Cargando…

Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor

Growing concerns about the possible toxicity of silver to aquatic organisms, bacteria, and humans have led to newly issued regulations by the United States Environmental Protection Agency (US EPA) and the Food and Drug Administration (FDA) regarding the use of silver. However, the increase in bacter...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Feky, Hesham H., Askar, Abdelrazek M., Amin, Alaa S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042815/
https://www.ncbi.nlm.nih.gov/pubmed/35493157
http://dx.doi.org/10.1039/d1ra06660a
_version_ 1784694748974415872
author El-Feky, Hesham H.
Askar, Abdelrazek M.
Amin, Alaa S.
author_facet El-Feky, Hesham H.
Askar, Abdelrazek M.
Amin, Alaa S.
author_sort El-Feky, Hesham H.
collection PubMed
description Growing concerns about the possible toxicity of silver to aquatic organisms, bacteria, and humans have led to newly issued regulations by the United States Environmental Protection Agency (US EPA) and the Food and Drug Administration (FDA) regarding the use of silver. However, the increase in bacterial resistance to antibiotics has led to a resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). For Ag(+) ion detection, a highly sensitive and reversible optical sensor has been established. The optode relies on a novel Schiff base, namely 2-[(benzo[d]thiazol-2-ylimino)methyl]phenol (BTMP) immobilized within PVC film and also incorporated with tris(2-ethylhexyl)phosphate (TEHP) and Aliquat 336 as an ion carrier. Under optimum conditions (i.e. pH 8.5), the proposed sensor displayed a linear response to Ag(+) over 4.8 × 10(−9) to 1.0 × 10(−5) M (0.8494–1698.7 μg L(−1)) with limits of detection and quantification of 1.5 × 10(−9) and 4.8 × 10(−9) M (0.2548 and 0.8494 μg L(−1)), respectively. The sensor's response time was found to be 8.0 min. The sensor was applied successfully to determine Ag(+) ion in some real samples, including food, biological, water, and environmental samples.
format Online
Article
Text
id pubmed-9042815
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90428152022-04-28 Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor El-Feky, Hesham H. Askar, Abdelrazek M. Amin, Alaa S. RSC Adv Chemistry Growing concerns about the possible toxicity of silver to aquatic organisms, bacteria, and humans have led to newly issued regulations by the United States Environmental Protection Agency (US EPA) and the Food and Drug Administration (FDA) regarding the use of silver. However, the increase in bacterial resistance to antibiotics has led to a resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). For Ag(+) ion detection, a highly sensitive and reversible optical sensor has been established. The optode relies on a novel Schiff base, namely 2-[(benzo[d]thiazol-2-ylimino)methyl]phenol (BTMP) immobilized within PVC film and also incorporated with tris(2-ethylhexyl)phosphate (TEHP) and Aliquat 336 as an ion carrier. Under optimum conditions (i.e. pH 8.5), the proposed sensor displayed a linear response to Ag(+) over 4.8 × 10(−9) to 1.0 × 10(−5) M (0.8494–1698.7 μg L(−1)) with limits of detection and quantification of 1.5 × 10(−9) and 4.8 × 10(−9) M (0.2548 and 0.8494 μg L(−1)), respectively. The sensor's response time was found to be 8.0 min. The sensor was applied successfully to determine Ag(+) ion in some real samples, including food, biological, water, and environmental samples. The Royal Society of Chemistry 2021-11-01 /pmc/articles/PMC9042815/ /pubmed/35493157 http://dx.doi.org/10.1039/d1ra06660a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
El-Feky, Hesham H.
Askar, Abdelrazek M.
Amin, Alaa S.
Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title_full Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title_fullStr Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title_full_unstemmed Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title_short Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
title_sort quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9042815/
https://www.ncbi.nlm.nih.gov/pubmed/35493157
http://dx.doi.org/10.1039/d1ra06660a
work_keys_str_mv AT elfekyheshamh quantificationofsilverinseveralsamplesusinganewionophorepolymermembraneasanopticalsensor
AT askarabdelrazekm quantificationofsilverinseveralsamplesusinganewionophorepolymermembraneasanopticalsensor
AT aminalaas quantificationofsilverinseveralsamplesusinganewionophorepolymermembraneasanopticalsensor