Cargando…
Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor
In this work, a sensitive and efficient voltammetric biosensor was introduced for differential pulse voltammetric (DPV) determination of some phthalic acid esters (PAEs) including dibutyl phthalate (DBP), dimethyl phthalate (DMP), di(2-ethylhexyl)phthalate (DEHP) and dicyclohexyl phthalate (DCHP) in...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042225/ https://www.ncbi.nlm.nih.gov/pubmed/35493596 http://dx.doi.org/10.1039/d1ra04714k |
_version_ | 1784694616265588736 |
---|---|
author | Darvishi, Maryam Shariati, Shahab Safa, Fariba Islamnezhad, Akbar |
author_facet | Darvishi, Maryam Shariati, Shahab Safa, Fariba Islamnezhad, Akbar |
author_sort | Darvishi, Maryam |
collection | PubMed |
description | In this work, a sensitive and efficient voltammetric biosensor was introduced for differential pulse voltammetric (DPV) determination of some phthalic acid esters (PAEs) including dibutyl phthalate (DBP), dimethyl phthalate (DMP), di(2-ethylhexyl)phthalate (DEHP) and dicyclohexyl phthalate (DCHP) in aqueous solutions. Briefly, the surface of a copper electrode was modified by azolla paste prepared using azolla powder and electroencephalography gel (EEG). The modified surface was characterized by electrochemical impedance spectroscopy (EIS), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), Brunauer–Emmett–Teller (BET) analysis and energy dispersive X-ray (EDX) methods. Determination of PAEs was conducted based on their blocking effect on the electrode surface for ferrous ion oxidation. The central composite design (CCD) was conducted to optimize the effects of four experimental parameters including the concentration of Fe(2+) ions (C(Fe(2+))) and supporting electrolyte (C(sup. elec)), solution pH and modifier/gel mass ratio on the decrease in the anodic peak current of ferrous ions as the response. Predicted optimal conditions (C(Fe(2+))= 319 μM, C(sup. elec)= 0.125 M, pH = 7.52 and modifier/gel mass ratio = 0.19) were validated by experimental checking which resulted in an error of 1.453%. At the optimum conditions, linear relationships were found between the DPV responses and PAEs concentrations and the limit of detection (LOD) and limit of quantification (LOQ) values were in the ranges of 0.2–0.4 μg L(−1) and 0.5–1.0 μg L(−1), respectively. Good recovery percentages ranging from 97.3 to 100.3% with RSD < 3.2% suggested the proposed method for efficient, accurate and quick determination of PAEs in real water samples. |
format | Online Article Text |
id | pubmed-9042225 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-90422252022-04-28 Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor Darvishi, Maryam Shariati, Shahab Safa, Fariba Islamnezhad, Akbar RSC Adv Chemistry In this work, a sensitive and efficient voltammetric biosensor was introduced for differential pulse voltammetric (DPV) determination of some phthalic acid esters (PAEs) including dibutyl phthalate (DBP), dimethyl phthalate (DMP), di(2-ethylhexyl)phthalate (DEHP) and dicyclohexyl phthalate (DCHP) in aqueous solutions. Briefly, the surface of a copper electrode was modified by azolla paste prepared using azolla powder and electroencephalography gel (EEG). The modified surface was characterized by electrochemical impedance spectroscopy (EIS), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), Brunauer–Emmett–Teller (BET) analysis and energy dispersive X-ray (EDX) methods. Determination of PAEs was conducted based on their blocking effect on the electrode surface for ferrous ion oxidation. The central composite design (CCD) was conducted to optimize the effects of four experimental parameters including the concentration of Fe(2+) ions (C(Fe(2+))) and supporting electrolyte (C(sup. elec)), solution pH and modifier/gel mass ratio on the decrease in the anodic peak current of ferrous ions as the response. Predicted optimal conditions (C(Fe(2+))= 319 μM, C(sup. elec)= 0.125 M, pH = 7.52 and modifier/gel mass ratio = 0.19) were validated by experimental checking which resulted in an error of 1.453%. At the optimum conditions, linear relationships were found between the DPV responses and PAEs concentrations and the limit of detection (LOD) and limit of quantification (LOQ) values were in the ranges of 0.2–0.4 μg L(−1) and 0.5–1.0 μg L(−1), respectively. Good recovery percentages ranging from 97.3 to 100.3% with RSD < 3.2% suggested the proposed method for efficient, accurate and quick determination of PAEs in real water samples. The Royal Society of Chemistry 2021-10-05 /pmc/articles/PMC9042225/ /pubmed/35493596 http://dx.doi.org/10.1039/d1ra04714k Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Darvishi, Maryam Shariati, Shahab Safa, Fariba Islamnezhad, Akbar Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title | Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title_full | Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title_fullStr | Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title_full_unstemmed | Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title_short | Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
title_sort | surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042225/ https://www.ncbi.nlm.nih.gov/pubmed/35493596 http://dx.doi.org/10.1039/d1ra04714k |
work_keys_str_mv | AT darvishimaryam surfaceblockingofazollamodifiedcopperelectrodefortracedeterminationofphthalicacidestersasthemolecularbarricadesbydifferentialpulsevoltammetryresponsesurfacemodellingoptimizedbiosensor AT shariatishahab surfaceblockingofazollamodifiedcopperelectrodefortracedeterminationofphthalicacidestersasthemolecularbarricadesbydifferentialpulsevoltammetryresponsesurfacemodellingoptimizedbiosensor AT safafariba surfaceblockingofazollamodifiedcopperelectrodefortracedeterminationofphthalicacidestersasthemolecularbarricadesbydifferentialpulsevoltammetryresponsesurfacemodellingoptimizedbiosensor AT islamnezhadakbar surfaceblockingofazollamodifiedcopperelectrodefortracedeterminationofphthalicacidestersasthemolecularbarricadesbydifferentialpulsevoltammetryresponsesurfacemodellingoptimizedbiosensor |