Cargando…
Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study
Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spin-echo T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9026945/ https://www.ncbi.nlm.nih.gov/pubmed/35454062 http://dx.doi.org/10.3390/diagnostics12041014 |
_version_ | 1784691237685559296 |
---|---|
author | Inoue, Katsuhiro Nakayama, Ryohei Isoshima, Shiho Takase, Shinichi Yamahata, Tsunehiro Umino, Maki Maeda, Masayuki Sakuma, Hajime |
author_facet | Inoue, Katsuhiro Nakayama, Ryohei Isoshima, Shiho Takase, Shinichi Yamahata, Tsunehiro Umino, Maki Maeda, Masayuki Sakuma, Hajime |
author_sort | Inoue, Katsuhiro |
collection | PubMed |
description | Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spin-echo T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE T1-BB VWI. Twenty cervical carotid plaque lesions in 19 patients with a plaque contrast ratio of > 1.3 compared to adjacent muscle were studied. Using the mean voxel value for the adjacent muscle multiplied by 1.3 as a threshold value, the semiautomated software exclusively segmented and measured the HSP volume. Manual and semiautomated HSP volumes were well correlated (r = 0.965). Regarding reproducibility, the inter-rater ICC was 0.959 (bias: 24.63, 95% limit of agreement: −96.07, 146.35) for the manual method and 0.998 (bias: 15.2, 95% limit of agreement: −17.83, 48.23) for the semiautomated method, indicating improved reproducibility by the semiautomated method compared to the manual method. The time required for semiautomated segmentation was significantly shorter than that of manual segmentation times (81.7 ± 7.8 s versus 189.5 ± 49.6 s; p < 0.01). The results obtained in this study demonstrate that the semiautomated segmentation method allows for reliable assessment of the HSP volume in patients with carotid plaque lesions, with reduced time and effort for the analysis. |
format | Online Article Text |
id | pubmed-9026945 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90269452022-04-23 Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study Inoue, Katsuhiro Nakayama, Ryohei Isoshima, Shiho Takase, Shinichi Yamahata, Tsunehiro Umino, Maki Maeda, Masayuki Sakuma, Hajime Diagnostics (Basel) Article Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spin-echo T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE T1-BB VWI. Twenty cervical carotid plaque lesions in 19 patients with a plaque contrast ratio of > 1.3 compared to adjacent muscle were studied. Using the mean voxel value for the adjacent muscle multiplied by 1.3 as a threshold value, the semiautomated software exclusively segmented and measured the HSP volume. Manual and semiautomated HSP volumes were well correlated (r = 0.965). Regarding reproducibility, the inter-rater ICC was 0.959 (bias: 24.63, 95% limit of agreement: −96.07, 146.35) for the manual method and 0.998 (bias: 15.2, 95% limit of agreement: −17.83, 48.23) for the semiautomated method, indicating improved reproducibility by the semiautomated method compared to the manual method. The time required for semiautomated segmentation was significantly shorter than that of manual segmentation times (81.7 ± 7.8 s versus 189.5 ± 49.6 s; p < 0.01). The results obtained in this study demonstrate that the semiautomated segmentation method allows for reliable assessment of the HSP volume in patients with carotid plaque lesions, with reduced time and effort for the analysis. MDPI 2022-04-17 /pmc/articles/PMC9026945/ /pubmed/35454062 http://dx.doi.org/10.3390/diagnostics12041014 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Inoue, Katsuhiro Nakayama, Ryohei Isoshima, Shiho Takase, Shinichi Yamahata, Tsunehiro Umino, Maki Maeda, Masayuki Sakuma, Hajime Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title | Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title_full | Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title_fullStr | Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title_full_unstemmed | Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title_short | Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study |
title_sort | semiautomated segmentation and volume measurements of cervical carotid high-signal plaques using 3d turbo spin-echo t1-weighted black-blood vessel wall imaging: a preliminary study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9026945/ https://www.ncbi.nlm.nih.gov/pubmed/35454062 http://dx.doi.org/10.3390/diagnostics12041014 |
work_keys_str_mv | AT inouekatsuhiro semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT nakayamaryohei semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT isoshimashiho semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT takaseshinichi semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT yamahatatsunehiro semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT uminomaki semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT maedamasayuki semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy AT sakumahajime semiautomatedsegmentationandvolumemeasurementsofcervicalcarotidhighsignalplaquesusing3dturbospinechot1weightedblackbloodvesselwallimagingapreliminarystudy |