Cargando…
Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes
PURPOSE: This study aimed to investigate the influence of intraocular lens (IOL) weight on long-term IOL stability in highly myopic eyes. MATERIALS AND METHODS: A total of 205 highly myopic cataract eyes of 205 patients implanted with the MC X11 ASP (Group A, 86 eyes) or 920H IOL (Group B, 119 eyes)...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9035698/ https://www.ncbi.nlm.nih.gov/pubmed/35479960 http://dx.doi.org/10.3389/fmed.2022.835475 |
_version_ | 1784693353764356096 |
---|---|
author | Chen, Yuxi Meng, Jiaqi Cheng, Kaiwen Lu, Qiang Wei, Ling Lu, Yi Zhu, Xiangjia |
author_facet | Chen, Yuxi Meng, Jiaqi Cheng, Kaiwen Lu, Qiang Wei, Ling Lu, Yi Zhu, Xiangjia |
author_sort | Chen, Yuxi |
collection | PubMed |
description | PURPOSE: This study aimed to investigate the influence of intraocular lens (IOL) weight on long-term IOL stability in highly myopic eyes. MATERIALS AND METHODS: A total of 205 highly myopic cataract eyes of 205 patients implanted with the MC X11 ASP (Group A, 86 eyes) or 920H IOL (Group B, 119 eyes) were included in this retrospective study. Eyes were divided into 3 subgroups according to the IOL power: low (≥-5 to <5 D), medium (≥5 to <14 D), and high (≥14 D) IOL power. At 3 years after surgery, IOL decentration and tilt, high-order aberrations, and anterior capsular opening (ACO) area were measured. The influence of IOL weight on long-term IOL stability was evaluated. RESULTS: Group B had a significantly greater IOL weight than Group A (Group B vs. Group A: 28.31 ± 2.01 mg vs. 25.71 ± 4.62 mg, P < 0.001). Correspondingly, Group B presented significantly greater overall and inferior decentration than Group A, especially for low and medium IOL power (all P < 0.05). In both groups, overall and vertical decentration was significantly correlated with IOL weight (all P < 0.05). Group B showed a significantly greater ACO area than Group A (P < 0.05). Multivariate analysis showed that decentration in Group A was affected by IOL weight, while decentration in Group B was affected by IOL weight and AL. CONCLUSIONS: Higher IOL weight may lead to greater long-term IOL decentration in highly myopic eyes, while the haptic design may play a role in anterior capsular contraction. |
format | Online Article Text |
id | pubmed-9035698 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-90356982022-04-26 Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes Chen, Yuxi Meng, Jiaqi Cheng, Kaiwen Lu, Qiang Wei, Ling Lu, Yi Zhu, Xiangjia Front Med (Lausanne) Medicine PURPOSE: This study aimed to investigate the influence of intraocular lens (IOL) weight on long-term IOL stability in highly myopic eyes. MATERIALS AND METHODS: A total of 205 highly myopic cataract eyes of 205 patients implanted with the MC X11 ASP (Group A, 86 eyes) or 920H IOL (Group B, 119 eyes) were included in this retrospective study. Eyes were divided into 3 subgroups according to the IOL power: low (≥-5 to <5 D), medium (≥5 to <14 D), and high (≥14 D) IOL power. At 3 years after surgery, IOL decentration and tilt, high-order aberrations, and anterior capsular opening (ACO) area were measured. The influence of IOL weight on long-term IOL stability was evaluated. RESULTS: Group B had a significantly greater IOL weight than Group A (Group B vs. Group A: 28.31 ± 2.01 mg vs. 25.71 ± 4.62 mg, P < 0.001). Correspondingly, Group B presented significantly greater overall and inferior decentration than Group A, especially for low and medium IOL power (all P < 0.05). In both groups, overall and vertical decentration was significantly correlated with IOL weight (all P < 0.05). Group B showed a significantly greater ACO area than Group A (P < 0.05). Multivariate analysis showed that decentration in Group A was affected by IOL weight, while decentration in Group B was affected by IOL weight and AL. CONCLUSIONS: Higher IOL weight may lead to greater long-term IOL decentration in highly myopic eyes, while the haptic design may play a role in anterior capsular contraction. Frontiers Media S.A. 2022-04-11 /pmc/articles/PMC9035698/ /pubmed/35479960 http://dx.doi.org/10.3389/fmed.2022.835475 Text en Copyright © 2022 Chen, Meng, Cheng, Lu, Wei, Lu and Zhu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Chen, Yuxi Meng, Jiaqi Cheng, Kaiwen Lu, Qiang Wei, Ling Lu, Yi Zhu, Xiangjia Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title | Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title_full | Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title_fullStr | Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title_full_unstemmed | Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title_short | Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes |
title_sort | influence of iol weight on long-term iol stability in highly myopic eyes |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9035698/ https://www.ncbi.nlm.nih.gov/pubmed/35479960 http://dx.doi.org/10.3389/fmed.2022.835475 |
work_keys_str_mv | AT chenyuxi influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT mengjiaqi influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT chengkaiwen influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT luqiang influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT weiling influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT luyi influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes AT zhuxiangjia influenceofiolweightonlongtermiolstabilityinhighlymyopiceyes |