Cargando…
Ultrasound-Guided Placement of a Hemodialysis Catheter into the Distal Femoral Vein in a Patient with Multiple Catheters: A Case Report
Cardiac surgery-associated acute kidney injury may require postoperative renal replacement therapy. Although the right internal jugular vein and femoral veins are generally the preferred insertion sites for the hemodialysis catheter for continuous renal replacement therapy, the presence of other ind...
Autores principales: | Morishige, Shuta, Yamaguchi, Yoshikazu, Nakajima, Kei, Tsuboi, Sayaka, Sugawara, Yoh, Hayami, Hajime, Tobias, Joseph D, Inagawa, Gaku |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9034840/ https://www.ncbi.nlm.nih.gov/pubmed/35469269 http://dx.doi.org/10.2147/IMCRJ.S359258 |
Ejemplares similares
-
Anesthetic Care During Tracheostomy in a Patient with Generalized Tetanus: A Case Report
por: Yoshida, Megumi, et al.
Publicado: (2021) -
Migration of guiding catheter during placement of hemodialysis femoral catheter: case report
por: Jabrane, Marouane, et al.
Publicado: (2023) -
Fracture of a femoral hemodialysis catheter during placement in a man with metastatic cancer
por: Li, Xiang‐Yang, et al.
Publicado: (2018) -
Laceration of the Iliac Vein in a Patient with a Femoral Catheter for Hemodialysis
por: Stolic, Radojica V., et al.
Publicado: (2011) -
Placement of Hemodialysis Catheters with a Technical, Functional, and Anatomical Viewpoint
por: Aydin, Zeki, et al.
Publicado: (2012)