Cargando…
Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring
Point-of-care (POC) quantification of antibody responses against SARS-CoV-2 spike protein can enable decentralized monitoring of immune responses after infection or vaccination. We evaluated a novel POC microfluidic cartridge-based device (ViroTrack Sero COVID-19 Total Ab) for quantitative detection...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9045215/ https://www.ncbi.nlm.nih.gov/pubmed/35357223 http://dx.doi.org/10.1128/spectrum.00396-22 |
_version_ | 1784695264797261824 |
---|---|
author | Moeller, Maria E. Engsig, Frederik N. Bade, Melanie Fock, Jeppe Pah, Pearlyn Soerensen, Anna Louise Bang, Didi Donolato, Marco Benfield, Thomas |
author_facet | Moeller, Maria E. Engsig, Frederik N. Bade, Melanie Fock, Jeppe Pah, Pearlyn Soerensen, Anna Louise Bang, Didi Donolato, Marco Benfield, Thomas |
author_sort | Moeller, Maria E. |
collection | PubMed |
description | Point-of-care (POC) quantification of antibody responses against SARS-CoV-2 spike protein can enable decentralized monitoring of immune responses after infection or vaccination. We evaluated a novel POC microfluidic cartridge-based device (ViroTrack Sero COVID-19 Total Ab) for quantitative detection of total antibodies against SARS-CoV-2 spike trimeric spike protein compared to standard laboratory chemiluminescence (CLIA)-based tests. Antibody responses of 101 individuals were measured on capillary blood, venous whole blood, plasma, and diluted plasma samples directly on the POC. Results were available within 7 min. As the reference, plasma samples were analyzed on DiaSorin LIAISON XL CLIA analyzer using LIAISON SARS-CoV-2 IgM, LIAISON SARS-CoV-2 S1/S2 IgG, and LIAISON SARS-CoV-2 TrimericS IgG assays. The Spearman rank’s correlation coefficient between ViroTrack Sero COVID-19 Total Ab and LIAISON SARS-CoV-2 S1/S2 IgG and LIAISON SARS-CoV-2 TrimericS IgG assays was found to be 0.83 and 0.89, respectively. ViroTrack Sero COVID-19 Total Ab showed high correlation between the different matrixes. Agreement for determination of samples of >230 binding antibody units (BAU)/mL on POC and CLIA methods is estimated to be around 90%. ViroTrack Sero Covid Total Ab is a rapid and simple-to-use POC test with high sensitivity and correlation of numerical results expressed in BAU/mL compared to those of a commercial CLIA assay. IMPORTANCE Serological testing is an important diagnostic support tool in the fight against COVID-19. So far, serological testing has been performed on either lateral flow assays, which perform only qualitatively and can be difficult for the individual to read, or standard laboratory assays, which are time- and resource-consuming. The purpose of the study was to evaluate the performance of a new POC microfluidic cartridge-based device based on immunomagnetic agglutination assay that can provide an accurate numerical quantification of the total antibodies within only 7 min from a single drop of capillary blood. We demonstrated a high level of correlation between the POC and the two CLIA laboratory-based immunoassays from Diasorin, thus allowing a potentially wider use of quantitative serology tests in the COVID-19 pandemic. |
format | Online Article Text |
id | pubmed-9045215 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Society for Microbiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-90452152022-04-28 Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring Moeller, Maria E. Engsig, Frederik N. Bade, Melanie Fock, Jeppe Pah, Pearlyn Soerensen, Anna Louise Bang, Didi Donolato, Marco Benfield, Thomas Microbiol Spectr Research Article Point-of-care (POC) quantification of antibody responses against SARS-CoV-2 spike protein can enable decentralized monitoring of immune responses after infection or vaccination. We evaluated a novel POC microfluidic cartridge-based device (ViroTrack Sero COVID-19 Total Ab) for quantitative detection of total antibodies against SARS-CoV-2 spike trimeric spike protein compared to standard laboratory chemiluminescence (CLIA)-based tests. Antibody responses of 101 individuals were measured on capillary blood, venous whole blood, plasma, and diluted plasma samples directly on the POC. Results were available within 7 min. As the reference, plasma samples were analyzed on DiaSorin LIAISON XL CLIA analyzer using LIAISON SARS-CoV-2 IgM, LIAISON SARS-CoV-2 S1/S2 IgG, and LIAISON SARS-CoV-2 TrimericS IgG assays. The Spearman rank’s correlation coefficient between ViroTrack Sero COVID-19 Total Ab and LIAISON SARS-CoV-2 S1/S2 IgG and LIAISON SARS-CoV-2 TrimericS IgG assays was found to be 0.83 and 0.89, respectively. ViroTrack Sero COVID-19 Total Ab showed high correlation between the different matrixes. Agreement for determination of samples of >230 binding antibody units (BAU)/mL on POC and CLIA methods is estimated to be around 90%. ViroTrack Sero Covid Total Ab is a rapid and simple-to-use POC test with high sensitivity and correlation of numerical results expressed in BAU/mL compared to those of a commercial CLIA assay. IMPORTANCE Serological testing is an important diagnostic support tool in the fight against COVID-19. So far, serological testing has been performed on either lateral flow assays, which perform only qualitatively and can be difficult for the individual to read, or standard laboratory assays, which are time- and resource-consuming. The purpose of the study was to evaluate the performance of a new POC microfluidic cartridge-based device based on immunomagnetic agglutination assay that can provide an accurate numerical quantification of the total antibodies within only 7 min from a single drop of capillary blood. We demonstrated a high level of correlation between the POC and the two CLIA laboratory-based immunoassays from Diasorin, thus allowing a potentially wider use of quantitative serology tests in the COVID-19 pandemic. American Society for Microbiology 2022-03-31 /pmc/articles/PMC9045215/ /pubmed/35357223 http://dx.doi.org/10.1128/spectrum.00396-22 Text en Copyright © 2022 Moeller et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Moeller, Maria E. Engsig, Frederik N. Bade, Melanie Fock, Jeppe Pah, Pearlyn Soerensen, Anna Louise Bang, Didi Donolato, Marco Benfield, Thomas Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title | Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title_full | Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title_fullStr | Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title_full_unstemmed | Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title_short | Rapid Quantitative Point-Of-Care Diagnostic Test for Post COVID-19 Vaccination Antibody Monitoring |
title_sort | rapid quantitative point-of-care diagnostic test for post covid-19 vaccination antibody monitoring |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9045215/ https://www.ncbi.nlm.nih.gov/pubmed/35357223 http://dx.doi.org/10.1128/spectrum.00396-22 |
work_keys_str_mv | AT moellermariae rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT engsigfrederikn rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT bademelanie rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT fockjeppe rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT pahpearlyn rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT soerensenannalouise rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT bangdidi rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT donolatomarco rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring AT benfieldthomas rapidquantitativepointofcarediagnostictestforpostcovid19vaccinationantibodymonitoring |