Cargando…

Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk

Bat box microclimates vary spatially and temporally in temperature suitability. This heterogeneity subjects roosting bats to a variety of thermoregulatory challenges (e.g. heat and cold stress). Understanding how different bat box designs, landscape placements, weather and bat use affect temperature...

Descripción completa

Detalles Bibliográficos
Autores principales: Crawford, Reed D, Dodd, Luke E, Tillman, Francis E, O’Keefe, Joy M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9041549/
https://www.ncbi.nlm.nih.gov/pubmed/35492416
http://dx.doi.org/10.1093/conphys/coac027
_version_ 1784694549879193600
author Crawford, Reed D
Dodd, Luke E
Tillman, Francis E
O’Keefe, Joy M
author_facet Crawford, Reed D
Dodd, Luke E
Tillman, Francis E
O’Keefe, Joy M
author_sort Crawford, Reed D
collection PubMed
description Bat box microclimates vary spatially and temporally in temperature suitability. This heterogeneity subjects roosting bats to a variety of thermoregulatory challenges (e.g. heat and cold stress). Understanding how different bat box designs, landscape placements, weather and bat use affect temperature suitability and energy expenditure is critical to promote safe and beneficial artificial roosting habitat for species of conservation concern. From April to September 2019, we systematically deployed 480 temperature dataloggers among 40 rocket box style bat boxes of 5 designs and regularly monitored bat abundance. We used bioenergetic models to assess energy costs for endothermic and heterothermic bats and modelled the overheating risk for each box as a function of design, placement, bat abundance and weather. For endothermic bats, predicted daily energy expenditure was lower for solar-exposed placements, large group sizes and a box design with enhanced thermal mass. For heterothermic bats, shaded landscape placements were the most energetically beneficial and bat box design was not important, because all designs generally offered microclimates suitable for torpor use at some position within the box. Overheating risk was highest for solar-exposed landscape placements and for designs lacking modifications to buffer temperature, and with increasing bat abundance, increasing ambient temperature and slower wind speeds. The external water jacket design, with the greatest thermal mass, concomitantly decreased overheating risk and endothermic energy expenditure. By assessing bat box suitability from two physiological perspectives, we provide a robust method to assess the conservation value of bat box design and placement strategies. We recommend future studies examine how changing thermal mass and conductance can be used to diminish overheating risk while also enhancing the effects of social thermoregulation for bat box users.
format Online
Article
Text
id pubmed-9041549
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-90415492022-04-27 Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk Crawford, Reed D Dodd, Luke E Tillman, Francis E O’Keefe, Joy M Conserv Physiol Research Article Bat box microclimates vary spatially and temporally in temperature suitability. This heterogeneity subjects roosting bats to a variety of thermoregulatory challenges (e.g. heat and cold stress). Understanding how different bat box designs, landscape placements, weather and bat use affect temperature suitability and energy expenditure is critical to promote safe and beneficial artificial roosting habitat for species of conservation concern. From April to September 2019, we systematically deployed 480 temperature dataloggers among 40 rocket box style bat boxes of 5 designs and regularly monitored bat abundance. We used bioenergetic models to assess energy costs for endothermic and heterothermic bats and modelled the overheating risk for each box as a function of design, placement, bat abundance and weather. For endothermic bats, predicted daily energy expenditure was lower for solar-exposed placements, large group sizes and a box design with enhanced thermal mass. For heterothermic bats, shaded landscape placements were the most energetically beneficial and bat box design was not important, because all designs generally offered microclimates suitable for torpor use at some position within the box. Overheating risk was highest for solar-exposed landscape placements and for designs lacking modifications to buffer temperature, and with increasing bat abundance, increasing ambient temperature and slower wind speeds. The external water jacket design, with the greatest thermal mass, concomitantly decreased overheating risk and endothermic energy expenditure. By assessing bat box suitability from two physiological perspectives, we provide a robust method to assess the conservation value of bat box design and placement strategies. We recommend future studies examine how changing thermal mass and conductance can be used to diminish overheating risk while also enhancing the effects of social thermoregulation for bat box users. Oxford University Press 2022-04-25 /pmc/articles/PMC9041549/ /pubmed/35492416 http://dx.doi.org/10.1093/conphys/coac027 Text en © The Author(s) 2022. Published by Oxford University Press and the Society for Experimental Biology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Crawford, Reed D
Dodd, Luke E
Tillman, Francis E
O’Keefe, Joy M
Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title_full Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title_fullStr Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title_full_unstemmed Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title_short Evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
title_sort evaluating bat boxes: design and placement alter bioenergetic costs and overheating risk
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9041549/
https://www.ncbi.nlm.nih.gov/pubmed/35492416
http://dx.doi.org/10.1093/conphys/coac027
work_keys_str_mv AT crawfordreedd evaluatingbatboxesdesignandplacementalterbioenergeticcostsandoverheatingrisk
AT doddlukee evaluatingbatboxesdesignandplacementalterbioenergeticcostsandoverheatingrisk
AT tillmanfrancise evaluatingbatboxesdesignandplacementalterbioenergeticcostsandoverheatingrisk
AT okeefejoym evaluatingbatboxesdesignandplacementalterbioenergeticcostsandoverheatingrisk