Cargando…

Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy

Detection and criticality assessment of defects appearing in inaccessible locations in pipelines pose a great challenge for many industries. Inspection methods which allow for remote defect detection and accurate characterisation are needed. Guided wave testing (GWT) is capable of screening large le...

Descripción completa

Detalles Bibliográficos
Autores principales: Szlaszynski, Filip, Lowe, Michael J. S., Huthwaite, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9028324/
https://www.ncbi.nlm.nih.gov/pubmed/35458958
http://dx.doi.org/10.3390/s22082973
_version_ 1784691588806475776
author Szlaszynski, Filip
Lowe, Michael J. S.
Huthwaite, Peter
author_facet Szlaszynski, Filip
Lowe, Michael J. S.
Huthwaite, Peter
author_sort Szlaszynski, Filip
collection PubMed
description Detection and criticality assessment of defects appearing in inaccessible locations in pipelines pose a great challenge for many industries. Inspection methods which allow for remote defect detection and accurate characterisation are needed. Guided wave testing (GWT) is capable of screening large lengths of pipes from a single device position, however it provides very limited individual feature characterisation. This paper adapts Plane Wave Imaging (PWI) to pipe GWT to improve defect characterization for inspection in nearby locations such as a few metres from the transducers. PWI performance is evaluated using finite element (FE) and experimental studies, and it is compared to other popular synthetic focusing imaging techniques. The study is concerned with part-circumferential part-depth planar cracks. It is shown that PWI achieves superior resolution compared to the common source method (CSM) and comparable resolution to the total focusing method (TFM). The techniques involving plane wave acquisition (PWI and CSM) are found to substantially outperform methods based on full matrix capture (FMC) in terms of signal-to-noise ratio (SNR). Therefore, it is concluded that PWI which achieves good resolution and high SNR is a more attractive choice for pipe GWT, compared to other considered techniques. Subsequently, a novel PWI transduction setup is proposed, and it is shown to suppresses the transmission of unwanted S0 mode, which further improves SNR of PWI.
format Online
Article
Text
id pubmed-9028324
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90283242022-04-23 Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy Szlaszynski, Filip Lowe, Michael J. S. Huthwaite, Peter Sensors (Basel) Article Detection and criticality assessment of defects appearing in inaccessible locations in pipelines pose a great challenge for many industries. Inspection methods which allow for remote defect detection and accurate characterisation are needed. Guided wave testing (GWT) is capable of screening large lengths of pipes from a single device position, however it provides very limited individual feature characterisation. This paper adapts Plane Wave Imaging (PWI) to pipe GWT to improve defect characterization for inspection in nearby locations such as a few metres from the transducers. PWI performance is evaluated using finite element (FE) and experimental studies, and it is compared to other popular synthetic focusing imaging techniques. The study is concerned with part-circumferential part-depth planar cracks. It is shown that PWI achieves superior resolution compared to the common source method (CSM) and comparable resolution to the total focusing method (TFM). The techniques involving plane wave acquisition (PWI and CSM) are found to substantially outperform methods based on full matrix capture (FMC) in terms of signal-to-noise ratio (SNR). Therefore, it is concluded that PWI which achieves good resolution and high SNR is a more attractive choice for pipe GWT, compared to other considered techniques. Subsequently, a novel PWI transduction setup is proposed, and it is shown to suppresses the transmission of unwanted S0 mode, which further improves SNR of PWI. MDPI 2022-04-13 /pmc/articles/PMC9028324/ /pubmed/35458958 http://dx.doi.org/10.3390/s22082973 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Szlaszynski, Filip
Lowe, Michael J. S.
Huthwaite, Peter
Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title_full Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title_fullStr Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title_full_unstemmed Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title_short Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy
title_sort short range pipe guided wave testing using sh0 plane wave imaging for improved quantification accuracy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9028324/
https://www.ncbi.nlm.nih.gov/pubmed/35458958
http://dx.doi.org/10.3390/s22082973
work_keys_str_mv AT szlaszynskifilip shortrangepipeguidedwavetestingusingsh0planewaveimagingforimprovedquantificationaccuracy
AT lowemichaeljs shortrangepipeguidedwavetestingusingsh0planewaveimagingforimprovedquantificationaccuracy
AT huthwaitepeter shortrangepipeguidedwavetestingusingsh0planewaveimagingforimprovedquantificationaccuracy