Cargando…

High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T

A novel fluorescence (FL) imaging platform was established for ultrasensitive and rapid detection of cardiac troponin T (cTnT), based on a high-throughput immunosensor chip and a DNA dendrimer capped with a large number of fluorescent dyes (FDD@Cy5). Through an enzyme-free and step-by-step strategy,...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Ruike, Zong, Chen, Li, Gairu, Wang, Junhong, Kong, Tiantian, Li, Fei, Chang, Junmin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9037839/
https://www.ncbi.nlm.nih.gov/pubmed/35480665
http://dx.doi.org/10.1039/d1ra03420k
_version_ 1784693804114116608
author Wang, Ruike
Zong, Chen
Li, Gairu
Wang, Junhong
Kong, Tiantian
Li, Fei
Chang, Junmin
author_facet Wang, Ruike
Zong, Chen
Li, Gairu
Wang, Junhong
Kong, Tiantian
Li, Fei
Chang, Junmin
author_sort Wang, Ruike
collection PubMed
description A novel fluorescence (FL) imaging platform was established for ultrasensitive and rapid detection of cardiac troponin T (cTnT), based on a high-throughput immunosensor chip and a DNA dendrimer capped with a large number of fluorescent dyes (FDD@Cy5). Through an enzyme-free and step-by-step strategy, FDD@Cy5 was self-assembled facilely. After the formation of a sandwich immunocomplex and biotin–streptavidin conjugation, FDD@Cy5 could be captured on the chip. FL signals emerged from Cy5 under external light and the enrichment of Cy5 on the dendrimer led to signal amplification. A FL image containing 90 spots could be collected instantaneously by laser confocal scanning microscopy and the brightness of all the spots corresponded to the concentrations of target cTnT. Under optimal conditions, the immunosensor chip coupled with FDD@Cy5 exhibited an excellent detection limit of 0.10 pg L(−1), a wide linear range from 0.20 pg L(−1) to 2.0 ng L(−1), a sample consumption down to 3.0 μL and a maximum throughput of 45 tests per h. The proposed approach was also applied to cTnT quantitation in serum samples with acceptable accuracy, providing a new avenue for early diagnosis and the prognosis evaluation of acute myocardial infarction.
format Online
Article
Text
id pubmed-9037839
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90378392022-04-26 High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T Wang, Ruike Zong, Chen Li, Gairu Wang, Junhong Kong, Tiantian Li, Fei Chang, Junmin RSC Adv Chemistry A novel fluorescence (FL) imaging platform was established for ultrasensitive and rapid detection of cardiac troponin T (cTnT), based on a high-throughput immunosensor chip and a DNA dendrimer capped with a large number of fluorescent dyes (FDD@Cy5). Through an enzyme-free and step-by-step strategy, FDD@Cy5 was self-assembled facilely. After the formation of a sandwich immunocomplex and biotin–streptavidin conjugation, FDD@Cy5 could be captured on the chip. FL signals emerged from Cy5 under external light and the enrichment of Cy5 on the dendrimer led to signal amplification. A FL image containing 90 spots could be collected instantaneously by laser confocal scanning microscopy and the brightness of all the spots corresponded to the concentrations of target cTnT. Under optimal conditions, the immunosensor chip coupled with FDD@Cy5 exhibited an excellent detection limit of 0.10 pg L(−1), a wide linear range from 0.20 pg L(−1) to 2.0 ng L(−1), a sample consumption down to 3.0 μL and a maximum throughput of 45 tests per h. The proposed approach was also applied to cTnT quantitation in serum samples with acceptable accuracy, providing a new avenue for early diagnosis and the prognosis evaluation of acute myocardial infarction. The Royal Society of Chemistry 2021-08-13 /pmc/articles/PMC9037839/ /pubmed/35480665 http://dx.doi.org/10.1039/d1ra03420k Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Wang, Ruike
Zong, Chen
Li, Gairu
Wang, Junhong
Kong, Tiantian
Li, Fei
Chang, Junmin
High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title_full High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title_fullStr High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title_full_unstemmed High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title_short High-throughput immunosensor chip coupled with a fluorescent DNA dendrimer for ultrasensitive detection of cardiac troponin T
title_sort high-throughput immunosensor chip coupled with a fluorescent dna dendrimer for ultrasensitive detection of cardiac troponin t
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9037839/
https://www.ncbi.nlm.nih.gov/pubmed/35480665
http://dx.doi.org/10.1039/d1ra03420k
work_keys_str_mv AT wangruike highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT zongchen highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT ligairu highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT wangjunhong highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT kongtiantian highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT lifei highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint
AT changjunmin highthroughputimmunosensorchipcoupledwithafluorescentdnadendrimerforultrasensitivedetectionofcardiactroponint