Cargando…

Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer

Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP...

Descripción completa

Detalles Bibliográficos
Autores principales: Kimura, Koichiro, Fujioka, Tomoyuki, Mori, Mio, Adachi, Takuya, Hiraishi, Takumi, Hada, Hiroto, Ishikawa, Toshiaki, Tateishi, Ukihide
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9033029/
https://www.ncbi.nlm.nih.gov/pubmed/35448722
http://dx.doi.org/10.3390/tomography8020088
_version_ 1784692790567895040
author Kimura, Koichiro
Fujioka, Tomoyuki
Mori, Mio
Adachi, Takuya
Hiraishi, Takumi
Hada, Hiroto
Ishikawa, Toshiaki
Tateishi, Ukihide
author_facet Kimura, Koichiro
Fujioka, Tomoyuki
Mori, Mio
Adachi, Takuya
Hiraishi, Takumi
Hada, Hiroto
Ishikawa, Toshiaki
Tateishi, Ukihide
author_sort Kimura, Koichiro
collection PubMed
description Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDI(vol)), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTI(vol) 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9–125.5) mGy·cm vs. 996.7 (886.2–1144.3), p < 0.0001; ED 1.93 (1.73–2.26) mSv vs. 17.9 (16.0–20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs.
format Online
Article
Text
id pubmed-9033029
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90330292022-04-23 Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer Kimura, Koichiro Fujioka, Tomoyuki Mori, Mio Adachi, Takuya Hiraishi, Takumi Hada, Hiroto Ishikawa, Toshiaki Tateishi, Ukihide Tomography Article Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDI(vol)), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTI(vol) 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9–125.5) mGy·cm vs. 996.7 (886.2–1144.3), p < 0.0001; ED 1.93 (1.73–2.26) mSv vs. 17.9 (16.0–20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs. MDPI 2022-04-08 /pmc/articles/PMC9033029/ /pubmed/35448722 http://dx.doi.org/10.3390/tomography8020088 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kimura, Koichiro
Fujioka, Tomoyuki
Mori, Mio
Adachi, Takuya
Hiraishi, Takumi
Hada, Hiroto
Ishikawa, Toshiaki
Tateishi, Ukihide
Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title_full Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title_fullStr Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title_full_unstemmed Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title_short Dose Reduction and Diagnostic Performance of Tin Filter–Based Spectral Shaping CT in Patients with Colorectal Cancer
title_sort dose reduction and diagnostic performance of tin filter–based spectral shaping ct in patients with colorectal cancer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9033029/
https://www.ncbi.nlm.nih.gov/pubmed/35448722
http://dx.doi.org/10.3390/tomography8020088
work_keys_str_mv AT kimurakoichiro dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT fujiokatomoyuki dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT morimio dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT adachitakuya dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT hiraishitakumi dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT hadahiroto dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT ishikawatoshiaki dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer
AT tateishiukihide dosereductionanddiagnosticperformanceoftinfilterbasedspectralshapingctinpatientswithcolorectalcancer