23 A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria Fathy, Jino Lai, Yongjun Biosensors (Basel) Article This paper presents a dynamic-mode microcantilever sensor based on a gap method. The sensor has a V-shaped microcantilever and a fixed structure at a distance of 2 µm from its free end. The microcantilever is excited by applying an ac electric potential (3 V(p)) to its piezoelectric pads and vibrates at its fundamental resonant frequency. An independent ac electric potential (200 kHz, 15 V(pp)) is applied to the fixed structure. This creates a non-uniform electric field with its maxima at the gap and exerts a dielectrophoresis (DEP) force. The DEP force attracts and adsorbs the E. coli bacteria to the cantilever edge at the gap. The binding of the bacteria to the cantilever creates a shift in the resonant frequency of the microcantilever sensor, which is detected by a laser vibrometer. The real-time detection of E. coli bacteria samples, diluted in distilled water, was performed for concentrations of 10(5)–10(3) cells/mL and the real-time frequency shifts were −2264.3 to −755 Hz in 4 min, respectively. The tests were expanded to study the effect of the electric potential amplitude (10, 12, 15 V(pp)) and higher frequency shifts were observed for higher amplitudes. MDPI 2022-03-25 /pmc/articles/PMC9025198/ /pubmed/35448254 http://dx.doi.org/10.3390/bios12040194 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fathy, Jino
Lai, Yongjun
A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title_full A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title_fullStr A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title_full_unstemmed A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title_short A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria
title_sort v-shaped microcantilever sensor based on a gap method for real-time detection of e. coli bacteria
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9025198/
https://www.ncbi.nlm.nih.gov/pubmed/35448254
http://dx.doi.org/10.3390/bios12040194
work_keys_str_mv AT fathyjino avshapedmicrocantileversensorbasedonagapmethodforrealtimedetectionofecolibacteria
AT laiyongjun avshapedmicrocantileversensorbasedonagapmethodforrealtimedetectionofecolibacteria
AT fathyjino vshapedmicrocantileversensorbasedonagapmethodforrealtimedetectionofecolibacteria
AT laiyongjun vshapedmicrocantileversensorbasedonagapmethodforrealtimedetectionofecolibacteria