Cargando…
Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate
The concentration of glucose in the body's fluids is an important parameter that can indicate pathological conditions such as the progress of infected wounds. Several wearables and implantable detection approaches have been developed with high selectivity and sensitivity for glucose. However, a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9034389/ https://www.ncbi.nlm.nih.gov/pubmed/35469256 http://dx.doi.org/10.1016/j.mtbio.2022.100258 |
_version_ | 1784693100780716032 |
---|---|
author | Giovannini, Giorgia Cinelli, Paolo Boesel, Luciano F. Rossi, René M. |
author_facet | Giovannini, Giorgia Cinelli, Paolo Boesel, Luciano F. Rossi, René M. |
author_sort | Giovannini, Giorgia |
collection | PubMed |
description | The concentration of glucose in the body's fluids is an important parameter that can indicate pathological conditions such as the progress of infected wounds. Several wearables and implantable detection approaches have been developed with high selectivity and sensitivity for glucose. However, all of them have drawbacks such as low stability, limited selectivity, and often require complex technology. In this work, we present a fluorescent-based cost-efficient imprinted hydrogel (MIH_GSH) capable of detecting glucose within 30 min. The imprinting approach allows us to improve the selectivity for glucose, overcoming the low specificity and limited binding efficiency at neutral pH of boronic acid-based detection mechanisms. The binding affinity determined for glucose-MIH_GSH was indeed 6-fold higher than the one determined for the non-imprinted hydrogel with a calculated imprinting factor of 1.7. The limit of detection of MIH_GSH for glucose in artificial wound exudate was calculated as 0.48 mM at pH 7.4 proving the suitability of the proposed approach to diagnose chronic wounds (ca. 1 mM). MIH_GSH was compared with a commercial colorimetric assay for the quantification of glucose in wound exudate specimens collected from hospitalized patients. The results obtained with the two methods were statistically similar confirming the robustness of our approach. Importantly, whereas with the colorimetric assay sample preparation was required to limit the interference of the sample background, the fluorescent signal of MIH_GSH was not affected even when used to measure glucose directly in bloody samples. The sensing mechanism here proposed can pave the way for the development of cost-efficient and wearable point-of-care tools capable of monitoring the glucose level in wound exudate enabling the quick assessment of chronic injuries. |
format | Online Article Text |
id | pubmed-9034389 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-90343892022-04-24 Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate Giovannini, Giorgia Cinelli, Paolo Boesel, Luciano F. Rossi, René M. Mater Today Bio Full Length Article The concentration of glucose in the body's fluids is an important parameter that can indicate pathological conditions such as the progress of infected wounds. Several wearables and implantable detection approaches have been developed with high selectivity and sensitivity for glucose. However, all of them have drawbacks such as low stability, limited selectivity, and often require complex technology. In this work, we present a fluorescent-based cost-efficient imprinted hydrogel (MIH_GSH) capable of detecting glucose within 30 min. The imprinting approach allows us to improve the selectivity for glucose, overcoming the low specificity and limited binding efficiency at neutral pH of boronic acid-based detection mechanisms. The binding affinity determined for glucose-MIH_GSH was indeed 6-fold higher than the one determined for the non-imprinted hydrogel with a calculated imprinting factor of 1.7. The limit of detection of MIH_GSH for glucose in artificial wound exudate was calculated as 0.48 mM at pH 7.4 proving the suitability of the proposed approach to diagnose chronic wounds (ca. 1 mM). MIH_GSH was compared with a commercial colorimetric assay for the quantification of glucose in wound exudate specimens collected from hospitalized patients. The results obtained with the two methods were statistically similar confirming the robustness of our approach. Importantly, whereas with the colorimetric assay sample preparation was required to limit the interference of the sample background, the fluorescent signal of MIH_GSH was not affected even when used to measure glucose directly in bloody samples. The sensing mechanism here proposed can pave the way for the development of cost-efficient and wearable point-of-care tools capable of monitoring the glucose level in wound exudate enabling the quick assessment of chronic injuries. Elsevier 2022-04-09 /pmc/articles/PMC9034389/ /pubmed/35469256 http://dx.doi.org/10.1016/j.mtbio.2022.100258 Text en © 2022 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Full Length Article Giovannini, Giorgia Cinelli, Paolo Boesel, Luciano F. Rossi, René M. Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title | Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title_full | Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title_fullStr | Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title_full_unstemmed | Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title_short | Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
title_sort | thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate |
topic | Full Length Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9034389/ https://www.ncbi.nlm.nih.gov/pubmed/35469256 http://dx.doi.org/10.1016/j.mtbio.2022.100258 |
work_keys_str_mv | AT giovanninigiorgia thioflavinmodifiedmolecularlyimprintedhydrogelforfluorescentbasednonenzymaticglucosedetectioninwoundexudate AT cinellipaolo thioflavinmodifiedmolecularlyimprintedhydrogelforfluorescentbasednonenzymaticglucosedetectioninwoundexudate AT boesellucianof thioflavinmodifiedmolecularlyimprintedhydrogelforfluorescentbasednonenzymaticglucosedetectioninwoundexudate AT rossirenem thioflavinmodifiedmolecularlyimprintedhydrogelforfluorescentbasednonenzymaticglucosedetectioninwoundexudate |