Cargando…

Initial Experience with Fenestrated Physician-Modified Stent Grafts Using 3D Aortic Templates

The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic...

Descripción completa

Detalles Bibliográficos
Autores principales: Rynio, Paweł, Jedrzejczak, Tomasz, Rybicka, Anita, Milner, Ross, Gutowski, Piotr, Kazimierczak, Arkadiusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027705/
https://www.ncbi.nlm.nih.gov/pubmed/35456273
http://dx.doi.org/10.3390/jcm11082180
Descripción
Sumario:The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic model. The inclusion criteria were juxtarenal and suprarenal aortic aneurysms, type IV thoracoabdominal aneurysms, and type IA endoleak after endovascular aortic repair. In asymptomatic patients, the diameter threshold for aneurysm repair was 5.5 cm in males and 5.0 cm in females. 3D aortic templates were prepared from the patient’s computed tomography angiography scans and sterilized before use in the operating suite. Forty-three stent grafts were modified with the use of a 3D printing template. A total of 162 reinforced fenestrations (37 celiac, 43 right renal, 39 left renal, 43 superior mesenteric) with a mean of 3.8 per patient were performed. All PMEGs had a posterior reducing-diameter tie and a preloaded guidewire. The mean modification time was 86 ± 12 min. The mean follow-up was 14 ± 12 months. The 30-day mortality was 12%. During the follow-up period, the patency rate was 95% per the superior mesenteric artery, 93% per right renal artery, 95% per left renal artery, and 89% per celiac trunk. Twelve (28%) patients had endoleak, of which type I or III was present in 5 (12%) patients, and type II in 7 (16%). 3D printing can be successfully integrated into the physician’s everyday practice of stent graft modification. However, the use of this approach in centers without experience performing complex aortic procedures results in worse surgical metrics than those previously reported.