Cargando…

Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study

Background: We compare the accuracy of new intraoral scanners (IOSs) in full-arch digital implant impressions. Methods: A master model with six scan bodies was milled in poly(methyl methacrylate), measured by using a coordinate measuring machine, and scanned 15 times with four IOSs: PrimeScan, Medit...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Fiore, Adolfo, Graiff, Lorenzo, Savio, Gianpaolo, Granata, Stefano, Basilicata, Michele, Bollero, Patrizio, Meneghello, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9032305/
https://www.ncbi.nlm.nih.gov/pubmed/35457583
http://dx.doi.org/10.3390/ijerph19084719
_version_ 1784692609945436160
author Di Fiore, Adolfo
Graiff, Lorenzo
Savio, Gianpaolo
Granata, Stefano
Basilicata, Michele
Bollero, Patrizio
Meneghello, Roberto
author_facet Di Fiore, Adolfo
Graiff, Lorenzo
Savio, Gianpaolo
Granata, Stefano
Basilicata, Michele
Bollero, Patrizio
Meneghello, Roberto
author_sort Di Fiore, Adolfo
collection PubMed
description Background: We compare the accuracy of new intraoral scanners (IOSs) in full-arch digital implant impressions. Methods: A master model with six scan bodies was milled in poly(methyl methacrylate), measured by using a coordinate measuring machine, and scanned 15 times with four IOSs: PrimeScan, Medit i500, Vatech EZ scan, and iTero. The software was developed to identify the position points on each scan body. The 3D position and distance analysis were performed. Results: The average and ± standard deviation of the 3D position analysis was 29 μm ± 6 μm for PrimeScan, 39 μm ± 6 μm for iTero, 48 μm ± 18 μm for Mediti500, and 118 μm ± 24 μm for Vatech EZ scan (p < 0.05). Conclusions: All IOSs are able to make a digital complete implant impression in vitro according to the average misfit value reported in literature (150 μm); however, the 3D distance analysis showed that only the Primescan and iTero presented negligible systematic error sources.
format Online
Article
Text
id pubmed-9032305
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90323052022-04-23 Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study Di Fiore, Adolfo Graiff, Lorenzo Savio, Gianpaolo Granata, Stefano Basilicata, Michele Bollero, Patrizio Meneghello, Roberto Int J Environ Res Public Health Article Background: We compare the accuracy of new intraoral scanners (IOSs) in full-arch digital implant impressions. Methods: A master model with six scan bodies was milled in poly(methyl methacrylate), measured by using a coordinate measuring machine, and scanned 15 times with four IOSs: PrimeScan, Medit i500, Vatech EZ scan, and iTero. The software was developed to identify the position points on each scan body. The 3D position and distance analysis were performed. Results: The average and ± standard deviation of the 3D position analysis was 29 μm ± 6 μm for PrimeScan, 39 μm ± 6 μm for iTero, 48 μm ± 18 μm for Mediti500, and 118 μm ± 24 μm for Vatech EZ scan (p < 0.05). Conclusions: All IOSs are able to make a digital complete implant impression in vitro according to the average misfit value reported in literature (150 μm); however, the 3D distance analysis showed that only the Primescan and iTero presented negligible systematic error sources. MDPI 2022-04-13 /pmc/articles/PMC9032305/ /pubmed/35457583 http://dx.doi.org/10.3390/ijerph19084719 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Di Fiore, Adolfo
Graiff, Lorenzo
Savio, Gianpaolo
Granata, Stefano
Basilicata, Michele
Bollero, Patrizio
Meneghello, Roberto
Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title_full Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title_fullStr Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title_full_unstemmed Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title_short Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
title_sort investigation of the accuracy of four intraoral scanners in mandibular full-arch digital implant impression: a comparative in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9032305/
https://www.ncbi.nlm.nih.gov/pubmed/35457583
http://dx.doi.org/10.3390/ijerph19084719
work_keys_str_mv AT difioreadolfo investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT graifflorenzo investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT saviogianpaolo investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT granatastefano investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT basilicatamichele investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT bolleropatrizio investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy
AT meneghelloroberto investigationoftheaccuracyoffourintraoralscannersinmandibularfullarchdigitalimplantimpressionacomparativeinvitrostudy