Cargando…

Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors

Low-energy X-rays have a predominant role in medical diagnostic applications, grown tremendously during recent Covid-19 pandemic times. Synthesis of stable, PMMA/polystyrene-BiI(3) composites has been done through a facile, low-cost, dry-tumble mixing technique for direct X-ray detector applications...

Descripción completa

Detalles Bibliográficos
Autores principales: Chaudhari, Ritu, Kant, Chhaya Ravi, Garg, Alka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9030686/
https://www.ncbi.nlm.nih.gov/pubmed/35492383
http://dx.doi.org/10.1557/s43579-022-00185-6
_version_ 1784692202587291648
author Chaudhari, Ritu
Kant, Chhaya Ravi
Garg, Alka
author_facet Chaudhari, Ritu
Kant, Chhaya Ravi
Garg, Alka
author_sort Chaudhari, Ritu
collection PubMed
description Low-energy X-rays have a predominant role in medical diagnostic applications, grown tremendously during recent Covid-19 pandemic times. Synthesis of stable, PMMA/polystyrene-BiI(3) composites has been done through a facile, low-cost, dry-tumble mixing technique for direct X-ray detector applications. Comparative analysis of structural, optical, and photocurrent responses upon irradiation with low-energy X-rays (30 and 60 kV) ensue that PS-BiI(3) demonstrates high SNR 3300, sensitivity 189 µC Gy(−1) cm(−3) and fast response time 30 ms, at dose rate 1.68 mGy s(−1), affirming the composite to be prospective candidate for low-energy, room-temperature, direct X-ray detectors under low bias conditions. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1557/s43579-022-00185-6.
format Online
Article
Text
id pubmed-9030686
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-90306862022-04-25 Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors Chaudhari, Ritu Kant, Chhaya Ravi Garg, Alka MRS Commun Research Letter Low-energy X-rays have a predominant role in medical diagnostic applications, grown tremendously during recent Covid-19 pandemic times. Synthesis of stable, PMMA/polystyrene-BiI(3) composites has been done through a facile, low-cost, dry-tumble mixing technique for direct X-ray detector applications. Comparative analysis of structural, optical, and photocurrent responses upon irradiation with low-energy X-rays (30 and 60 kV) ensue that PS-BiI(3) demonstrates high SNR 3300, sensitivity 189 µC Gy(−1) cm(−3) and fast response time 30 ms, at dose rate 1.68 mGy s(−1), affirming the composite to be prospective candidate for low-energy, room-temperature, direct X-ray detectors under low bias conditions. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1557/s43579-022-00185-6. Springer International Publishing 2022-04-22 2022 /pmc/articles/PMC9030686/ /pubmed/35492383 http://dx.doi.org/10.1557/s43579-022-00185-6 Text en © The Author(s), under exclusive licence to The Materials Research Society 2022 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Letter
Chaudhari, Ritu
Kant, Chhaya Ravi
Garg, Alka
Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title_full Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title_fullStr Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title_full_unstemmed Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title_short Polymer-BiI(3) composites for high-performance, room-temperature, direct X-ray detectors
title_sort polymer-bii(3) composites for high-performance, room-temperature, direct x-ray detectors
topic Research Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9030686/
https://www.ncbi.nlm.nih.gov/pubmed/35492383
http://dx.doi.org/10.1557/s43579-022-00185-6
work_keys_str_mv AT chaudhariritu polymerbii3compositesforhighperformanceroomtemperaturedirectxraydetectors
AT kantchhayaravi polymerbii3compositesforhighperformanceroomtemperaturedirectxraydetectors
AT gargalka polymerbii3compositesforhighperformanceroomtemperaturedirectxraydetectors