Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement

PURPOSE: The purpose of this study was to compare concordance between ganglion cell-inner plexiform layer (GCIPL) data from the Cirrus optical coherence tomographer (OCT) Ganglion Cell Analysis (GCA) and visual fields (VFs), with and without Drasdo displacement. METHODS: From 296 open-angle glaucoma...

Descripción completa

Detalles Bibliográficos
Autores principales: Tong, Janelle, Phu, Jack, Alonso-Caneiro, David, Khuu, Sieu K., Kalloniatis, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9034708/
https://www.ncbi.nlm.nih.gov/pubmed/35438719
http://dx.doi.org/10.1167/tvst.11.4.18
_version_ 1784693168431693824
author Tong, Janelle
Phu, Jack
Alonso-Caneiro, David
Khuu, Sieu K.
Kalloniatis, Michael
author_facet Tong, Janelle
Phu, Jack
Alonso-Caneiro, David
Khuu, Sieu K.
Kalloniatis, Michael
author_sort Tong, Janelle
collection PubMed
description PURPOSE: The purpose of this study was to compare concordance between ganglion cell-inner plexiform layer (GCIPL) data from the Cirrus optical coherence tomographer (OCT) Ganglion Cell Analysis (GCA) and visual fields (VFs), with and without Drasdo displacement. METHODS: From 296 open-angle glaucoma participants, GCIPL deviation and raw thickness data were extracted over locations per the 10-2 VF test grid, with and without application of Drasdo displacement, with global and eccentricity-dependent sensitivities and specificities calculated for both. With OCT and VF data classified as within or outside normative limits, pattern deviation values were compared using paired t-tests and Spearman correlations. Regression models were applied to pattern deviation values as a function of GCIPL thickness, and differences in model performance with and without displacement were compared using extra sums-of-squares F tests. RESULTS: There were small but significant improvements in global specificity without displacement (0.58–0.59 with displacement and 0.61 without displacement), without notable differences in sensitivity (0.77–0.78 with displacement and 0.76–0.78 without displacement). At abnormal VF locations and without displacement, a higher proportion of correct OCT classifications (P = 0.0008) and significant correlation with worsening pattern deviation values were observed (r = 0.50, P = 0.002). Regression models indicated significantly steeper slopes with Drasdo displacement centrally (P = 0.002–0.04). CONCLUSIONS: With GCA deviation maps, small improvements in structure-function concordance were observed without displacement, which are unlikely to be clinically meaningful. Using GCIPL thickness data, significantly better structure-function concordance was observed centrally with Drasdo displacement. TRANSLATIONAL RELEVANCE: Applying Drasdo displacement on probability-based reports is unlikely to alter clinical impressions of structure-function concordance, but applying displacement with GCIPL thickness data may improve detection of structure-function concordance.
format Online
Article
Text
id pubmed-9034708
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-90347082022-04-24 Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement Tong, Janelle Phu, Jack Alonso-Caneiro, David Khuu, Sieu K. Kalloniatis, Michael Transl Vis Sci Technol Article PURPOSE: The purpose of this study was to compare concordance between ganglion cell-inner plexiform layer (GCIPL) data from the Cirrus optical coherence tomographer (OCT) Ganglion Cell Analysis (GCA) and visual fields (VFs), with and without Drasdo displacement. METHODS: From 296 open-angle glaucoma participants, GCIPL deviation and raw thickness data were extracted over locations per the 10-2 VF test grid, with and without application of Drasdo displacement, with global and eccentricity-dependent sensitivities and specificities calculated for both. With OCT and VF data classified as within or outside normative limits, pattern deviation values were compared using paired t-tests and Spearman correlations. Regression models were applied to pattern deviation values as a function of GCIPL thickness, and differences in model performance with and without displacement were compared using extra sums-of-squares F tests. RESULTS: There were small but significant improvements in global specificity without displacement (0.58–0.59 with displacement and 0.61 without displacement), without notable differences in sensitivity (0.77–0.78 with displacement and 0.76–0.78 without displacement). At abnormal VF locations and without displacement, a higher proportion of correct OCT classifications (P = 0.0008) and significant correlation with worsening pattern deviation values were observed (r = 0.50, P = 0.002). Regression models indicated significantly steeper slopes with Drasdo displacement centrally (P = 0.002–0.04). CONCLUSIONS: With GCA deviation maps, small improvements in structure-function concordance were observed without displacement, which are unlikely to be clinically meaningful. Using GCIPL thickness data, significantly better structure-function concordance was observed centrally with Drasdo displacement. TRANSLATIONAL RELEVANCE: Applying Drasdo displacement on probability-based reports is unlikely to alter clinical impressions of structure-function concordance, but applying displacement with GCIPL thickness data may improve detection of structure-function concordance. The Association for Research in Vision and Ophthalmology 2022-04-19 /pmc/articles/PMC9034708/ /pubmed/35438719 http://dx.doi.org/10.1167/tvst.11.4.18 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Tong, Janelle
Phu, Jack
Alonso-Caneiro, David
Khuu, Sieu K.
Kalloniatis, Michael
Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title_full Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title_fullStr Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title_full_unstemmed Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title_short Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement
title_sort clinical evaluations of macular structure-function concordance with and without drasdo displacement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9034708/
https://www.ncbi.nlm.nih.gov/pubmed/35438719
http://dx.doi.org/10.1167/tvst.11.4.18
work_keys_str_mv AT tongjanelle clinicalevaluationsofmacularstructurefunctionconcordancewithandwithoutdrasdodisplacement
AT phujack clinicalevaluationsofmacularstructurefunctionconcordancewithandwithoutdrasdodisplacement
AT alonsocaneirodavid clinicalevaluationsofmacularstructurefunctionconcordancewithandwithoutdrasdodisplacement
AT khuusieuk clinicalevaluationsofmacularstructurefunctionconcordancewithandwithoutdrasdodisplacement
AT kalloniatismichael clinicalevaluationsofmacularstructurefunctionconcordancewithandwithoutdrasdodisplacement