Cargando…
Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study
Knee replacement operations are common, highly successful procedures that are increasing in frequency. The COVID-19 pandemic has emphasized the need for innovative care pathways that reduce face-to-face appointments. We report on the impact of introducing a wearable sensor for pre- and postoperative...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of Bone and Joint Surgery, Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9049033/ https://www.ncbi.nlm.nih.gov/pubmed/35506018 http://dx.doi.org/10.2106/JBJS.OA.21.00154 |
_version_ | 1784696055176101888 |
---|---|
author | Cooper, D.M. Bhuskute, N. Walsh, G. |
author_facet | Cooper, D.M. Bhuskute, N. Walsh, G. |
author_sort | Cooper, D.M. |
collection | PubMed |
description | Knee replacement operations are common, highly successful procedures that are increasing in frequency. The COVID-19 pandemic has emphasized the need for innovative care pathways that reduce face-to-face appointments. We report on the impact of introducing a wearable sensor for pre- and postoperative rehabilitation of 21 knee replacement patients at 2 hospitals in the U.K. METHODS: The sensor (BPMpathway; 270 Vision) was provided during joint school prior to knee replacement and stayed with the patient until a maximum of 9 weeks post-surgery. Participant progress and exercise were monitored remotely, with exercise regimens altered as required. Participants and clinicians could communicate remotely via the device. RESULTS: The median range of motion during the first week post-surgery was 63° (interquartile range [IQR] = 21°) and increased to 136° (IQR = 16°) by week 7. The rate of participant compliance with exercises using the device was 32.3% for thrice-daily compliance and 52.4% for once-daily compliance. The 2-way communication channel was well utilized by both participants and clinicians. We report a 35.7% reduction in face-to-face physiotherapy appointments compared with standard practice. Finally, >80% of users who completed the feedback questionnaire reported a positive experience using the device, finding it easy to understand and reporting that it motivated them to perform their exercises. CONCLUSIONS: The use of BPMpathway was well received, effective, and reduced face-to-face physiotherapy appointments. CLINICAL RELEVANCE: Remote monitoring can reduce the burden to the outpatient physiotherapy service by supporting the post-COVID-19 surgical service recovery plans of the National Health Service and allowing patients to recuperate at home. |
format | Online Article Text |
id | pubmed-9049033 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Journal of Bone and Joint Surgery, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-90490332022-05-02 Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study Cooper, D.M. Bhuskute, N. Walsh, G. JB JS Open Access Scientific Articles Knee replacement operations are common, highly successful procedures that are increasing in frequency. The COVID-19 pandemic has emphasized the need for innovative care pathways that reduce face-to-face appointments. We report on the impact of introducing a wearable sensor for pre- and postoperative rehabilitation of 21 knee replacement patients at 2 hospitals in the U.K. METHODS: The sensor (BPMpathway; 270 Vision) was provided during joint school prior to knee replacement and stayed with the patient until a maximum of 9 weeks post-surgery. Participant progress and exercise were monitored remotely, with exercise regimens altered as required. Participants and clinicians could communicate remotely via the device. RESULTS: The median range of motion during the first week post-surgery was 63° (interquartile range [IQR] = 21°) and increased to 136° (IQR = 16°) by week 7. The rate of participant compliance with exercises using the device was 32.3% for thrice-daily compliance and 52.4% for once-daily compliance. The 2-way communication channel was well utilized by both participants and clinicians. We report a 35.7% reduction in face-to-face physiotherapy appointments compared with standard practice. Finally, >80% of users who completed the feedback questionnaire reported a positive experience using the device, finding it easy to understand and reporting that it motivated them to perform their exercises. CONCLUSIONS: The use of BPMpathway was well received, effective, and reduced face-to-face physiotherapy appointments. CLINICAL RELEVANCE: Remote monitoring can reduce the burden to the outpatient physiotherapy service by supporting the post-COVID-19 surgical service recovery plans of the National Health Service and allowing patients to recuperate at home. Journal of Bone and Joint Surgery, Inc. 2022-04-27 /pmc/articles/PMC9049033/ /pubmed/35506018 http://dx.doi.org/10.2106/JBJS.OA.21.00154 Text en Copyright © 2022 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Scientific Articles Cooper, D.M. Bhuskute, N. Walsh, G. Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title | Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title_full | Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title_fullStr | Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title_full_unstemmed | Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title_short | Exploring the Impact and Acceptance of Wearable Sensor Technology for Pre- and Postoperative Rehabilitation in Knee Replacement Patients: A U.K.-Based Pilot Study |
title_sort | exploring the impact and acceptance of wearable sensor technology for pre- and postoperative rehabilitation in knee replacement patients: a u.k.-based pilot study |
topic | Scientific Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9049033/ https://www.ncbi.nlm.nih.gov/pubmed/35506018 http://dx.doi.org/10.2106/JBJS.OA.21.00154 |
work_keys_str_mv | AT cooperdm exploringtheimpactandacceptanceofwearablesensortechnologyforpreandpostoperativerehabilitationinkneereplacementpatientsaukbasedpilotstudy AT bhuskuten exploringtheimpactandacceptanceofwearablesensortechnologyforpreandpostoperativerehabilitationinkneereplacementpatientsaukbasedpilotstudy AT walshg exploringtheimpactandacceptanceofwearablesensortechnologyforpreandpostoperativerehabilitationinkneereplacementpatientsaukbasedpilotstudy |