Cargando…

Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis

The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 film...

Descripción completa

Detalles Bibliográficos
Autores principales: Abu Mhanna, Hamad Yahia, Omar, Ahmad Fairuz, Radzi, Yasmin Md, Akhdar, Hanan Fawaz, Al Ewaidat, Haytham
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027090/
https://www.ncbi.nlm.nih.gov/pubmed/35454597
http://dx.doi.org/10.3390/ma15082903
_version_ 1784691274535665664
author Abu Mhanna, Hamad Yahia
Omar, Ahmad Fairuz
Radzi, Yasmin Md
Akhdar, Hanan Fawaz
Al Ewaidat, Haytham
author_facet Abu Mhanna, Hamad Yahia
Omar, Ahmad Fairuz
Radzi, Yasmin Md
Akhdar, Hanan Fawaz
Al Ewaidat, Haytham
author_sort Abu Mhanna, Hamad Yahia
collection PubMed
description The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm(2). The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon. The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples. The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at λ = 641.74 nm and λ = 585.98 nm for X-rays, and at λ = 637.93 nm and λ = 584.45 nm for SUV-rays, respectively. According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays. In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value. Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes.
format Online
Article
Text
id pubmed-9027090
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90270902022-04-23 Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis Abu Mhanna, Hamad Yahia Omar, Ahmad Fairuz Radzi, Yasmin Md Akhdar, Hanan Fawaz Al Ewaidat, Haytham Materials (Basel) Article The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm(2). The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon. The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples. The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at λ = 641.74 nm and λ = 585.98 nm for X-rays, and at λ = 637.93 nm and λ = 584.45 nm for SUV-rays, respectively. According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays. In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value. Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes. MDPI 2022-04-15 /pmc/articles/PMC9027090/ /pubmed/35454597 http://dx.doi.org/10.3390/ma15082903 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abu Mhanna, Hamad Yahia
Omar, Ahmad Fairuz
Radzi, Yasmin Md
Akhdar, Hanan Fawaz
Al Ewaidat, Haytham
Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title_full Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title_fullStr Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title_full_unstemmed Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title_short Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
title_sort expired ebt3 films’ sensitivity for the measurement of x-ray and uv radiation: an optical analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027090/
https://www.ncbi.nlm.nih.gov/pubmed/35454597
http://dx.doi.org/10.3390/ma15082903
work_keys_str_mv AT abumhannahamadyahia expiredebt3filmssensitivityforthemeasurementofxrayanduvradiationanopticalanalysis
AT omarahmadfairuz expiredebt3filmssensitivityforthemeasurementofxrayanduvradiationanopticalanalysis
AT radziyasminmd expiredebt3filmssensitivityforthemeasurementofxrayanduvradiationanopticalanalysis
AT akhdarhananfawaz expiredebt3filmssensitivityforthemeasurementofxrayanduvradiationanopticalanalysis
AT alewaidathaytham expiredebt3filmssensitivityforthemeasurementofxrayanduvradiationanopticalanalysis