Cargando…
Design of automatic urine collection system for medical system applications
BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving the toilet environment at the hospitals and public...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
IOS Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9028661/ https://www.ncbi.nlm.nih.gov/pubmed/35124588 http://dx.doi.org/10.3233/THC-228010 |
_version_ | 1784691677206675456 |
---|---|
author | Cheng, Li Hao, Chenru Wang, Yanpeng Zhang, Jingjing Wen, Yunlong Chi, Ziqiang Li, Xiuyuan Yang, Haibo Wu, Yanru Guo, Lisha Zhao, Ruibin |
author_facet | Cheng, Li Hao, Chenru Wang, Yanpeng Zhang, Jingjing Wen, Yunlong Chi, Ziqiang Li, Xiuyuan Yang, Haibo Wu, Yanru Guo, Lisha Zhao, Ruibin |
author_sort | Cheng, Li |
collection | PubMed |
description | BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving the toilet environment at the hospitals and public physical examination centers, this paper designs an automatic urine collection system. It can automatically adjust the position of the urine cup with an infrared remote controller, or manually, adjust the position of the urine cup in special situations according to the needs of the user. It also has an alarm function. METHODS: The overall size and shape are designed based on the squatting pan, suitable for disposable plastic urine cups of different shapes and sizes. It can realize the automatic collection of midstream urine, manual collection in exceptional cases, emergency stops, and rescue calls. RESULTS: Through the trial survey, there was a significant difference between the statistical results of using the device and not using the device ([Formula: see text] 13.937, [Formula: see text] 0.000). 96% of the subjects thought that the design of the system was reasonable, 22% thought that it was inconvenient to use, and 91.7% of the medical staff thought that the system met the sampling requirements. CONCLUSIONS: Therefore, the trial evaluation is satisfactory, and the proposed collection system is suitable for use in hospitals at all levels and public health examination centers with a large amount of inspection. |
format | Online Article Text |
id | pubmed-9028661 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | IOS Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-90286612022-05-06 Design of automatic urine collection system for medical system applications Cheng, Li Hao, Chenru Wang, Yanpeng Zhang, Jingjing Wen, Yunlong Chi, Ziqiang Li, Xiuyuan Yang, Haibo Wu, Yanru Guo, Lisha Zhao, Ruibin Technol Health Care Research Article BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving the toilet environment at the hospitals and public physical examination centers, this paper designs an automatic urine collection system. It can automatically adjust the position of the urine cup with an infrared remote controller, or manually, adjust the position of the urine cup in special situations according to the needs of the user. It also has an alarm function. METHODS: The overall size and shape are designed based on the squatting pan, suitable for disposable plastic urine cups of different shapes and sizes. It can realize the automatic collection of midstream urine, manual collection in exceptional cases, emergency stops, and rescue calls. RESULTS: Through the trial survey, there was a significant difference between the statistical results of using the device and not using the device ([Formula: see text] 13.937, [Formula: see text] 0.000). 96% of the subjects thought that the design of the system was reasonable, 22% thought that it was inconvenient to use, and 91.7% of the medical staff thought that the system met the sampling requirements. CONCLUSIONS: Therefore, the trial evaluation is satisfactory, and the proposed collection system is suitable for use in hospitals at all levels and public health examination centers with a large amount of inspection. IOS Press 2022-02-25 /pmc/articles/PMC9028661/ /pubmed/35124588 http://dx.doi.org/10.3233/THC-228010 Text en © 2022 – The authors. Published by IOS Press. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial (CC BY-NC 4.0) License (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cheng, Li Hao, Chenru Wang, Yanpeng Zhang, Jingjing Wen, Yunlong Chi, Ziqiang Li, Xiuyuan Yang, Haibo Wu, Yanru Guo, Lisha Zhao, Ruibin Design of automatic urine collection system for medical system applications |
title | Design of automatic urine collection system for medical system applications |
title_full | Design of automatic urine collection system for medical system applications |
title_fullStr | Design of automatic urine collection system for medical system applications |
title_full_unstemmed | Design of automatic urine collection system for medical system applications |
title_short | Design of automatic urine collection system for medical system applications |
title_sort | design of automatic urine collection system for medical system applications |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9028661/ https://www.ncbi.nlm.nih.gov/pubmed/35124588 http://dx.doi.org/10.3233/THC-228010 |
work_keys_str_mv | AT chengli designofautomaticurinecollectionsystemformedicalsystemapplications AT haochenru designofautomaticurinecollectionsystemformedicalsystemapplications AT wangyanpeng designofautomaticurinecollectionsystemformedicalsystemapplications AT zhangjingjing designofautomaticurinecollectionsystemformedicalsystemapplications AT wenyunlong designofautomaticurinecollectionsystemformedicalsystemapplications AT chiziqiang designofautomaticurinecollectionsystemformedicalsystemapplications AT lixiuyuan designofautomaticurinecollectionsystemformedicalsystemapplications AT yanghaibo designofautomaticurinecollectionsystemformedicalsystemapplications AT wuyanru designofautomaticurinecollectionsystemformedicalsystemapplications AT guolisha designofautomaticurinecollectionsystemformedicalsystemapplications AT zhaoruibin designofautomaticurinecollectionsystemformedicalsystemapplications |