Cargando…
Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9033029/ https://www.ncbi.nlm.nih.gov/pubmed/35448722 http://dx.doi.org/10.3390/tomography8020088 |
_version_ | 1784692790567895040 |
---|---|
author | Kimura, Koichiro Fujioka, Tomoyuki Mori, Mio Adachi, Takuya Hiraishi, Takumi Hada, Hiroto Ishikawa, Toshiaki Tateishi, Ukihide |
author_facet | Kimura, Koichiro Fujioka, Tomoyuki Mori, Mio Adachi, Takuya Hiraishi, Takumi Hada, Hiroto Ishikawa, Toshiaki Tateishi, Ukihide |
author_sort | Kimura, Koichiro |
collection | PubMed |
description | Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDI(vol)), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTI(vol) 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9–125.5) mGy·cm vs. 996.7 (886.2–1144.3), p < 0.0001; ED 1.93 (1.73–2.26) mSv vs. 17.9 (16.0–20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs. |
format | Online Article Text |
id | pubmed-9033029 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90330292022-04-23 Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer Kimura, Koichiro Fujioka, Tomoyuki Mori, Mio Adachi, Takuya Hiraishi, Takumi Hada, Hiroto Ishikawa, Toshiaki Tateishi, Ukihide Tomography Article Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDI(vol)), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTI(vol) 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9–125.5) mGy·cm vs. 996.7 (886.2–1144.3), p < 0.0001; ED 1.93 (1.73–2.26) mSv vs. 17.9 (16.0–20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs. MDPI 2022-04-08 /pmc/articles/PMC9033029/ /pubmed/35448722 http://dx.doi.org/10.3390/tomography8020088 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kimura, Koichiro Fujioka, Tomoyuki Mori, Mio Adachi, Takuya Hiraishi, Takumi Hada, Hiroto Ishikawa, Toshiaki Tateishi, Ukihide Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title | Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title_full | Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title_fullStr | Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title_full_unstemmed | Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title_short | Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer |
title_sort | dose reduction and diagnostic performance of tin filter–based spectral shaping ct in patients with colorectal cancer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9033029/ https://www.ncbi.nlm.nih.gov/pubmed/35448722 http://dx.doi.org/10.3390/tomography8020088 |
work_keys_str_mv | AT kimurakoichiro dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT fujiokatomoyuki dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT morimio dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT adachitakuya dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT hiraishitakumi dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT hadahiroto dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT ishikawatoshiaki dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer AT tateishiukihide dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer |