Cargando…

Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape

PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface o...

Descripción completa

Detalles Bibliográficos
Autores principales: Sasaki, Shizuka, Yamauchi, Shohei, Sasaki, Eiji, Kimura, Yuka, Takahashi, Akane, Ishibashi, Yasuyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042741/
https://www.ncbi.nlm.nih.gov/pubmed/35494288
http://dx.doi.org/10.1016/j.asmr.2021.08.019
_version_ 1784694727459733504
author Sasaki, Shizuka
Yamauchi, Shohei
Sasaki, Eiji
Kimura, Yuka
Takahashi, Akane
Ishibashi, Yasuyuki
author_facet Sasaki, Shizuka
Yamauchi, Shohei
Sasaki, Eiji
Kimura, Yuka
Takahashi, Akane
Ishibashi, Yasuyuki
author_sort Sasaki, Shizuka
collection PubMed
description PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface of the medial femoral condyle to achieve a thickness of 5 mm, was used to mimic the unstable osteochondral fragment. It was fixed using three techniques, including two osteochondral plugs (osteochondral plug group), four full-threaded poly l-lactic acid pins (bioabsorbable pin group), and three suture anchors with a 2-0 tape (suture anchor group). Tensile loads at displacements of 1 and 2 mm and ultimate failure load were measured at a cross-head speed of 100 mm/min, and the variables of the three groups were compared statistically using a one-way ANOVA with Tukey’s honestly significant difference test. RESULTS: There was no significant difference in the tensile load to achieve 1-mm displacement. The load to achieve 2-mm displacement and the ultimate failure load were significantly greater in the suture anchor group than the osteochondral plug group and the bioabsorbable pin group. CONCLUSIONS: Single-pull destructive testing of a fixed articular osteochondral fragment with the force perpendicular to the articular surface, demonstrated no statistical difference in the tensile load to achieve 1-mm displacement, but the load to achieve 2-mm displacement was significantly greater for the three suture anchor-interlocking 2-0 tape constructs than the dual osteochondral plug fixation and the four bioabsorbable pin fixation constructs. Additionally, the three suture anchor-interlocking 2-0 tape construct’s mean single-pull failure load was greater than other two fixation procedures. CLINICAL RELEVANCE: To achieve osteochondral fragment union, sufficient fixation strength is critical. However, the initial fixation strength of osteochondral plugs, bioabsorbable pins, and knotless suture anchors for unstable osteochondral lesions remains unclear.
format Online
Article
Text
id pubmed-9042741
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-90427412022-04-28 Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape Sasaki, Shizuka Yamauchi, Shohei Sasaki, Eiji Kimura, Yuka Takahashi, Akane Ishibashi, Yasuyuki Arthrosc Sports Med Rehabil Original Article PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface of the medial femoral condyle to achieve a thickness of 5 mm, was used to mimic the unstable osteochondral fragment. It was fixed using three techniques, including two osteochondral plugs (osteochondral plug group), four full-threaded poly l-lactic acid pins (bioabsorbable pin group), and three suture anchors with a 2-0 tape (suture anchor group). Tensile loads at displacements of 1 and 2 mm and ultimate failure load were measured at a cross-head speed of 100 mm/min, and the variables of the three groups were compared statistically using a one-way ANOVA with Tukey’s honestly significant difference test. RESULTS: There was no significant difference in the tensile load to achieve 1-mm displacement. The load to achieve 2-mm displacement and the ultimate failure load were significantly greater in the suture anchor group than the osteochondral plug group and the bioabsorbable pin group. CONCLUSIONS: Single-pull destructive testing of a fixed articular osteochondral fragment with the force perpendicular to the articular surface, demonstrated no statistical difference in the tensile load to achieve 1-mm displacement, but the load to achieve 2-mm displacement was significantly greater for the three suture anchor-interlocking 2-0 tape constructs than the dual osteochondral plug fixation and the four bioabsorbable pin fixation constructs. Additionally, the three suture anchor-interlocking 2-0 tape construct’s mean single-pull failure load was greater than other two fixation procedures. CLINICAL RELEVANCE: To achieve osteochondral fragment union, sufficient fixation strength is critical. However, the initial fixation strength of osteochondral plugs, bioabsorbable pins, and knotless suture anchors for unstable osteochondral lesions remains unclear. Elsevier 2022-02-01 /pmc/articles/PMC9042741/ /pubmed/35494288 http://dx.doi.org/10.1016/j.asmr.2021.08.019 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Sasaki, Shizuka
Yamauchi, Shohei
Sasaki, Eiji
Kimura, Yuka
Takahashi, Akane
Ishibashi, Yasuyuki
Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title_full Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title_fullStr Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title_full_unstemmed Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title_short Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
title_sort biomechanical analysis of unstable osteochondral fragment fixation using three different techniques: osteochondral plug, bioabsorbable pin, and suture anchor with tape
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042741/
https://www.ncbi.nlm.nih.gov/pubmed/35494288
http://dx.doi.org/10.1016/j.asmr.2021.08.019
work_keys_str_mv AT sasakishizuka biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape
AT yamauchishohei biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape
AT sasakieiji biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape
AT kimurayuka biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape
AT takahashiakane biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape
AT ishibashiyasuyuki biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape