Cargando…

Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial

BACKGROUND: Jcerity Endoscoper Airway is a new back-open endoscopic laryngeal mask airway device with a unique design. Our study sought to compare the implantation, ventilation quality and complications of JEA (Jcerity Endoscoper airway) versus LMA (Laryngeal Mask Airway) Supreme in the procedure of...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Junfei, Li, Lu, Wang, Fang, Lv, Yunqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9040346/
https://www.ncbi.nlm.nih.gov/pubmed/35473459
http://dx.doi.org/10.1186/s12871-022-01666-w
_version_ 1784694316689522688
author Zhou, Junfei
Li, Lu
Wang, Fang
Lv, Yunqi
author_facet Zhou, Junfei
Li, Lu
Wang, Fang
Lv, Yunqi
author_sort Zhou, Junfei
collection PubMed
description BACKGROUND: Jcerity Endoscoper Airway is a new back-open endoscopic laryngeal mask airway device with a unique design. Our study sought to compare the implantation, ventilation quality and complications of JEA (Jcerity Endoscoper airway) versus LMA (Laryngeal Mask Airway) Supreme in the procedure of cerebral aneurysm embolization. METHODS: In this prospective, randomised clinical trial, 182 adult patients with American Society of Anesthesiologists class Ι-II scheduled for interventional embolization of cerebral aneurysms were randomly allocated into the Jcerity Endoscoper airway group and the LMA Supreme group. We compared success rate of LMA implantation, ventilation quality, airway sealing pressure, peak airway pressure, degree of blood staining, postoperative oral hemorrhage, sore throat and other complications between the groups. RESULTS: There were no significant differences between the groups in terms of one-time success rate of LMA implantation, ventilation quality, airway sealing pressure or airway peak pressure. However, LMA Supreme group showed a higher degree of blood staining than the JEA group when the laryngeal mask airway was removed (P = 0.04), and there were also more oral hemorrhages and pharyngeal pain than JEA group (P = 0.03, P = 0.02). No differences were observed between groups in terms of other airway complications related to the LMA. CONCLUSIONS: The JEA could not only achieve comparable one-time success rate of implantation and quality of ventilation as the LMA Supreme, but also have lower blood staining degree of mask and less sore throat in patients undergoing perioperative anticoagulation for cerebral aneurysm interventional embolization. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2100044133; Registered 11/03/2021. Statement: This study adheres to CONSORT guidelines.
format Online
Article
Text
id pubmed-9040346
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-90403462022-04-27 Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial Zhou, Junfei Li, Lu Wang, Fang Lv, Yunqi BMC Anesthesiol Research BACKGROUND: Jcerity Endoscoper Airway is a new back-open endoscopic laryngeal mask airway device with a unique design. Our study sought to compare the implantation, ventilation quality and complications of JEA (Jcerity Endoscoper airway) versus LMA (Laryngeal Mask Airway) Supreme in the procedure of cerebral aneurysm embolization. METHODS: In this prospective, randomised clinical trial, 182 adult patients with American Society of Anesthesiologists class Ι-II scheduled for interventional embolization of cerebral aneurysms were randomly allocated into the Jcerity Endoscoper airway group and the LMA Supreme group. We compared success rate of LMA implantation, ventilation quality, airway sealing pressure, peak airway pressure, degree of blood staining, postoperative oral hemorrhage, sore throat and other complications between the groups. RESULTS: There were no significant differences between the groups in terms of one-time success rate of LMA implantation, ventilation quality, airway sealing pressure or airway peak pressure. However, LMA Supreme group showed a higher degree of blood staining than the JEA group when the laryngeal mask airway was removed (P = 0.04), and there were also more oral hemorrhages and pharyngeal pain than JEA group (P = 0.03, P = 0.02). No differences were observed between groups in terms of other airway complications related to the LMA. CONCLUSIONS: The JEA could not only achieve comparable one-time success rate of implantation and quality of ventilation as the LMA Supreme, but also have lower blood staining degree of mask and less sore throat in patients undergoing perioperative anticoagulation for cerebral aneurysm interventional embolization. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2100044133; Registered 11/03/2021. Statement: This study adheres to CONSORT guidelines. BioMed Central 2022-04-26 /pmc/articles/PMC9040346/ /pubmed/35473459 http://dx.doi.org/10.1186/s12871-022-01666-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zhou, Junfei
Li, Lu
Wang, Fang
Lv, Yunqi
Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title_full Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title_fullStr Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title_full_unstemmed Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title_short Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
title_sort comparison of the jcerity endoscoper airway with the lma supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9040346/
https://www.ncbi.nlm.nih.gov/pubmed/35473459
http://dx.doi.org/10.1186/s12871-022-01666-w
work_keys_str_mv AT zhoujunfei comparisonofthejcerityendoscoperairwaywiththelmasupremeforairwaymanagementinpatientsundergoingcerebralaneurysmembolizationarandomizedcontrollednoninferioritytrial
AT lilu comparisonofthejcerityendoscoperairwaywiththelmasupremeforairwaymanagementinpatientsundergoingcerebralaneurysmembolizationarandomizedcontrollednoninferioritytrial
AT wangfang comparisonofthejcerityendoscoperairwaywiththelmasupremeforairwaymanagementinpatientsundergoingcerebralaneurysmembolizationarandomizedcontrollednoninferioritytrial
AT lvyunqi comparisonofthejcerityendoscoperairwaywiththelmasupremeforairwaymanagementinpatientsundergoingcerebralaneurysmembolizationarandomizedcontrollednoninferioritytrial