Cargando…

Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics

The electrical spark discharge method was used to prepare graphene copper nanocomposite (GNS-Cu) colloids under normal temperature and pressure. Cu and graphite were mixed in deionized water at a Cu : C mass ratio of 9 : 1 (99% purity), and the mixture was used to produce composite rods as the elect...

Descripción completa

Detalles Bibliográficos
Autores principales: Tseng, Kuo-Hsiung, Huang, Chang-Hsiang, Ku, Hsueh-Chien, Tien, Der-Chi, Stobinski, Leszek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9049821/
https://www.ncbi.nlm.nih.gov/pubmed/35497012
http://dx.doi.org/10.1039/d2ra01456d
_version_ 1784696226599403520
author Tseng, Kuo-Hsiung
Huang, Chang-Hsiang
Ku, Hsueh-Chien
Tien, Der-Chi
Stobinski, Leszek
author_facet Tseng, Kuo-Hsiung
Huang, Chang-Hsiang
Ku, Hsueh-Chien
Tien, Der-Chi
Stobinski, Leszek
author_sort Tseng, Kuo-Hsiung
collection PubMed
description The electrical spark discharge method was used to prepare graphene copper nanocomposite (GNS-Cu) colloids under normal temperature and pressure. Cu and graphite were mixed in deionized water at a Cu : C mass ratio of 9 : 1 (99% purity), and the mixture was used to produce composite rods as the electrodes for spark machining. An electrical discharge machine with five settings of pulse cycle turn-on and turn-off times, namely 10–10, 30–30, 50–50, 70–70, and 90–90 μs, was used to prepare five different types of GNS-Cu colloids. The ultraviolet-visible spectroscopy results revealed that the highest absorbance (2.441) was observed when the turn-on and turn-off times were 30–30 μs, indicating that this configuration was most efficient for preparing GNS-Cu colloids. Transmission electron microscopy and X-ray diffraction analysis were also conducted to examine the surface characteristics and crystal structure of GNS-Cu colloids. The transmission electron microscopy results revealed that Cu particles in the GNS-Cu colloids were located within or on top of graphene sheets. The Cu particle size varied with the discharge efficiency, and the lattice spacing of the Cu particles was approximately 0.218 nm. The results of X-ray diffraction analysis revealed that no byproducts were formed from the preparation of GNS-Cu colloids, which had complete crystal structures.
format Online
Article
Text
id pubmed-9049821
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90498212022-04-29 Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics Tseng, Kuo-Hsiung Huang, Chang-Hsiang Ku, Hsueh-Chien Tien, Der-Chi Stobinski, Leszek RSC Adv Chemistry The electrical spark discharge method was used to prepare graphene copper nanocomposite (GNS-Cu) colloids under normal temperature and pressure. Cu and graphite were mixed in deionized water at a Cu : C mass ratio of 9 : 1 (99% purity), and the mixture was used to produce composite rods as the electrodes for spark machining. An electrical discharge machine with five settings of pulse cycle turn-on and turn-off times, namely 10–10, 30–30, 50–50, 70–70, and 90–90 μs, was used to prepare five different types of GNS-Cu colloids. The ultraviolet-visible spectroscopy results revealed that the highest absorbance (2.441) was observed when the turn-on and turn-off times were 30–30 μs, indicating that this configuration was most efficient for preparing GNS-Cu colloids. Transmission electron microscopy and X-ray diffraction analysis were also conducted to examine the surface characteristics and crystal structure of GNS-Cu colloids. The transmission electron microscopy results revealed that Cu particles in the GNS-Cu colloids were located within or on top of graphene sheets. The Cu particle size varied with the discharge efficiency, and the lattice spacing of the Cu particles was approximately 0.218 nm. The results of X-ray diffraction analysis revealed that no byproducts were formed from the preparation of GNS-Cu colloids, which had complete crystal structures. The Royal Society of Chemistry 2022-04-28 /pmc/articles/PMC9049821/ /pubmed/35497012 http://dx.doi.org/10.1039/d2ra01456d Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Tseng, Kuo-Hsiung
Huang, Chang-Hsiang
Ku, Hsueh-Chien
Tien, Der-Chi
Stobinski, Leszek
Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title_full Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title_fullStr Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title_full_unstemmed Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title_short Parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
title_sort parameter configuration of the electrical spark discharge method for preparing graphene copper nanocomposite colloids and the analysis of product characteristics
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9049821/
https://www.ncbi.nlm.nih.gov/pubmed/35497012
http://dx.doi.org/10.1039/d2ra01456d
work_keys_str_mv AT tsengkuohsiung parameterconfigurationoftheelectricalsparkdischargemethodforpreparinggraphenecoppernanocompositecolloidsandtheanalysisofproductcharacteristics
AT huangchanghsiang parameterconfigurationoftheelectricalsparkdischargemethodforpreparinggraphenecoppernanocompositecolloidsandtheanalysisofproductcharacteristics
AT kuhsuehchien parameterconfigurationoftheelectricalsparkdischargemethodforpreparinggraphenecoppernanocompositecolloidsandtheanalysisofproductcharacteristics
AT tienderchi parameterconfigurationoftheelectricalsparkdischargemethodforpreparinggraphenecoppernanocompositecolloidsandtheanalysisofproductcharacteristics
AT stobinskileszek parameterconfigurationoftheelectricalsparkdischargemethodforpreparinggraphenecoppernanocompositecolloidsandtheanalysisofproductcharacteristics