Cargando…
Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements
Purpose: The Ocular Response Analyzer (ORA) is one of the most commonly used devices to measure corneal biomechanics in vivo. Until now, the relationship between the output parameters and corneal typical biomechanical parameters was not clear. Hence, we defined the output parameters of ORA as ORA ou...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043460/ https://www.ncbi.nlm.nih.gov/pubmed/35497338 http://dx.doi.org/10.3389/fbioe.2022.862947 |
_version_ | 1784694884958994432 |
---|---|
author | Qin, Xiao Tian, Lei Zhang, Hui Zhang, Di Jie, Ying Zhang, Hai-Xia Li, Lin |
author_facet | Qin, Xiao Tian, Lei Zhang, Hui Zhang, Di Jie, Ying Zhang, Hai-Xia Li, Lin |
author_sort | Qin, Xiao |
collection | PubMed |
description | Purpose: The Ocular Response Analyzer (ORA) is one of the most commonly used devices to measure corneal biomechanics in vivo. Until now, the relationship between the output parameters and corneal typical biomechanical parameters was not clear. Hence, we defined the output parameters of ORA as ORA output parameters. This study aims to propose a method to determine corneal biomechanical parameters based on ORA measurements by finite element simulation and parametric analysis. Methods: Finite element analysis was used to simulate the mechanics process of ORA measurements with different intraocular pressure (IOP), corneal geometrical parameters and corneal biomechanical parameters. A simplified geometrical optics model was built to simulate the optical process of the measurements to extract ORA output parameters. After that, 70% of the simulated data was used to establish the quantitative relationship between corneal biomechanical parameters and ORA output parameters by parametric analysis and 30% of the simulated data was used to validate the established model. Besides, ten normal subjects were included to evaluate the normal range of corneal biomechanical parameters calculated from ORA. Results: The quantitative relationship between corneal biomechanical parameters and ORA output parameters is established by combining parametric analysis with finite element simulation. The elastic modulus (E) and relaxation limit (G (∞)) of the ten normal subjects were 0.65 ± 0.07 MPa and 0.26 ± 0.15, respectively. Conclusions: A method was proposed to determine corneal biomechanical parameters based on the results of ORA measurements. The magnitude of the corneal biomechanical parameters calculated according to our method was reasonable. |
format | Online Article Text |
id | pubmed-9043460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-90434602022-04-28 Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements Qin, Xiao Tian, Lei Zhang, Hui Zhang, Di Jie, Ying Zhang, Hai-Xia Li, Lin Front Bioeng Biotechnol Bioengineering and Biotechnology Purpose: The Ocular Response Analyzer (ORA) is one of the most commonly used devices to measure corneal biomechanics in vivo. Until now, the relationship between the output parameters and corneal typical biomechanical parameters was not clear. Hence, we defined the output parameters of ORA as ORA output parameters. This study aims to propose a method to determine corneal biomechanical parameters based on ORA measurements by finite element simulation and parametric analysis. Methods: Finite element analysis was used to simulate the mechanics process of ORA measurements with different intraocular pressure (IOP), corneal geometrical parameters and corneal biomechanical parameters. A simplified geometrical optics model was built to simulate the optical process of the measurements to extract ORA output parameters. After that, 70% of the simulated data was used to establish the quantitative relationship between corneal biomechanical parameters and ORA output parameters by parametric analysis and 30% of the simulated data was used to validate the established model. Besides, ten normal subjects were included to evaluate the normal range of corneal biomechanical parameters calculated from ORA. Results: The quantitative relationship between corneal biomechanical parameters and ORA output parameters is established by combining parametric analysis with finite element simulation. The elastic modulus (E) and relaxation limit (G (∞)) of the ten normal subjects were 0.65 ± 0.07 MPa and 0.26 ± 0.15, respectively. Conclusions: A method was proposed to determine corneal biomechanical parameters based on the results of ORA measurements. The magnitude of the corneal biomechanical parameters calculated according to our method was reasonable. Frontiers Media S.A. 2022-04-13 /pmc/articles/PMC9043460/ /pubmed/35497338 http://dx.doi.org/10.3389/fbioe.2022.862947 Text en Copyright © 2022 Qin, Tian, Zhang, Zhang, Jie, Zhang and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Qin, Xiao Tian, Lei Zhang, Hui Zhang, Di Jie, Ying Zhang, Hai-Xia Li, Lin Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title | Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title_full | Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title_fullStr | Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title_full_unstemmed | Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title_short | Determine Corneal Biomechanical Parameters by Finite Element Simulation and Parametric Analysis Based on ORA Measurements |
title_sort | determine corneal biomechanical parameters by finite element simulation and parametric analysis based on ora measurements |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9043460/ https://www.ncbi.nlm.nih.gov/pubmed/35497338 http://dx.doi.org/10.3389/fbioe.2022.862947 |
work_keys_str_mv | AT qinxiao determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT tianlei determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT zhanghui determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT zhangdi determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT jieying determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT zhanghaixia determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements AT lilin determinecornealbiomechanicalparametersbyfiniteelementsimulationandparametricanalysisbasedonorameasurements |