Cargando…

Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation

BACKGROUND: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural...

Descripción completa

Detalles Bibliográficos
Autores principales: van Deutekom, C., Mulder, B. A., Groenveld, H. F., Tieleman, R. G., Wiesfeld, A. C. P., Tan, E. S., van Gelder, I. C., Rienstra, M., Blaauw, Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043054/
https://www.ncbi.nlm.nih.gov/pubmed/34762282
http://dx.doi.org/10.1007/s12471-021-01645-9
_version_ 1784694799776874496
author van Deutekom, C.
Mulder, B. A.
Groenveld, H. F.
Tieleman, R. G.
Wiesfeld, A. C. P.
Tan, E. S.
van Gelder, I. C.
Rienstra, M.
Blaauw, Y.
author_facet van Deutekom, C.
Mulder, B. A.
Groenveld, H. F.
Tieleman, R. G.
Wiesfeld, A. C. P.
Tan, E. S.
van Gelder, I. C.
Rienstra, M.
Blaauw, Y.
author_sort van Deutekom, C.
collection PubMed
description BACKGROUND: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI. METHODS: We included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase ≥ 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response. RESULTS: Following PVI, mean HR ± standard deviation increased in the entire group from 63.5 ± 8.4 to 69.1 ± 9.9 bpm at 3 months (p < 0.001), and to 71.9 ± 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 ± 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 ± 10.6 bpm (pre-ablation), 84.6 ± 9.8 bpm (3 months), 80.1 ± 6.5 bpm (6 months) and 76.3 ± 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation. CONCLUSION: Few patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year.
format Online
Article
Text
id pubmed-9043054
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-90430542022-05-07 Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation van Deutekom, C. Mulder, B. A. Groenveld, H. F. Tieleman, R. G. Wiesfeld, A. C. P. Tan, E. S. van Gelder, I. C. Rienstra, M. Blaauw, Y. Neth Heart J Original Article BACKGROUND: Cryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI. METHODS: We included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase ≥ 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response. RESULTS: Following PVI, mean HR ± standard deviation increased in the entire group from 63.5 ± 8.4 to 69.1 ± 9.9 bpm at 3 months (p < 0.001), and to 71.9 ± 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 ± 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 ± 10.6 bpm (pre-ablation), 84.6 ± 9.8 bpm (3 months), 80.1 ± 6.5 bpm (6 months) and 76.3 ± 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation. CONCLUSION: Few patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year. Bohn Stafleu van Loghum 2021-11-11 2022-05 /pmc/articles/PMC9043054/ /pubmed/34762282 http://dx.doi.org/10.1007/s12471-021-01645-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
van Deutekom, C.
Mulder, B. A.
Groenveld, H. F.
Tieleman, R. G.
Wiesfeld, A. C. P.
Tan, E. S.
van Gelder, I. C.
Rienstra, M.
Blaauw, Y.
Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title_full Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title_fullStr Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title_full_unstemmed Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title_short Heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
title_sort heart rate increase and inappropriate sinus tachycardia after cryoballoon pulmonary vein isolation for atrial fibrillation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043054/
https://www.ncbi.nlm.nih.gov/pubmed/34762282
http://dx.doi.org/10.1007/s12471-021-01645-9
work_keys_str_mv AT vandeutekomc heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT mulderba heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT groenveldhf heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT tielemanrg heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT wiesfeldacp heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT tanes heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT vangelderic heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT rienstram heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation
AT blaauwy heartrateincreaseandinappropriatesinustachycardiaaftercryoballoonpulmonaryveinisolationforatrialfibrillation