Non-Invasive Monitoring of Core Body Temperature for Targeted Temperature Management in Post-Cardiac Arrest Care

IMPORTANCE: Accurate monitoring of core body temperature is integral to targeted temperature management (TTM) following cardiac arrest. However, there are no reliable non-invasive methods for monitoring temperature during TTM. OBJECTIVES: We compared the accuracy and precision of a novel non-invasiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Fiorini, Kyle, Tamasi, Tanya, Dorie, Justin, Hegazy, Ahmed F., Lee, Ting-Yim, Slessarev, Marat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043456/
https://www.ncbi.nlm.nih.gov/pubmed/35492302
http://dx.doi.org/10.3389/fmed.2022.810825
Descripción
Sumario:IMPORTANCE: Accurate monitoring of core body temperature is integral to targeted temperature management (TTM) following cardiac arrest. However, there are no reliable non-invasive methods for monitoring temperature during TTM. OBJECTIVES: We compared the accuracy and precision of a novel non-invasive Zero-Heat-Flux Thermometer (SpotOn™) to a standard invasive esophageal probe in a cohort of patients undergoing TTM post-cardiac arrest. DESIGN, SETTING, AND PARTICIPANTS: We prospectively enrolled 20 patients undergoing post-cardiac arrest care in the intensive care units at the London Health Sciences Centre in London, Canada. A SpotOn™ probe was applied on each patient's forehead, while an esophageal temperature probe was inserted, and both temperature readings were recorded at 1-min intervals for the duration of TTM. MAIN OUTCOMES AND MEASURES: We compared the SpotOn™ and esophageal monitors using the Bland–Altman analysis and the Pearson correlation, with accuracy set as a primary outcome. Secondary outcomes included precision and correlation. Bias exceeding 0.1°C and limits of agreement exceeding 0.5°C were considered clinically important. RESULTS: Sixteen (80%) of patients had complete data used in the final analysis. The median (interquartile range) duration of recording was 38 (12–56) h. Compared to the esophageal probe, SpotOn™ had a bias of 0.06 ± 0.45°C and 95% limits of agreement of −0.83 to 0.95°C. The Pearson correlation coefficient was 0.97 (95% confidence interval 0.9663–0.9678), with a two-tailed p < 0.0001. CONCLUSION AND RELEVANCE: The SpotOn™ is an accurate method that may enable non-invasive monitoring of core body temperature during TTM, although its precision is slightly worse than the predefined 0.5°C when compared to invasive esophageal probe.