Cargando…

Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring

In this paper, the performance of three recent algorithms for the frequency-response enhancement of microwave resonant sensors are compared. The first one, a single-step algorithm, is based on a couple of direct-inverse Fourier transforms, giving a densely sampled response as a result. The second al...

Descripción completa

Detalles Bibliográficos
Autores principales: Buonanno, Giovanni, Brancaccio, Adriana, Costanzo, Sandra, Solimene, Raffaele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9031377/
https://www.ncbi.nlm.nih.gov/pubmed/35447716
http://dx.doi.org/10.3390/bioengineering9040156
_version_ 1784692374762422272
author Buonanno, Giovanni
Brancaccio, Adriana
Costanzo, Sandra
Solimene, Raffaele
author_facet Buonanno, Giovanni
Brancaccio, Adriana
Costanzo, Sandra
Solimene, Raffaele
author_sort Buonanno, Giovanni
collection PubMed
description In this paper, the performance of three recent algorithms for the frequency-response enhancement of microwave resonant sensors are compared. The first one, a single-step algorithm, is based on a couple of direct-inverse Fourier transforms, giving a densely sampled response as a result. The second algorithm exploits an iterative procedure to progressively restricts the frequency response. The final one is based on the super-resolution MUSIC algorithm. The comparison is carried out through a Monte Carlo analysis. In particular, synthetic signals are firstly exploited to mimic the frequency response of a resonant microwave sensor. Then, experimental data collected from water-glucose solutions are adopted as validation test for potential applications in noninvasive blood-glucose monitoring.
format Online
Article
Text
id pubmed-9031377
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90313772022-04-23 Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring Buonanno, Giovanni Brancaccio, Adriana Costanzo, Sandra Solimene, Raffaele Bioengineering (Basel) Article In this paper, the performance of three recent algorithms for the frequency-response enhancement of microwave resonant sensors are compared. The first one, a single-step algorithm, is based on a couple of direct-inverse Fourier transforms, giving a densely sampled response as a result. The second algorithm exploits an iterative procedure to progressively restricts the frequency response. The final one is based on the super-resolution MUSIC algorithm. The comparison is carried out through a Monte Carlo analysis. In particular, synthetic signals are firstly exploited to mimic the frequency response of a resonant microwave sensor. Then, experimental data collected from water-glucose solutions are adopted as validation test for potential applications in noninvasive blood-glucose monitoring. MDPI 2022-04-04 /pmc/articles/PMC9031377/ /pubmed/35447716 http://dx.doi.org/10.3390/bioengineering9040156 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Buonanno, Giovanni
Brancaccio, Adriana
Costanzo, Sandra
Solimene, Raffaele
Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title_full Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title_fullStr Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title_full_unstemmed Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title_short Spectral Methods for Response Enhancement of Microwave Resonant Sensors in Continuous Non-Invasive Blood Glucose Monitoring
title_sort spectral methods for response enhancement of microwave resonant sensors in continuous non-invasive blood glucose monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9031377/
https://www.ncbi.nlm.nih.gov/pubmed/35447716
http://dx.doi.org/10.3390/bioengineering9040156
work_keys_str_mv AT buonannogiovanni spectralmethodsforresponseenhancementofmicrowaveresonantsensorsincontinuousnoninvasivebloodglucosemonitoring
AT brancaccioadriana spectralmethodsforresponseenhancementofmicrowaveresonantsensorsincontinuousnoninvasivebloodglucosemonitoring
AT costanzosandra spectralmethodsforresponseenhancementofmicrowaveresonantsensorsincontinuousnoninvasivebloodglucosemonitoring
AT solimeneraffaele spectralmethodsforresponseenhancementofmicrowaveresonantsensorsincontinuousnoninvasivebloodglucosemonitoring