Cargando…
Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series
Whereas in paediatric traumatology for diaphyseal fractures of the radius (intramedullary nail), as well as metaphyseal fractures (K-wire), minimal invasive methods for osteosynthesis were established as gold standard, the ideal osteosynthesis of fractures of the dia-metaphyseal area remains controv...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9032625/ https://www.ncbi.nlm.nih.gov/pubmed/35455623 http://dx.doi.org/10.3390/children9040579 |
_version_ | 1784692690156257280 |
---|---|
author | Krohn, Carsten |
author_facet | Krohn, Carsten |
author_sort | Krohn, Carsten |
collection | PubMed |
description | Whereas in paediatric traumatology for diaphyseal fractures of the radius (intramedullary nail), as well as metaphyseal fractures (K-wire), minimal invasive methods for osteosynthesis were established as gold standard, the ideal osteosynthesis of fractures of the dia-metaphyseal area remains controversial. In this article, the author describes his own minimal invasive technique, using an intramedullary nail that must be pre-bent twice to achieve a stable reduction, with three-point support. The material used for this new surgical technique is an ordinary intramedullary nail. If not available, the operation can also be performed with a sufficiently lengthy K-wire. The intramedullary nail needs to be pre-bent twice, which follows a standardised procedure. A small case series is included to visualise the scope of this minimal-invasive method. |
format | Online Article Text |
id | pubmed-9032625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90326252022-04-23 Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series Krohn, Carsten Children (Basel) Technical Note Whereas in paediatric traumatology for diaphyseal fractures of the radius (intramedullary nail), as well as metaphyseal fractures (K-wire), minimal invasive methods for osteosynthesis were established as gold standard, the ideal osteosynthesis of fractures of the dia-metaphyseal area remains controversial. In this article, the author describes his own minimal invasive technique, using an intramedullary nail that must be pre-bent twice to achieve a stable reduction, with three-point support. The material used for this new surgical technique is an ordinary intramedullary nail. If not available, the operation can also be performed with a sufficiently lengthy K-wire. The intramedullary nail needs to be pre-bent twice, which follows a standardised procedure. A small case series is included to visualise the scope of this minimal-invasive method. MDPI 2022-04-18 /pmc/articles/PMC9032625/ /pubmed/35455623 http://dx.doi.org/10.3390/children9040579 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Krohn, Carsten Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title | Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title_full | Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title_fullStr | Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title_full_unstemmed | Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title_short | Double Pre-Bending of an Intramedullary Nail Is the Minimal Invasive Osteosynthesis Solution for Dia-Metaphyseal Fractures of the Radius in Children: Technical Note and Case Series |
title_sort | double pre-bending of an intramedullary nail is the minimal invasive osteosynthesis solution for dia-metaphyseal fractures of the radius in children: technical note and case series |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9032625/ https://www.ncbi.nlm.nih.gov/pubmed/35455623 http://dx.doi.org/10.3390/children9040579 |
work_keys_str_mv | AT krohncarsten doubleprebendingofanintramedullarynailistheminimalinvasiveosteosynthesissolutionfordiametaphysealfracturesoftheradiusinchildrentechnicalnoteandcaseseries |