Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods
Coarse aggregate in concrete is basically free from sulfate corrosion. If the influence of the coarse aggregate in the concrete is not eliminated, the change amount of the concrete ultrasonic pulse velocity value is directly used to evaluate the damage degree of sulfate corrosion in the concrete, an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027067/ https://www.ncbi.nlm.nih.gov/pubmed/35459021 http://dx.doi.org/10.3390/s22083037 |
_version_ | 1784691269196316672 |
---|---|
author | Liu, Dunwen Gong, Chun Tang, Yu Jian, Yinghua Cao, Kunpeng Chen, Haofei |
author_facet | Liu, Dunwen Gong, Chun Tang, Yu Jian, Yinghua Cao, Kunpeng Chen, Haofei |
author_sort | Liu, Dunwen |
collection | PubMed |
description | Coarse aggregate in concrete is basically free from sulfate corrosion. If the influence of the coarse aggregate in the concrete is not eliminated, the change amount of the concrete ultrasonic pulse velocity value is directly used to evaluate the damage degree of sulfate corrosion in the concrete, and the results are often inaccurate. This paper presents an evaluation method of corrosion damage for the sulfate-attacked concrete by CT, ultrasonic velocity testing and AHP methods. CT was used to extract the coarse aggregate information in the specimen, and the proportion of coarse aggregate on the ultrasonic test line was calculated based on CT image analysis. Then, the correction value of ultrasonic pulse velocity (UPV) of the concrete structure was calculated, and the sulfate corrosion degree of concrete structure was evaluated using the analytic hierarchy process (AHP). The results show that the evaluation method proposed in this paper could more accurately evaluate the corrosion damage in the sulfate-attacked concrete structures, and the evaluation results were more in line with reality. |
format | Online Article Text |
id | pubmed-9027067 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90270672022-04-23 Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods Liu, Dunwen Gong, Chun Tang, Yu Jian, Yinghua Cao, Kunpeng Chen, Haofei Sensors (Basel) Article Coarse aggregate in concrete is basically free from sulfate corrosion. If the influence of the coarse aggregate in the concrete is not eliminated, the change amount of the concrete ultrasonic pulse velocity value is directly used to evaluate the damage degree of sulfate corrosion in the concrete, and the results are often inaccurate. This paper presents an evaluation method of corrosion damage for the sulfate-attacked concrete by CT, ultrasonic velocity testing and AHP methods. CT was used to extract the coarse aggregate information in the specimen, and the proportion of coarse aggregate on the ultrasonic test line was calculated based on CT image analysis. Then, the correction value of ultrasonic pulse velocity (UPV) of the concrete structure was calculated, and the sulfate corrosion degree of concrete structure was evaluated using the analytic hierarchy process (AHP). The results show that the evaluation method proposed in this paper could more accurately evaluate the corrosion damage in the sulfate-attacked concrete structures, and the evaluation results were more in line with reality. MDPI 2022-04-15 /pmc/articles/PMC9027067/ /pubmed/35459021 http://dx.doi.org/10.3390/s22083037 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Dunwen Gong, Chun Tang, Yu Jian, Yinghua Cao, Kunpeng Chen, Haofei Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title | Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title_full | Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title_fullStr | Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title_full_unstemmed | Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title_short | Evaluation of Corrosion Damage in Sulfate-Attacked Concrete by CT, Ultrasonic Pulse Velocity Testing and AHP Methods |
title_sort | evaluation of corrosion damage in sulfate-attacked concrete by ct, ultrasonic pulse velocity testing and ahp methods |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027067/ https://www.ncbi.nlm.nih.gov/pubmed/35459021 http://dx.doi.org/10.3390/s22083037 |
work_keys_str_mv | AT liudunwen evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods AT gongchun evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods AT tangyu evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods AT jianyinghua evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods AT caokunpeng evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods AT chenhaofei evaluationofcorrosiondamageinsulfateattackedconcretebyctultrasonicpulsevelocitytestingandahpmethods |