Cargando…

Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation

BACKGROUND: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural...

Descripción completa

Detalles Bibliográficos
Autores principales: van Deutekom, C., Mulder, B. A., Groenveld, H. F., Tieleman, R. G., Wiesfeld, A. C. P., Tan, E. S., van Gelder, I. C., Rienstra, M., Blaauw, Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043054/
https://www.ncbi.nlm.nih.gov/pubmed/34762282
http://dx.doi.org/10.1007/s12471-021-01645-9
Descripción
Sumario:BACKGROUND: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI. METHODS: We included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase ≥ 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response. RESULTS: Following PVI, mean HR ± standard deviation increased in the entire group from 63.5 ± 8.4 to 69.1 ± 9.9 bpm at 3 months (p < 0.001), and to 71.9 ± 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 ± 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 ± 10.6 bpm (pre-ablation), 84.6 ± 9.8 bpm (3 months), 80.1 ± 6.5 bpm (6 months) and 76.3 ± 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation. CONCLUSION: Few patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year.