Cargando…
Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape
PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042741/ https://www.ncbi.nlm.nih.gov/pubmed/35494288 http://dx.doi.org/10.1016/j.asmr.2021.08.019 |
_version_ | 1784694727459733504 |
---|---|
author | Sasaki, Shizuka Yamauchi, Shohei Sasaki, Eiji Kimura, Yuka Takahashi, Akane Ishibashi, Yasuyuki |
author_facet | Sasaki, Shizuka Yamauchi, Shohei Sasaki, Eiji Kimura, Yuka Takahashi, Akane Ishibashi, Yasuyuki |
author_sort | Sasaki, Shizuka |
collection | PubMed |
description | PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface of the medial femoral condyle to achieve a thickness of 5 mm, was used to mimic the unstable osteochondral fragment. It was fixed using three techniques, including two osteochondral plugs (osteochondral plug group), four full-threaded poly l-lactic acid pins (bioabsorbable pin group), and three suture anchors with a 2-0 tape (suture anchor group). Tensile loads at displacements of 1 and 2 mm and ultimate failure load were measured at a cross-head speed of 100 mm/min, and the variables of the three groups were compared statistically using a one-way ANOVA with Tukey’s honestly significant difference test. RESULTS: There was no significant difference in the tensile load to achieve 1-mm displacement. The load to achieve 2-mm displacement and the ultimate failure load were significantly greater in the suture anchor group than the osteochondral plug group and the bioabsorbable pin group. CONCLUSIONS: Single-pull destructive testing of a fixed articular osteochondral fragment with the force perpendicular to the articular surface, demonstrated no statistical difference in the tensile load to achieve 1-mm displacement, but the load to achieve 2-mm displacement was significantly greater for the three suture anchor-interlocking 2-0 tape constructs than the dual osteochondral plug fixation and the four bioabsorbable pin fixation constructs. Additionally, the three suture anchor-interlocking 2-0 tape construct’s mean single-pull failure load was greater than other two fixation procedures. CLINICAL RELEVANCE: To achieve osteochondral fragment union, sufficient fixation strength is critical. However, the initial fixation strength of osteochondral plugs, bioabsorbable pins, and knotless suture anchors for unstable osteochondral lesions remains unclear. |
format | Online Article Text |
id | pubmed-9042741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-90427412022-04-28 Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape Sasaki, Shizuka Yamauchi, Shohei Sasaki, Eiji Kimura, Yuka Takahashi, Akane Ishibashi, Yasuyuki Arthrosc Sports Med Rehabil Original Article PURPOSE: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors. METHODS: Eighteen fresh-frozen immature (6 month old) porcine knees were used. An osteochondral fragment, cut from the articular surface of the medial femoral condyle to achieve a thickness of 5 mm, was used to mimic the unstable osteochondral fragment. It was fixed using three techniques, including two osteochondral plugs (osteochondral plug group), four full-threaded poly l-lactic acid pins (bioabsorbable pin group), and three suture anchors with a 2-0 tape (suture anchor group). Tensile loads at displacements of 1 and 2 mm and ultimate failure load were measured at a cross-head speed of 100 mm/min, and the variables of the three groups were compared statistically using a one-way ANOVA with Tukey’s honestly significant difference test. RESULTS: There was no significant difference in the tensile load to achieve 1-mm displacement. The load to achieve 2-mm displacement and the ultimate failure load were significantly greater in the suture anchor group than the osteochondral plug group and the bioabsorbable pin group. CONCLUSIONS: Single-pull destructive testing of a fixed articular osteochondral fragment with the force perpendicular to the articular surface, demonstrated no statistical difference in the tensile load to achieve 1-mm displacement, but the load to achieve 2-mm displacement was significantly greater for the three suture anchor-interlocking 2-0 tape constructs than the dual osteochondral plug fixation and the four bioabsorbable pin fixation constructs. Additionally, the three suture anchor-interlocking 2-0 tape construct’s mean single-pull failure load was greater than other two fixation procedures. CLINICAL RELEVANCE: To achieve osteochondral fragment union, sufficient fixation strength is critical. However, the initial fixation strength of osteochondral plugs, bioabsorbable pins, and knotless suture anchors for unstable osteochondral lesions remains unclear. Elsevier 2022-02-01 /pmc/articles/PMC9042741/ /pubmed/35494288 http://dx.doi.org/10.1016/j.asmr.2021.08.019 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Sasaki, Shizuka Yamauchi, Shohei Sasaki, Eiji Kimura, Yuka Takahashi, Akane Ishibashi, Yasuyuki Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title | Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title_full | Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title_fullStr | Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title_full_unstemmed | Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title_short | Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape |
title_sort | biomechanical analysis of unstable osteochondral fragment fixation using three different techniques: osteochondral plug, bioabsorbable pin, and suture anchor with tape |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042741/ https://www.ncbi.nlm.nih.gov/pubmed/35494288 http://dx.doi.org/10.1016/j.asmr.2021.08.019 |
work_keys_str_mv | AT sasakishizuka biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape AT yamauchishohei biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape AT sasakieiji biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape AT kimurayuka biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape AT takahashiakane biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape AT ishibashiyasuyuki biomechanicalanalysisofunstableosteochondralfragmentfixationusingthreedifferenttechniquesosteochondralplugbioabsorbablepinandsutureanchorwithtape |