Cargando…

One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film

A highly sensitive tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor based on a graphene-titania-Nafion composite film has been prepared in a simple one-step manner. In the present work, a highly concentrated 0.1 M Ru(bpy)(3)(2+) solution was mixed wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang Jung, Lee, Don Hui, Lee, Won-Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9029434/
https://www.ncbi.nlm.nih.gov/pubmed/35459048
http://dx.doi.org/10.3390/s22083064
_version_ 1784691877176410112
author Lee, Sang Jung
Lee, Don Hui
Lee, Won-Yong
author_facet Lee, Sang Jung
Lee, Don Hui
Lee, Won-Yong
author_sort Lee, Sang Jung
collection PubMed
description A highly sensitive tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor based on a graphene-titania-Nafion composite film has been prepared in a simple one-step manner. In the present work, a highly concentrated 0.1 M Ru(bpy)(3)(2+) solution was mixed with an as-prepared graphene-titania-Nafion composite solution (1:20, v/v), and then a small aliquot (2 µL) of the resulting mixture solution was cast on a glassy carbon electrode surface. This one-step process for the construction of an ECL sensor shortens the fabrication time and leads to reproducible ECL signals. Due to the synergistic effect of conductive graphene and mesoporous sol-gel derived titania-Nafion composite, the present ECL sensor leads to a highly sensitive detection of tripropylamine from 1.0 × 10(−8) M to 2.0 × 10(−3) M with a detection limit of 0.8 nM (S/N = 3), which is lower in comparison to that of the ECL sensor based on the corresponding ECL sensor based on the titania-Nafion composite containing carbon nanotube. The present ECL sensor also shows a good response for nicotinamide adenine dinucleotide hydrogen (NADH) from 1.0 × 10(−6) M to 1.0 × 10(−3) M with a detection limit of 0.4 µM (S/N = 3). Thus, the present ECL sensor can offer potential benefits in the development of dehydrogenase-based biosensors.
format Online
Article
Text
id pubmed-9029434
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90294342022-04-23 One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film Lee, Sang Jung Lee, Don Hui Lee, Won-Yong Sensors (Basel) Article A highly sensitive tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor based on a graphene-titania-Nafion composite film has been prepared in a simple one-step manner. In the present work, a highly concentrated 0.1 M Ru(bpy)(3)(2+) solution was mixed with an as-prepared graphene-titania-Nafion composite solution (1:20, v/v), and then a small aliquot (2 µL) of the resulting mixture solution was cast on a glassy carbon electrode surface. This one-step process for the construction of an ECL sensor shortens the fabrication time and leads to reproducible ECL signals. Due to the synergistic effect of conductive graphene and mesoporous sol-gel derived titania-Nafion composite, the present ECL sensor leads to a highly sensitive detection of tripropylamine from 1.0 × 10(−8) M to 2.0 × 10(−3) M with a detection limit of 0.8 nM (S/N = 3), which is lower in comparison to that of the ECL sensor based on the corresponding ECL sensor based on the titania-Nafion composite containing carbon nanotube. The present ECL sensor also shows a good response for nicotinamide adenine dinucleotide hydrogen (NADH) from 1.0 × 10(−6) M to 1.0 × 10(−3) M with a detection limit of 0.4 µM (S/N = 3). Thus, the present ECL sensor can offer potential benefits in the development of dehydrogenase-based biosensors. MDPI 2022-04-15 /pmc/articles/PMC9029434/ /pubmed/35459048 http://dx.doi.org/10.3390/s22083064 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Sang Jung
Lee, Don Hui
Lee, Won-Yong
One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title_full One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title_fullStr One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title_full_unstemmed One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title_short One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
title_sort one-step fabrication of highly sensitive tris(2,2′-bipyridyl)ruthenium(ii) electrogenerated chemiluminescence sensor based on graphene-titania-nafion composite film
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9029434/
https://www.ncbi.nlm.nih.gov/pubmed/35459048
http://dx.doi.org/10.3390/s22083064
work_keys_str_mv AT leesangjung onestepfabricationofhighlysensitivetris22bipyridylrutheniumiielectrogeneratedchemiluminescencesensorbasedongraphenetitanianafioncompositefilm
AT leedonhui onestepfabricationofhighlysensitivetris22bipyridylrutheniumiielectrogeneratedchemiluminescencesensorbasedongraphenetitanianafioncompositefilm
AT leewonyong onestepfabricationofhighlysensitivetris22bipyridylrutheniumiielectrogeneratedchemiluminescencesensorbasedongraphenetitanianafioncompositefilm