Cargando…

An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients

Background: Non-invasive, bedside diagnostic tools are extremely important for tailo ring the management of respiratory failure patients. The use of electronic noses (ENs) for exhaled breath analysis has the potential to provide useful information for phenotyping different respiratory disorders and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bax, Carmen, Robbiani, Stefano, Zannin, Emanuela, Capelli, Laura, Ratti, Christian, Bonetti, Simone, Novelli, Luca, Raimondi, Federico, Di Marco, Fabiano, Dellacà, Raffaele L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9026987/
https://www.ncbi.nlm.nih.gov/pubmed/35453824
http://dx.doi.org/10.3390/diagnostics12040776
_version_ 1784691248276176896
author Bax, Carmen
Robbiani, Stefano
Zannin, Emanuela
Capelli, Laura
Ratti, Christian
Bonetti, Simone
Novelli, Luca
Raimondi, Federico
Di Marco, Fabiano
Dellacà, Raffaele L.
author_facet Bax, Carmen
Robbiani, Stefano
Zannin, Emanuela
Capelli, Laura
Ratti, Christian
Bonetti, Simone
Novelli, Luca
Raimondi, Federico
Di Marco, Fabiano
Dellacà, Raffaele L.
author_sort Bax, Carmen
collection PubMed
description Background: Non-invasive, bedside diagnostic tools are extremely important for tailo ring the management of respiratory failure patients. The use of electronic noses (ENs) for exhaled breath analysis has the potential to provide useful information for phenotyping different respiratory disorders and improving diagnosis, but their application in respiratory failure patients remains a challenge. We developed a novel measurement apparatus for analysing exhaled breath in such patients. Methods: The breath sampling apparatus uses hospital medical air and oxygen pipeline systems to control the fraction of inspired oxygen and prevent contamination of exhaled gas from ambient Volatile Organic Compounds (VOCs) It is designed to minimise the dead space and respiratory load imposed on patients. Breath odour fingerprints were assessed using a commercial EN with custom MOX sensors. We carried out a feasibility study on 33 SARS-CoV-2 patients (25 with respiratory failure and 8 asymptomatic) and 22 controls to gather data on tolerability and for a preliminary assessment of sensitivity and specificity. The most significant features for the discrimination between breath-odour fingerprints from respiratory failure patients and controls were identified using the Boruta algorithm and then implemented in the development of a support vector machine (SVM) classification model. Results: The novel sampling system was well-tolerated by all patients. The SVM differentiated between respiratory failure patients and controls with an accuracy of 0.81 (area under the ROC curve) and a sensitivity and specificity of 0.920 and 0.682, respectively. The selected features were significantly different in SARS-CoV-2 patients with respiratory failure versus controls and asymptomatic SARS-CoV-2 patients (p < 0.001 and 0.046, respectively). Conclusions: the developed system is suitable for the collection of exhaled breath samples from respiratory failure patients. Our preliminary results suggest that breath-odour fingerprints may be sensitive markers of lung disease severity and aetiology.
format Online
Article
Text
id pubmed-9026987
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90269872022-04-23 An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients Bax, Carmen Robbiani, Stefano Zannin, Emanuela Capelli, Laura Ratti, Christian Bonetti, Simone Novelli, Luca Raimondi, Federico Di Marco, Fabiano Dellacà, Raffaele L. Diagnostics (Basel) Article Background: Non-invasive, bedside diagnostic tools are extremely important for tailo ring the management of respiratory failure patients. The use of electronic noses (ENs) for exhaled breath analysis has the potential to provide useful information for phenotyping different respiratory disorders and improving diagnosis, but their application in respiratory failure patients remains a challenge. We developed a novel measurement apparatus for analysing exhaled breath in such patients. Methods: The breath sampling apparatus uses hospital medical air and oxygen pipeline systems to control the fraction of inspired oxygen and prevent contamination of exhaled gas from ambient Volatile Organic Compounds (VOCs) It is designed to minimise the dead space and respiratory load imposed on patients. Breath odour fingerprints were assessed using a commercial EN with custom MOX sensors. We carried out a feasibility study on 33 SARS-CoV-2 patients (25 with respiratory failure and 8 asymptomatic) and 22 controls to gather data on tolerability and for a preliminary assessment of sensitivity and specificity. The most significant features for the discrimination between breath-odour fingerprints from respiratory failure patients and controls were identified using the Boruta algorithm and then implemented in the development of a support vector machine (SVM) classification model. Results: The novel sampling system was well-tolerated by all patients. The SVM differentiated between respiratory failure patients and controls with an accuracy of 0.81 (area under the ROC curve) and a sensitivity and specificity of 0.920 and 0.682, respectively. The selected features were significantly different in SARS-CoV-2 patients with respiratory failure versus controls and asymptomatic SARS-CoV-2 patients (p < 0.001 and 0.046, respectively). Conclusions: the developed system is suitable for the collection of exhaled breath samples from respiratory failure patients. Our preliminary results suggest that breath-odour fingerprints may be sensitive markers of lung disease severity and aetiology. MDPI 2022-03-22 /pmc/articles/PMC9026987/ /pubmed/35453824 http://dx.doi.org/10.3390/diagnostics12040776 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bax, Carmen
Robbiani, Stefano
Zannin, Emanuela
Capelli, Laura
Ratti, Christian
Bonetti, Simone
Novelli, Luca
Raimondi, Federico
Di Marco, Fabiano
Dellacà, Raffaele L.
An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title_full An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title_fullStr An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title_full_unstemmed An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title_short An Experimental Apparatus for E-Nose Breath Analysis in Respiratory Failure Patients
title_sort experimental apparatus for e-nose breath analysis in respiratory failure patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9026987/
https://www.ncbi.nlm.nih.gov/pubmed/35453824
http://dx.doi.org/10.3390/diagnostics12040776
work_keys_str_mv AT baxcarmen anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT robbianistefano anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT zanninemanuela anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT capellilaura anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT rattichristian anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT bonettisimone anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT novelliluca anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT raimondifederico anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT dimarcofabiano anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT dellacaraffaelel anexperimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT baxcarmen experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT robbianistefano experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT zanninemanuela experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT capellilaura experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT rattichristian experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT bonettisimone experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT novelliluca experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT raimondifederico experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT dimarcofabiano experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients
AT dellacaraffaelel experimentalapparatusforenosebreathanalysisinrespiratoryfailurepatients