Cargando…

A Novel Approach to Immediate Implants: The CastleWall Surgical Technique

Objective: The purpose of this study was to investigate the volumetric stability around immediate implants, in which a 360-degree socket-shield was retained using the CastleWall Surgical Technique (CWST). Material and methods: This retrospective study examined the results of the CWST used for 25 con...

Descripción completa

Detalles Bibliográficos
Autor principal: Castle, Cameron
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027629/
https://www.ncbi.nlm.nih.gov/pubmed/35448056
http://dx.doi.org/10.3390/dj10040062
_version_ 1784691414374809600
author Castle, Cameron
author_facet Castle, Cameron
author_sort Castle, Cameron
collection PubMed
description Objective: The purpose of this study was to investigate the volumetric stability around immediate implants, in which a 360-degree socket-shield was retained using the CastleWall Surgical Technique (CWST). Material and methods: This retrospective study examined the results of the CWST used for 25 consecutive patients, involving 31 immediate implants. Silicone impressions taken prior to extraction, and at a review appointment were converted to STL files and compared. The median follow-up time was 14.2 ± 5.5 months. Volumetric changes and gingival recession on both buccal and lingual sites were measured. Papillary height changes were also evaluated from available photographs taken before and after treatment. Patients in the study completed a Visual Analogue Scale (VAS) for evaluation of post-operative discomfort and overall satisfaction with this procedure. Results: All implants integrated successfully without complications. Mean loss of buccal and lingual tissue was 0.30 ± 0.32 mm and 0.17 ± 0.27 mm, respectively. Mean recession at the mid-buccal and mid-lingual gingival margin was 0.66 ± 0.64 mm and 0.87 ± 0.84 mm, respectively. Mean recession of the mesial and distal papilla was 0.26 ± 0.55 mm and 0.29 ± 0.52 mm, respectively. Patients reported 97.74 ± 5.60% satisfaction with this procedure using the Visual Analogue Scale (VAS), with minimal post-operative discomfort. Conclusions: The results of this study showed excellent soft tissue stability and aesthetics were achieved using the CWST, with minimal postoperative pain. The other main advantage of retaining a 360-degree socket-shield, is there is more available surface area to lock the implant to the shield to prevent shield migration over time.
format Online
Article
Text
id pubmed-9027629
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90276292022-04-23 A Novel Approach to Immediate Implants: The CastleWall Surgical Technique Castle, Cameron Dent J (Basel) Article Objective: The purpose of this study was to investigate the volumetric stability around immediate implants, in which a 360-degree socket-shield was retained using the CastleWall Surgical Technique (CWST). Material and methods: This retrospective study examined the results of the CWST used for 25 consecutive patients, involving 31 immediate implants. Silicone impressions taken prior to extraction, and at a review appointment were converted to STL files and compared. The median follow-up time was 14.2 ± 5.5 months. Volumetric changes and gingival recession on both buccal and lingual sites were measured. Papillary height changes were also evaluated from available photographs taken before and after treatment. Patients in the study completed a Visual Analogue Scale (VAS) for evaluation of post-operative discomfort and overall satisfaction with this procedure. Results: All implants integrated successfully without complications. Mean loss of buccal and lingual tissue was 0.30 ± 0.32 mm and 0.17 ± 0.27 mm, respectively. Mean recession at the mid-buccal and mid-lingual gingival margin was 0.66 ± 0.64 mm and 0.87 ± 0.84 mm, respectively. Mean recession of the mesial and distal papilla was 0.26 ± 0.55 mm and 0.29 ± 0.52 mm, respectively. Patients reported 97.74 ± 5.60% satisfaction with this procedure using the Visual Analogue Scale (VAS), with minimal post-operative discomfort. Conclusions: The results of this study showed excellent soft tissue stability and aesthetics were achieved using the CWST, with minimal postoperative pain. The other main advantage of retaining a 360-degree socket-shield, is there is more available surface area to lock the implant to the shield to prevent shield migration over time. MDPI 2022-04-06 /pmc/articles/PMC9027629/ /pubmed/35448056 http://dx.doi.org/10.3390/dj10040062 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Castle, Cameron
A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title_full A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title_fullStr A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title_full_unstemmed A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title_short A Novel Approach to Immediate Implants: The CastleWall Surgical Technique
title_sort novel approach to immediate implants: the castlewall surgical technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027629/
https://www.ncbi.nlm.nih.gov/pubmed/35448056
http://dx.doi.org/10.3390/dj10040062
work_keys_str_mv AT castlecameron anovelapproachtoimmediateimplantsthecastlewallsurgicaltechnique
AT castlecameron novelapproachtoimmediateimplantsthecastlewallsurgicaltechnique