Cargando…

Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination

A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination. All solid-state ion-selective electrodes (ISEs) for copper and a Ag/AgCl reference electrode were constructed and optimized on the paper substrate. The copper elec...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamel, Ayman H., Amr, Abd El-Galil E., Almehizia, Abdulrahman A., Elsayed, Elsayed A., Moustafa, Gaber O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9037668/
https://www.ncbi.nlm.nih.gov/pubmed/35480650
http://dx.doi.org/10.1039/d1ra04712d
_version_ 1784693767804026880
author Kamel, Ayman H.
Amr, Abd El-Galil E.
Almehizia, Abdulrahman A.
Elsayed, Elsayed A.
Moustafa, Gaber O.
author_facet Kamel, Ayman H.
Amr, Abd El-Galil E.
Almehizia, Abdulrahman A.
Elsayed, Elsayed A.
Moustafa, Gaber O.
author_sort Kamel, Ayman H.
collection PubMed
description A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination. All solid-state ion-selective electrodes (ISEs) for copper and a Ag/AgCl reference electrode were constructed and optimized on the paper substrate. The copper electrodes were built using carbon nano-tube ink as a conductive substrate and an ion-to electron transducer. A suitable polymeric membrane is drop-cast on the surface of the conductive carbon ink window. The copper-sensing membrane is based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for copper detection. Under the optimized conditions, the presented all-solid-state paper-based Cu(2+)-ISEs showed a Nernstian response toward Cu(2+) ions in 30 mM MES buffer, pH 7.0 over the linear range of 5.0 × 10(−7)–1.0 × 10(−3) M with a limit of detection of 8.0 × 10(−8) M. The copper-based sensors exhibited rapid detection of Cu(2+) ions with a short response time (<10 s). The selectivity pattern of these new ionophores towards Cu(2+) ions over many common mono-, di- and trivalent cations was evaluated using the modified separate solution method (MSSM). The presented paper-based analytical device exhibited good intra-day and inter day precision. The presented tool was successfully applied for trace Cu(2+) detection in real samples of serum and whole blood collected from different children with autism spectrum disorder. The data obtained by the proposed potentiometric method were compared with those obtained by the inductively-coupled plasma (ICP) as a reference method. The presented copper paper-based analytical-device can be considered as an attractive tool for point-of-care copper determination because of its affordability, vast availability, and self-pumping ability, particularly when combined with potentiometric detection.
format Online
Article
Text
id pubmed-9037668
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90376682022-04-26 Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination Kamel, Ayman H. Amr, Abd El-Galil E. Almehizia, Abdulrahman A. Elsayed, Elsayed A. Moustafa, Gaber O. RSC Adv Chemistry A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination. All solid-state ion-selective electrodes (ISEs) for copper and a Ag/AgCl reference electrode were constructed and optimized on the paper substrate. The copper electrodes were built using carbon nano-tube ink as a conductive substrate and an ion-to electron transducer. A suitable polymeric membrane is drop-cast on the surface of the conductive carbon ink window. The copper-sensing membrane is based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for copper detection. Under the optimized conditions, the presented all-solid-state paper-based Cu(2+)-ISEs showed a Nernstian response toward Cu(2+) ions in 30 mM MES buffer, pH 7.0 over the linear range of 5.0 × 10(−7)–1.0 × 10(−3) M with a limit of detection of 8.0 × 10(−8) M. The copper-based sensors exhibited rapid detection of Cu(2+) ions with a short response time (<10 s). The selectivity pattern of these new ionophores towards Cu(2+) ions over many common mono-, di- and trivalent cations was evaluated using the modified separate solution method (MSSM). The presented paper-based analytical device exhibited good intra-day and inter day precision. The presented tool was successfully applied for trace Cu(2+) detection in real samples of serum and whole blood collected from different children with autism spectrum disorder. The data obtained by the proposed potentiometric method were compared with those obtained by the inductively-coupled plasma (ICP) as a reference method. The presented copper paper-based analytical-device can be considered as an attractive tool for point-of-care copper determination because of its affordability, vast availability, and self-pumping ability, particularly when combined with potentiometric detection. The Royal Society of Chemistry 2021-08-18 /pmc/articles/PMC9037668/ /pubmed/35480650 http://dx.doi.org/10.1039/d1ra04712d Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Kamel, Ayman H.
Amr, Abd El-Galil E.
Almehizia, Abdulrahman A.
Elsayed, Elsayed A.
Moustafa, Gaber O.
Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title_full Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title_fullStr Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title_full_unstemmed Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title_short Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
title_sort low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9037668/
https://www.ncbi.nlm.nih.gov/pubmed/35480650
http://dx.doi.org/10.1039/d1ra04712d
work_keys_str_mv AT kamelaymanh lowcostpotentiometricpaperbasedanalyticaldevicebasedonnewlysynthesizedmacrocyclicpyridopentapeptidederivativesasnovelionophoresforpointofcarecopperiidetermination
AT amrabdelgalile lowcostpotentiometricpaperbasedanalyticaldevicebasedonnewlysynthesizedmacrocyclicpyridopentapeptidederivativesasnovelionophoresforpointofcarecopperiidetermination
AT almehiziaabdulrahmana lowcostpotentiometricpaperbasedanalyticaldevicebasedonnewlysynthesizedmacrocyclicpyridopentapeptidederivativesasnovelionophoresforpointofcarecopperiidetermination
AT elsayedelsayeda lowcostpotentiometricpaperbasedanalyticaldevicebasedonnewlysynthesizedmacrocyclicpyridopentapeptidederivativesasnovelionophoresforpointofcarecopperiidetermination
AT moustafagabero lowcostpotentiometricpaperbasedanalyticaldevicebasedonnewlysynthesizedmacrocyclicpyridopentapeptidederivativesasnovelionophoresforpointofcarecopperiidetermination