Cargando…

Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images

PURPOSE: Accurate lesion segmentation is a prerequisite for radiomic feature extraction. It helps to reduce the features variability so as to improve the reporting quality of radiomics study. In this research, we aimed to conduct a radiomic feature reproducibility test of inter-/intra-observer delin...

Descripción completa

Detalles Bibliográficos
Autores principales: Duan, Jinghao, Qiu, Qingtao, Zhu, Jian, Shang, Dongping, Dou, Xue, Sun, Tao, Yin, Yong, Meng, Xiangjuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9047864/
https://www.ncbi.nlm.nih.gov/pubmed/35494061
http://dx.doi.org/10.3389/fonc.2022.881931
_version_ 1784695816365015040
author Duan, Jinghao
Qiu, Qingtao
Zhu, Jian
Shang, Dongping
Dou, Xue
Sun, Tao
Yin, Yong
Meng, Xiangjuan
author_facet Duan, Jinghao
Qiu, Qingtao
Zhu, Jian
Shang, Dongping
Dou, Xue
Sun, Tao
Yin, Yong
Meng, Xiangjuan
author_sort Duan, Jinghao
collection PubMed
description PURPOSE: Accurate lesion segmentation is a prerequisite for radiomic feature extraction. It helps to reduce the features variability so as to improve the reporting quality of radiomics study. In this research, we aimed to conduct a radiomic feature reproducibility test of inter-/intra-observer delineation variability in hepatocellular carcinoma using 3D-CT images, 4D-CT images and multiple-parameter MR images. MATERIALS AND METHODS: For this retrospective study, 19 HCC patients undergoing 3D-CT, 4D-CT and multiple-parameter MR scans were included in this study. The gross tumor volume (GTV) was independently delineated twice by two observers based on contrast-enhanced computed tomography (CECT), maximum intensity projection (MIP), LAVA-Flex, T2W FRFSE and DWI-EPI images. We also delineated the peritumoral region, which was defined as 0 to 5 mm radius surrounding the GTV. 107 radiomic features were automatically extracted from CECT images using 3D-Slicer software. Quartile coefficient of dispersion (QCD) and intraclass correlation coefficient (ICC) were applied to assess the variability of each radiomic feature. QCD<10% and ICC≥0.75 were considered small variations and excellent reliability. Finally, the principal component analysis (PCA) was used to test the feasibility of dimensionality reduction. RESULTS: For tumor tissues, the numbers of radiomic features with QCD<10% indicated no obvious inter-/intra-observer differences or discrepancies in 3D-CT, 4D-CT and multiple-parameter MR delineation. However, the number of radiomic features (mean 89) with ICC≥0.75 was the highest in the multiple-parameter MR group, followed by the 3DCT group (mean 77) and the MIP group (mean 73). The peritumor tissues also showed similar results. A total of 15 and 7 radiomic features presented excellent reproducibility and small variation in tumor and peritumoral tissues, respectively. Two robust features showed excellent reproducibility and small variation in tumor and peritumoral tissues. In addition, the values of the two features both represented statistically significant differences among tumor and peritumoral tissues (P<0.05). The PCA results indicated that the first seven principal components could preserve at least 90% of the variance of the original set of features. CONCLUSION: Delineation on multiple-parameter MR images could help to improve the reproducibility of the HCC CT radiomic features and weaken the inter-/intra-observer influence.
format Online
Article
Text
id pubmed-9047864
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90478642022-04-29 Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images Duan, Jinghao Qiu, Qingtao Zhu, Jian Shang, Dongping Dou, Xue Sun, Tao Yin, Yong Meng, Xiangjuan Front Oncol Oncology PURPOSE: Accurate lesion segmentation is a prerequisite for radiomic feature extraction. It helps to reduce the features variability so as to improve the reporting quality of radiomics study. In this research, we aimed to conduct a radiomic feature reproducibility test of inter-/intra-observer delineation variability in hepatocellular carcinoma using 3D-CT images, 4D-CT images and multiple-parameter MR images. MATERIALS AND METHODS: For this retrospective study, 19 HCC patients undergoing 3D-CT, 4D-CT and multiple-parameter MR scans were included in this study. The gross tumor volume (GTV) was independently delineated twice by two observers based on contrast-enhanced computed tomography (CECT), maximum intensity projection (MIP), LAVA-Flex, T2W FRFSE and DWI-EPI images. We also delineated the peritumoral region, which was defined as 0 to 5 mm radius surrounding the GTV. 107 radiomic features were automatically extracted from CECT images using 3D-Slicer software. Quartile coefficient of dispersion (QCD) and intraclass correlation coefficient (ICC) were applied to assess the variability of each radiomic feature. QCD<10% and ICC≥0.75 were considered small variations and excellent reliability. Finally, the principal component analysis (PCA) was used to test the feasibility of dimensionality reduction. RESULTS: For tumor tissues, the numbers of radiomic features with QCD<10% indicated no obvious inter-/intra-observer differences or discrepancies in 3D-CT, 4D-CT and multiple-parameter MR delineation. However, the number of radiomic features (mean 89) with ICC≥0.75 was the highest in the multiple-parameter MR group, followed by the 3DCT group (mean 77) and the MIP group (mean 73). The peritumor tissues also showed similar results. A total of 15 and 7 radiomic features presented excellent reproducibility and small variation in tumor and peritumoral tissues, respectively. Two robust features showed excellent reproducibility and small variation in tumor and peritumoral tissues. In addition, the values of the two features both represented statistically significant differences among tumor and peritumoral tissues (P<0.05). The PCA results indicated that the first seven principal components could preserve at least 90% of the variance of the original set of features. CONCLUSION: Delineation on multiple-parameter MR images could help to improve the reproducibility of the HCC CT radiomic features and weaken the inter-/intra-observer influence. Frontiers Media S.A. 2022-04-14 /pmc/articles/PMC9047864/ /pubmed/35494061 http://dx.doi.org/10.3389/fonc.2022.881931 Text en Copyright © 2022 Duan, Qiu, Zhu, Shang, Dou, Sun, Yin and Meng https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Duan, Jinghao
Qiu, Qingtao
Zhu, Jian
Shang, Dongping
Dou, Xue
Sun, Tao
Yin, Yong
Meng, Xiangjuan
Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title_full Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title_fullStr Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title_full_unstemmed Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title_short Reproducibility for Hepatocellular Carcinoma CT Radiomic Features: Influence of Delineation Variability Based on 3D-CT, 4D-CT and Multiple-Parameter MR Images
title_sort reproducibility for hepatocellular carcinoma ct radiomic features: influence of delineation variability based on 3d-ct, 4d-ct and multiple-parameter mr images
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9047864/
https://www.ncbi.nlm.nih.gov/pubmed/35494061
http://dx.doi.org/10.3389/fonc.2022.881931
work_keys_str_mv AT duanjinghao reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT qiuqingtao reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT zhujian reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT shangdongping reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT douxue reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT suntao reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT yinyong reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages
AT mengxiangjuan reproducibilityforhepatocellularcarcinomactradiomicfeaturesinfluenceofdelineationvariabilitybasedon3dct4dctandmultipleparametermrimages